Intraoperative Measurements and Tools to Assess Stability

被引:14
|
作者
D'Lima, Darryl D. [1 ]
Colwell, Clifford W. [1 ]
机构
[1] Scripps Res Inst, La Jolla, CA 92037 USA
基金
美国国家卫生研究院;
关键词
TOTAL KNEE ARTHROPLASTY; COLLATERAL LIGAMENT LAXITY; FOLLOW-UP; BALANCE; KINEMATICS; RELEASE; FLEXION; SATISFACTION; REPLACEMENT; INSTABILITY;
D O I
10.5435/JAAOS-D-16-00629
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Knee stability is the ability for the joint to maintain an appropriate functional position throughout its range of motion. Knee instability can be defined as excessive laxity during activities of daily living. Intraoperative knee laxity can be affected by implant design, alignment of components, and soft-tissue balancing. Soft-tissue balance is a major contributor to knee instability. Mechanical balancing instruments can be classified as spacer blocks or joint-distraction devices. Conventional wisdom favors rectangular and equal flexion extension gaps. However, knee balance is elusive even with mechanical balanbing instruments. First-generation electronic balancing devices are equivalent in concept to spacer blocks instrumented with force sensors. Second-generation electronic balancing devices are equivalent in concept to mechanical distraction devices instrumented with pressure and displacement sensors. Electronic ligament balancers can be useful in documenting intraoperative knee laxity for quantifiable correlation with postoperative outcomes, thus directly relating postoperative stability to surgical balance, and may predict outcomes and knee stability.
引用
收藏
页码:S29 / S32
页数:4
相关论文
共 50 条
  • [1] Systematic review of measurement tools to assess surgeons' intraoperative cognitive workload
    Dias, R. D.
    Ngo-Howard, M. C.
    Boskovski, M. T.
    Zenati, M. A.
    Yule, S. J.
    BRITISH JOURNAL OF SURGERY, 2018, 105 (05) : 491 - 501
  • [2] Metabolic Stability: Main Enzymes Involved and Best Tools To Assess It
    Laine, Romuald
    CURRENT DRUG METABOLISM, 2008, 9 (09) : 921 - 927
  • [3] Analytical tools to assess the voltage stability of induction-based distributed generators
    Grilo, A. P.
    Meira, P. C. M.
    Vieira, J. C. M.
    Freitas, W.
    Bansal, R. C.
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2012, 36 (01) : 31 - 39
  • [4] A task to assess dynamic visual acuity and a valuation of the stability of its measurements
    Quevedo, Lluisa
    Antonio Aznar-Casanova, Jose
    Merindano, Dolores
    Sole, Joan
    PSICOLOGICA, 2010, 31 (01): : 109 - 128
  • [5] Comparison between intraoperative bleeding score and ROTEM® measurements to assess coagulopathy during major pediatric surgery
    Restin, Tanja
    Schmugge, Markus
    Cushing, Melissa M.
    Haas, Thorsten
    TRANSFUSION AND APHERESIS SCIENCE, 2021, 60 (05)
  • [6] Tools to assess tissue quality
    Neumeister, Veronique M.
    CLINICAL BIOCHEMISTRY, 2014, 47 (4-5) : 280 - 287
  • [7] Intraoperative tools for cerebral bypass surgery
    Giuseppe Esposito
    Luca Regli
    Acta Neurochirurgica, 2018, 160 : 775 - 778
  • [8] Intraoperative tools for cerebral bypass surgery
    Esposito, Giuseppe
    Regli, Luca
    ACTA NEUROCHIRURGICA, 2018, 160 (04) : 775 - 778
  • [9] Intraoperative ultrasound to assess for pancreatic duct injuries
    Hofmann, Luke J.
    Learn, Peter A.
    Cannon, Jeremy W.
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2015, 78 (04): : 888 - 891
  • [10] Intraoperative Torque Test to Assess Syndesmosis Instability
    Gosselin-Papadopoulos, Nayla
    Hebert-Davies, Jonah
    Laflamme, G. Yves
    Beausejour, Marie
    Menard, Jeremie
    Leduc, Stephane
    Nault, Marie-Lyne
    FOOT & ANKLE INTERNATIONAL, 2019, 40 (04) : 408 - 413