Investigation on H-8 VSI architecture for bearing currents mitigation in VFD

被引:0
|
作者
Barater, D. [1 ]
Franceschini, G. [1 ]
Immovilli, F. [2 ]
Lorenzani, E. [2 ]
机构
[1] Univ Parma, DIA Dept Engn & Architecture, Parma, Italy
[2] Univ Modena & Reggio Emilia, DISMI Dept Sci & Methods Engn, Reggio Emilia, Italy
关键词
leakage currents; DC source; H8; inverter; active DC-decoupling devices; common-mode voltage reduction; electric drives;
D O I
暂无
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
This paper assesses the use of a modified three phase VSI topology with additional switches (H8) together with suitable modulation techniques as a mean for common-mode voltage reduction in electric drives with the aim of mitigating the onset of harmful bearing currents. Bearing currents in inverter-fed motors are related to the high dv/dt variation, induced at the motor terminals by the converters. The problem, already known in industry for Si-Based converters, is now aggravated by the use of wide-bandgap devices in More Electric Aircraft applications. This paper evaluates the use H8 topology for mitigating the phenomenon, comparing its performance against the one of a conventional three-phase full-bridge converter, by means simulation and experimental results.