Stir bar sorptive extraction combined with high performance liquid chromatography-ultraviolet/inductively coupled plasma mass spectrometry for analysis of thyroxine in urine samples

被引:30
|
作者
Fan, Wenying [1 ]
Mao, Xiangju [1 ]
He, Man [1 ]
Chen, Beibei [1 ]
Hu, Bin [1 ]
机构
[1] Wuhan Univ, Dept Chem, Key Lab Analyt Chem Biol & Med, Minist Educ, Wuhan 430072, Peoples R China
关键词
Stir bar sorptive extraction; PEG/OH-PDMS/gamma-MPTS coating; HPLC-UV/ICP-MS; Amphoteric thyroxines analysis; Human urine; BIOLOGICAL SAMPLES; GAS-CHROMATOGRAPHY; IODINE SPECIATION; THYROID-HORMONES; HPLC; IODOTHYRONINES; ENANTIOMERS; WATER;
D O I
10.1016/j.chroma.2013.10.022
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In this work, polyethyleneglycol (PEG)/hydroxyl polydimethylsiloxane (OH-PDMS)/gamma-mercaptopropyl trimethoxysilane (gamma-MPTS) coated stir bar was prepared by sol-gel process and its extraction performance for the extraction of amphoteric thyroxines (3,3',5,5'-tetraiodothyronin, T-4; 3,3',5-triiodothyronine, T-3; reversed-3,3',5-triiodothyronine, rT(3)) and their metabolite (3,5-diiodothyronine, T-2) was studied. The preparation reproducibility of PEG/OH-PDMS/gamma-MPTS coated stir bar was investigated, and the relative standard deviations (RSDs) in the same batch and among different batches were 3.3-14.3% (n = 5) and 7.7-16.6% (n =3), respectively. The prepared PEG/OH-PDMS/gamma-MPTS coated stir bar could be reused for more than 20 times. Based on this fact, a novel method of stir bar sorptive extraction (SBSE) combined with high performance liquid chromatography (HPLC)-ultraviolet (UV) and HPLC-inductively coupled plasma mass spectrometry (ICP-MS) for the analysis of target thyroxines in human urine samples was developed. The influencing factors of SBSE, such as sample pH, extraction time, stirring rate, salt effect, desorption solution and desorption time, were studied in detail, and the analytical performance of the proposed method was evaluated under the optimized conditions. The enrichment factors (EFs) of the developed method for four target thyroxines were in the range of 14.9-70.4 (theoretical enrichment factor was 100). The RSDs were ranging from 4.0% to 13.8% for SBSE-HPLC-UV (c= 25 mu g/L, n = 6) and from 3.7% to 6.1% for SBSE-HPLC-ICP-MS (c = 0.5 mu g/L, n = 5). The linear range obtained by SBSE-HPLC-UV was 2-500 mu g/L for 12 and 5-500 mu g/L for rT(3), T-3 and T-4, with correlation coefficients (r) ranging from 0.9957 to 0.9998, respectively, while the linear range obtained by SBSE-HPLC-ICP-MS was 0.05-500 mu g/L for T-2 and rT(3), 0.10-200 mu g/L for T-3 and 0.05-200 mu g/L for 14 with r ranging from 0.9979 to 0.9998, respectively. The limits of detection (LODs) for the target thyroxines were 0.60-2.20 mu g/L for SBSE-HPLC-UV and 0.0071-0.0355 mu g/L SBSE-HPLC-ICP-MS, respectively. The developed method was applied for the determination of target thyroxines in urine samples, and the recovery for the spiking samples obtained by SBSE-HPLC-UV was in the range of 81.6-137.6% for human urine, while the recovery for the spiking urine samples obtained by SBSE-HPLC-ICP-MS were in the range of 72.0-121.5%. (C) 2013 Elsevier B.V. All rights reserved.
引用
收藏
页码:49 / 57
页数:9
相关论文
共 50 条
  • [2] Determination of Estrogens in Pork and Chicken Samples by Stir Bar Sorptive Extraction Combined with High-Performance Liquid Chromatography-Ultraviolet Detection
    Hu, Cong
    He, Man
    Chen, Beibei
    Hu, Bin
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (42) : 10494 - 10500
  • [3] Polydimethylsiloxane/covalent triazine frameworks coated stir bar sorptive extraction coupled with high performance liquid chromatography-ultraviolet detection for the determination of phenols in environmental water samples
    Zhong, Cheng
    He, Man
    Liao, Huaping
    Chen, Beibei
    Wang, Cheng
    Hu, Bin
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1441 : 8 - 15
  • [4] γ-mercaptopropyltrimethoxysilane Coated Stir Bar Sorptive Extraction Combined with Inductively Coupled Plasma Mass Spectrometry for the Determination of Copper, Cadmium, and Mercury in Environmental Water Samples
    Cui, Chao
    He, Man
    Chen, Beibei
    Hu, Bin
    ATOMIC SPECTROSCOPY, 2023, 44 (06) : 440 - 447
  • [5] Polydimethylsiloxane/metal-organic frameworks coated stir bar sorptive extraction coupled to high performance liquid chromatography-ultraviolet detector for the determination of estrogens in environmental water samples
    Hu, Cong
    He, Man
    Chen, Beibei
    Zhong, Cheng
    Hu, Bin
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1310 : 21 - 30
  • [6] Stir bar sorptive extraction coupled to liquid chromatography for the analysis of strobilurin fungicides in fruit samples
    Campillo, Natalia
    Vinas, Pilar
    Aguinaga, Nerea
    Ferez, Gema
    Hernandez-Cordoba, Manuel
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (27) : 4529 - 4534
  • [7] Polyaniline/cyclodextrin composite coated stir bar sorptive extraction combined with high performance liquid chromatography-ultraviolet detection for the analysis of trace polychlorinated biphenyls in environmental waters
    Lei, Yun
    He, Man
    Chen, Beibei
    Hu, Bin
    TALANTA, 2016, 150 : 310 - 318
  • [8] Water-compatible graphene oxide/molecularly imprinted polymer coated stir bar sorptive extraction of propranolol from urine samples followed by high performance liquid chromatography-ultraviolet detection
    Fan, Wenying
    He, Man
    You, Linna
    Zhu, Xuewei
    Chen, Beibei
    Hu, Bin
    JOURNAL OF CHROMATOGRAPHY A, 2016, 1443 : 1 - 9
  • [9] Molecularly imprinted stir bar sorptive extraction coupled with high performance liquid chromatography for trace analysis of sulfa drugs in complex samples
    Xu, Zhigang
    Song, Chaoyong
    Hu, Yuling
    Li, Gongke
    TALANTA, 2011, 85 (01) : 97 - 103
  • [10] Amino modified multi-walled carbon nanotubes/polydimethylsiloxane coated stir bar sorptive extraction coupled to high performance liquid chromatography-ultraviolet detection for the determination of phenols in environmental samples
    Hu, Cong
    Chen, Beibei
    He, Man
    Hu, Bin
    JOURNAL OF CHROMATOGRAPHY A, 2013, 1300 : 165 - 172