Refractive Index-Based Detection of Gradient Elution Liquid Chromatography using Chip-Integrated Microring Resonator Arrays

被引:32
|
作者
Wade, James H. [1 ]
Bailey, Ryan C. [1 ]
机构
[1] Univ Illinois, Dept Chem, Urbana, IL 61801 USA
基金
美国国家科学基金会; 美国国家卫生研究院;
关键词
SURFACE-PLASMON RESONANCE; LIGHT-SCATTERING; RING RESONATORS; SENSITIVITY; ABSORBENCY; SENSOR;
D O I
10.1021/ac4035828
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Refractive index-based sensors offer attractive characteristics as nondestructive and universal detectors for liquid chromatographic separations, but a small dynamic range and sensitivity to minor thermal perturbations limit the utility of commercial RI detectors for many potential applications, especially those requiring the use of gradient elutions. As such, RI detectors find use almost exclusively in sample abundant, isocratic separations when interfaced with high-performance liquid chromatography. Silicon photonic microring resonators are refractive index-sensitive optical devices that feature good sensitivity and tremendous dynamic range. The large dynamic range of microring resonators allows the sensors to function across a wide spectrum of refractive indices, such as that encountered when moving from an aqueous to organic mobile phase during a gradient elution, a key analytical advantage not supported in commercial RI detectors. Microrings are easily configured into sensor arrays, and chip-integrated control microrings enable real-time corrections of thermal drift. Thermal controls allow for analyses at any temperature and, in the absence of rigorous temperature control, obviates extended detector equilibration wait times. Herein, proof of concept isocratic and gradient elution separations were performed using well-characterized model analytes (e.g., caffeine, ibuprofen) in both neat buffer and more complex sample matrices. These experiments demonstrate the ability of microring arrays to perform isocratic and gradient elutions under ambient conditions, avoiding two major limitations of commercial RI-based detectors and maintaining comparable bulk RI sensitivity. Further benefit may be realized in the future through selective surface functionalization to impart degrees of postcolumn (bio)molecular specificity at the detection phase of a separation. The chip-based and microscale nature of microring resonators also make it an attractive potential detection technology that could be integrated within lab-on-a-chip and microfluidic separation devices.
引用
收藏
页码:913 / 919
页数:7
相关论文
共 38 条
  • [1] Hyphenating temperature gradient elution with refractive index detection through temperature-responsive liquid chromatography
    Bandini, Elena
    Wicht, Kristina
    Ampe, Adriaan
    Baert, Mathijs
    Eghbali, Hamed
    Lynen, Frederic
    ANALYTICA CHIMICA ACTA, 2022, 1231
  • [2] Microfabricated refractive index gradient based detector for reversed-phase liquid chromatography with mobile phase gradient elution
    McBrady, AD
    Synovec, RE
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1105 (1-2) : 2 - 10
  • [3] Multiplexed cancer biomarker detection using chip-integrated silicon photonic sensor arrays
    Washburn, Adam L.
    Shia, Winnie W.
    Lenkeit, Kimberly A.
    Lee, So-Hyun
    Bailey, Ryan C.
    ANALYST, 2016, 141 (18) : 5358 - 5365
  • [4] High-Sensitivity Refractive Index-Based Microring Resonator All-Optical Sensor with Fano Resonance Spectrum
    Azrisham, Nurul Fathinah
    Aman, Mohammad Amirul Hairol
    Nazmi, Ahmad Nadzimuddin
    Noorden, Ahmad Fakhrurrazi Ahmad
    JURNAL FIZIK MALAYSIA, 2024, 45 (01): : 10132 - 10143
  • [5] Single-particle detection using high-refractive index film coated in microring resonator
    Zhang, Zhi-Hong
    Li, Mu-Neng
    Gui, Feng-Ji
    Shang, Si-Hui
    HOLOGRAPHY, DIFFRACTIVE OPTICS, AND APPLICATIONS VIII, 2018, 10818
  • [6] On-chip integrated differential optical microring refractive index sensing platform based on a laminar flow scheme
    Kim, Dongwan
    Popescu, Paula
    Harfouche, Mark
    Sendowski, Jacob
    Dimotsantou, Maria-Eleni
    Flagan, Richard C.
    Yariv, Amnon
    OPTICS LETTERS, 2015, 40 (17) : 4106 - 4109
  • [7] EVALUATION OF REFRACTIVE-INDEX ARTIFACTS IN LIQUID-CHROMATOGRAPHIC ABSORBENCY DETECTION - EXTENSION TO NONIDEAL INJECTION AND GRADIENT ELUTION
    EVANS, CE
    MCGUFFIN, VL
    JOURNAL OF CHROMATOGRAPHY, 1990, 503 (01): : 127 - 154
  • [8] REFRACTIVE-INDEX GRADIENT DETECTION OF BIOPOLYMERS SEPARATED BY HIGH-TEMPERATURE LIQUID-CHROMATOGRAPHY
    RENN, CN
    SYNOVEC, RE
    JOURNAL OF CHROMATOGRAPHY, 1991, 536 (1-2): : 289 - 301
  • [10] UNCOUPLING THE EFFECTS OF CONVECTION AND DIFFUSION ON REFRACTIVE-INDEX GRADIENT DETECTION IN HIGH-TEMPERATURE LIQUID-CHROMATOGRAPHY
    LIMA, LR
    SYNOVEC, RE
    ANALYTICAL CHEMISTRY, 1993, 65 (02) : 128 - 134