The effect of thermocycling on the bonding of different restorative materials to access opening through porcelain fused to metal restorations

被引:6
|
作者
AL-Moaleem, Mohammed M. [2 ]
Shah, Farhan Khalid [2 ]
Khan, Nausheen Saied [3 ]
Porwal, Amit [1 ]
机构
[1] Pacific Dent Coll & Hosp, Dept Prosthodont, Debari 313024, Udaipur, India
[2] King Khalid Univ, Dept Prosthodont, Coll Dent, Abha, Saudi Arabia
[3] Kings Coll London, London, England
来源
JOURNAL OF ADVANCED PROSTHODONTICS | 2011年 / 3卷 / 04期
关键词
Porcelain fused to metal restorations; Restorative dental materials; Thermocycling effect; EXISTING CROWNS; RESTORING TEETH; MATERIAL USAGE; MICROLEAKAGE; STRENGTH; PREVENTION; COMPOSITE; IONOMERS; LEAKAGE;
D O I
10.4047/jap.2011.3.4.186
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Porcelain fused to metal (PFM) crowns provide the best treatment option for teeth that have a large or defective restoration. More than 20% of teeth with PFM crowns or bridges require non-surgical root canal treatment (NSRCT). This may be due to the effect of restorative procedures and the possible leakage of bacteria and or their by-products, which leads to the demise of the tooth pulp. Thus, this study was planned to compare the ability of the restorative materials to seal perforated PFM specimens. MATERIALS AND METHODS. The study evaluates the ability of amalgam, composite or compomer restorative materials to close perforated PFM specimen's in-vitro. Ninety PFM specimens were constructed using Ni-Cr alloys and feldspathic porcelain, and then they were divided into 3 groups: amalgam (A), composite + Exite adhesive bond (B) and compomer + Syntac adhesive bond (C). All the PFM samples were embedded in an acrylic block to provide complete sealing of the hole from the bottom side. After the aging period, each group was further divided into 3 equal subgroups according to the thermocycling period (one week for 70 cycles, one month for 300 cycles and three months for 900 cycles). Each subgroup was put into containers containing dye (Pelikan INK), one maintained at 5 degrees C and the other at 55 degrees C each cycle for 30 sec time. The data obtained was analyzed by SPSS, 2006 using one way ANOVA test and student t-test and significant difference level at (P<.01). RESULTS. The depth of dye penetration was measured at the interfaces of PFM and filling materials using Co-ordinate Vernier Microscope. The lowest levels of the dye penetration for the three groups, as well as subgroups were during the first week. The values of dye leakage had significantly increased by time intervals in subgroups A and C. CONCLUSION. It was seen that amalgam showed higher leakage than composite while compomer showed the lowest level of leakage. [J Adv Prosthodont 2011;3:186-9]
引用
收藏
页码:186 / 189
页数:4
相关论文
共 16 条
  • [1] Effect of different production techniques on the color of porcelain-fused-to-titanium restorations
    Korkmaz, Cumhur
    HELIYON, 2024, 10 (03)
  • [2] Effect of thermocycling on shear bond strength and mode of failure of ceramic orthodontic brackets bonded to different porcelain restorations
    Kang, Sang-Wook
    Son, Woo-Sung
    Park, Soo-Byung
    Kim, Seong-Sik
    KOREAN JOURNAL OF ORTHODONTICS, 2009, 39 (04) : 225 - 233
  • [3] AN IN VITRO STUDY OF THE EFFECT OF DIFFERENT RESTORATIVE MATERIALS ON THE RELIABILITY OF A VENEERING PORCELAIN
    Anderson, Matthew R.
    Chung, Kwok-Hung
    Flinn, Brian D.
    Raigrodski, Ariel J.
    JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (06): : 521 - 528
  • [4] Bonding of hybrid composite resin to the surface of gold-alloy used in porcelain-fused-to-metal restorations
    Vallittu, PK
    JOURNAL OF ORAL REHABILITATION, 1997, 24 (08) : 560 - 567
  • [5] The effect of space setting values and restorative block materials on the bonding of metal-free CAD/CAM onlay restorations
    Tokita, Chie
    Maeno, Masahiko
    Nara, Yoichiro
    DENTAL MATERIALS JOURNAL, 2021, 40 (04) : 994 - 1006
  • [6] Effect of Firing Temperature at the Porcelain-Metal Alloy Interface in Porcelain-Fused-to-Metal Restorations. A SEM/EDS Study
    Tripathi, Arvind
    Bagchi, Soumyojeet
    Singh, Juhi
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2018, 27 (04): : 355 - 360
  • [7] The Effect of Cooling Times on the Bonding Between Porcelain and Metal Alloys Fabricated by Different Techniques: In Vitro Study
    Unal, Emine
    Tugut, Faik
    JOURNAL OF ADVANCED ORAL RESEARCH, 2022, 13 (01) : 69 - 77
  • [8] AN INVITRO STUDY OF THE EFFECT ENDODONTIC ACCESS PREPARATION HAS UPON THE RETENTION OF PORCELAIN FUSED TO METAL CROWNS OF MAXILLARY CENTRAL INCISORS
    MCMULLEN, AF
    HIMEL, VT
    SARKAR, NK
    JOURNAL OF ENDODONTICS, 1989, 15 (04) : 154 - 156
  • [9] Effect of Cervical Margin Relocation With Different Injectable Restorative Materials on Fracture Resistance of Molars Received MOD CAD/CAM Onlay Restorations
    Roshdy, Basema N.
    Eltoukhy, Radwa I.
    Ali, Ashraf I.
    Mahmoud, Salah Hasab
    JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2025,
  • [10] The effect of all-ceramic and porcelain-fused-to-metal restorations on marginal peri-implant soft tissue color:: A randomized controlled clinical trial
    Jung, Ronald E.
    Holderegger, Claudia
    Sailer, Irena
    Khraisat, Ameen
    Suter, Ana
    Haemmerle, Christoph H. F.
    INTERNATIONAL JOURNAL OF PERIODONTICS & RESTORATIVE DENTISTRY, 2008, 28 (04) : 357 - 365