Common carotid artery: Variability of Doppler US velocity measurements

被引:27
|
作者
Meyer, JI [1 ]
Khalil, RM [1 ]
Obuchowski, NA [1 ]
Baus, LK [1 ]
机构
[1] CLEVELAND CLIN FDN, DEPT BIOSTAT & EPIDEMIOL, CLEVELAND, OH 44195 USA
关键词
carotid arteries; flow dynamics; stenosis or obstruction; US;
D O I
10.1148/radiology.204.2.9240517
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To determine if Doppler ultrasound (US) measurements of systolic velocity in the common carotid artery vary markedly with distance from the bifurcation. MATERIALS AND METHODS: Bilateral, insonation angle-corrected velocity was measured with US in the common carotid artery. Measurements were obtained 1, 2, 3, 4, and 5 cm from the carotid artery bifurcation in 20 volunteers (aged 25-43 years) with no history of neurologic or cardiovascular disease. RESULTS: Velocity in the common carotid artery increased with distance (toward the aorta) from the bifurcation (mean increase, 9 cm/sec for each centimeter of distance from the bifurcation, up to the 4-cm distance; P < .001). Velocity increased more rapidly in subjects who were younger (P < .001) and in those with a lower pulse rate (P = .001). CONCLUSION: The distance from the bifurcation at which common carotid artery velocity is measured should be standardized. This may increase the accuracy of the systolic velocity ratio for assessment of internal carotid artery stenosis and decrease some of the reported variability between different centers that perform US of the carotid artery.
引用
收藏
页码:339 / 341
页数:3
相关论文
共 50 条
  • [1] Variability of Doppler velocity measurements in the common carotid artery
    Meyer, JI
    Khalil, RM
    Obuchowski, NA
    Baus, LK
    RADIOLOGY, 1996, 201 : 1127 - 1127
  • [2] Variability of Doppler US measurements along the common carotid artery: Effects on estimates of internal carotid arterial stenosis in patients with angiographically proved disease
    Lee, VS
    Hertzberg, BS
    Workman, MJ
    Smith, TP
    Kliewer, MA
    DeLong, DM
    Carroll, BA
    RADIOLOGY, 2000, 214 (02) : 387 - 392
  • [3] COMMON CAROTID-ARTERY FLOW VELOCITY-MEASUREMENTS IN THE NEWBORN PERIOD WITH PULSED DOPPLER TECHNIQUE
    RAJU, TNK
    GO, M
    RYVA, JC
    SCHMIDT, DJ
    BIOLOGY OF THE NEONATE, 1987, 52 (05): : 241 - 249
  • [4] Duplex Doppler sonography of the carotid artery: Velocity measurements in an artery with contralateral stenosis
    Barr, RG
    Bennett, D
    RADIOLOGY, 1997, 205 : 1704 - 1704
  • [5] Doppler US velocity measurements
    Bluth, EI
    RADIOLOGY, 2002, 223 (03) : 882 - 882
  • [6] COMPARISON OF CAROTID ARTERY BLOOD VELOCITY MEASUREMENTS BY VECTOR AND STANDARD DOPPLER APPROACHES
    Tortoli, Piero
    Lenge, Matteo
    Righi, Daniele
    Ciuti, Gabriele
    Liebgott, Herve
    Ricci, Stefano
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2015, 41 (05): : 1354 - 1362
  • [7] Differences between Doppler angle correction techniques for internal carotid artery velocity measurements
    Polak, JF
    Alessi, JM
    Mccauley, MA
    Bjorn, LA
    White, MC
    RADIOLOGY, 1998, 209P : 341 - 341
  • [8] Internal Carotid Artery Doppler Velocity Measurement Precision
    Beach, Kirk W.
    de Bont, Cora
    JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (12) : 2791 - 2793
  • [9] Variability of Doppler ultrasound measurements along the common carotid arteries and subsequent effects on parameters to assess carotid stenosis in patients with angiographically-proven internal carotid artery disease
    Lee, VS
    Hertzberg, BS
    Workman, MJ
    Smith, TP
    Kliewer, MA
    Carroll, BA
    RADIOLOGY, 1998, 209P : 340 - 340
  • [10] Changes in Internal Carotid Artery Doppler Velocity Measurements With Different Angles of Insonation A Pilot Study
    Campbell, Kari A.
    Kupinski, Ann Marie
    Miele, Frank R.
    Silva, Philip F.
    Zierler, R. Eugene
    JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (09) : 1937 - 1948