Characterization of etched electrochemical detection for electrophoresis in micron inner diameter capillaries

被引:8
|
作者
Powell, PR [1 ]
Woods, LA [1 ]
Ewing, AG [1 ]
机构
[1] Penn State Univ, Dept Chem, University Pk, PA 16802 USA
关键词
capillary electrophoresis; carbon fiber electrodes; electrochemical detection;
D O I
10.1002/jssc.200500167
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
An enhanced etched electrochemical (EC) detection technique has been developed for CE in micron inner diameter capillaries. The design improvements allow for better alignment between the capillary bore and the electrode. This new method involves utilizing a carbon fiber microelectrode and etching both the carbon fiber and the detection end of a micrometer-sized inner diameter capillary to limit dead volume and analyte diffusion at the amperometric EC detector. To understand the factors affecting enhanced detector efficiency, a detailed examination of the relationship between detector design and performance has been completed by exploring the effects of varying electrode diameter, tip shape, and size, in addition to the etch length of the capillary outlet. The enhanced detection provides peak efficiencies as high as 75000 theoretical plates and estimated detection limits as low as 40 nM for dopamine. This etched detection method should further facilitate volume-limited sample analysis by CE.
引用
收藏
页码:2540 / 2545
页数:6
相关论文
共 50 条
  • [1] Etched electrochemical detection for electrophoresis in nanometer inner diameter capillaries
    Woods, LA
    Ewing, AG
    CHEMPHYSCHEM, 2003, 4 (02) : 207 - 211
  • [2] Electrophoresis in nanometer inner diameter capillaries with electrochemical detection
    Woods, LA
    Roddy, TP
    Paxon, TL
    Ewing, AG
    ANALYTICAL CHEMISTRY, 2001, 73 (15) : 3687 - 3690
  • [3] Capillary electrophoresis and contactless conductivity detection of ions in narrow inner diameter capillaries
    Mayrhofer, K
    Zemann, AJ
    Schnell, E
    Bonn, GK
    ANALYTICAL CHEMISTRY, 1999, 71 (17) : 3828 - 3833
  • [5] Contactless Conductivity Detection in Capillary Electrophoresis in Combination with Capillaries with Thin Inner Diameter
    Tuma, Petr
    Samcova, Eva
    MODERN ELECTROCHEMICAL METHODS XXXI, 2011, : 168 - 172
  • [6] Analysis of mammalian cell cytoplasm with electrophoresis in nanometer inner diameter capillaries
    Woods, LA
    Powell, PR
    Paxon, TL
    Ewing, AG
    ELECTROANALYSIS, 2005, 17 (13) : 1192 - 1197
  • [7] Electrically assisted sampling across membranes with electrophoresis in nanometer inner diameter capillaries
    Woods, LA
    Gandhi, PU
    Ewing, AG
    ANALYTICAL CHEMISTRY, 2005, 77 (06) : 1819 - 1823
  • [8] Inner surface properties of capillaries for electrophoresis
    Wätzig, H
    Kaupp, S
    Graf, M
    TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 2003, 22 (09) : 588 - 604
  • [9] Characterization of linearly coupled capillaries with various inner diameters in the context of capillary electrophoresis
    Daniel Böhm
    Frank-Michael Matysik
    Monatshefte für Chemie - Chemical Monthly, 2021, 152 : 1053 - 1060
  • [10] Characterization of linearly coupled capillaries with various inner diameters in the context of capillary electrophoresis
    Boehm, Daniel
    Matysik, Frank-Michael
    MONATSHEFTE FUR CHEMIE, 2021, 152 (09): : 1053 - 1060