On behalf of the German Ministry for Environment, Nature Conservation and Nuclear Safety the Deutsche Gesellschaft fur Internationale Zusammenarbeit (GIZ) GmbH has implemented projects at Chinese and Indian manufacturers of air conditioners within the framework of the International Climate Initiative. The GIZ programme Proklima implemented these projects and based on the progress so far, this study presents an overview of the costs and greenhouse gas emissions reduction cost-effectiveness of using various alternative refrigerants in Article- 5-countries. The study identifies all of the areas where cost implications exist for the introduction of R290 and compares them with the cost for existing R22 or new R410A developments. In addition, the lifetime emissions of such air conditioners are approximated and based on this, the cost-effectiveness of emissions reductions is estimated.
引用
收藏
页码:2704 / 2711
页数:8
相关论文
共 50 条
  • [1] The first 100 000 HC-290 split air conditioners in India
    Rajadhyaksha, D.
    Wadia, B. J.
    Acharekar, Abhijit A.
    Colbourne, D.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 60 : 289 - 296
  • [2] SIMULATED PERFORMANCE OF HC-290 IN AIR CONDITIONERS
    Padalkar, A. S.
    Mali, K. V.
    Devotta, S.
    23RD IIR INTERNATIONAL CONGRESS OF REFRIGERATION, 2011, 23 : 4011 - +
  • [3] THE FIRST 60,000 HC-290 SPLIT AIR CONDITIONERS IN INDIA
    Rajadhyaksha, D.
    Wadia, B. J.
    Colbourne, D.
    11TH IIR GUSTAV LORENTZEN CONFERENCE ON NATURAL REFRIGERANTS (2014): NATURAL REFRIGERANTS AND ENVIRONMENTAL PROTECTION, 2014, : 169 - 177
  • [4] Theoretical and simulation analysis for R290 leakage from split-type air conditioners
    Ning, Qian
    He, Guogeng
    Li, Baofeng
    Li, Tiejun
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2024, 166 : 139 - 148
  • [5] CFD simulation of HC-290 leakage from a split type room air conditioner
    Ram Prakash, C.
    Gautham, M. R.
    Mohan Lal, D.
    Devotta, Sukumar
    Colbourne, D.
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2021, 235 (06) : 1847 - 1857
  • [6] Performance, environment, and cost-benefit analysis of a split air conditioning unit using HC-290 and HCFC-22
    Saravanan, A. Lalitha
    Prabakaran, Rajendran
    Sidney, Shaji
    Kim, Sung Chul
    Lal, Dhasan Mohan
    ENVIRONMENTAL PROGRESS & SUSTAINABLE ENERGY, 2022, 41 (01)
  • [7] Thermoeconomic analysis and optimization of residential split-type air conditioners
    Barreira, Eduardo M.
    Negrao, Cezar O. R.
    Hermes, Christian J. L.
    APPLIED THERMAL ENGINEERING, 2013, 50 (01) : 629 - 636
  • [8] Use of peripheral fins for R-290 charge reduction in split-type residential air-conditioners
    Ribeiro, Guilherme B.
    Barbosa Jr, Jader R.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2019, 106 : 1 - 6
  • [9] A mathematical model of critical releasable charge for R290 indoor leakage of split-type household air conditioners
    Ning, Qian
    He, Guogeng
    Xiong, Jun
    Fan, Mingjing
    Li, Xiao
    BUILDING AND ENVIRONMENT, 2023, 228
  • [10] Simulated and experimental performance of split packaged air conditioner using refrigerant HC-290 as a substitute for HCFC-22
    Padalkar, Atul S.
    Mali, Kundlik V.
    Devotta, Sukumar
    APPLIED THERMAL ENGINEERING, 2014, 62 (01) : 277 - 284