New methodology to obtain a calibration model for noninvasive near-infrared blood glucose monitoring

被引:70
|
作者
Maruo, K [1 ]
Oota, T
Tsurugi, M
Nakagawa, T
Arimoto, H
Tamura, M
Ozaki, Y
Yamada, Y
机构
[1] Matsushita Elect Works Ltd, Osaka 5618686, Japan
[2] Natl Inst Adv Ind Sci & Technol, Tsukuba, Ibaraki 3058564, Japan
[3] Hokkaido Univ, Res Inst Elect Sci, Sapporo, Hokkaido 0600812, Japan
[4] Kwansei Gakuin Univ, Sch Sci & Technol, Dept Chem, Sanda 6691337, Japan
[5] Kwansei Gakuin Univ, Sch Sci & Technol, Res Ctr Near Infrared Spect, Sanda 6691337, Japan
[6] Univ Electrocommun, Dept Mech Engn & Intelligent Syst, Chofu, Tokyo 1828585, Japan
关键词
near-infrared spectroscopy; NIR spectroscopy; diffuse reflectance; blood glucose monitoring; simulation of light propagation; noninvasive measurement; noninvasive analysis; chance temporal correlation;
D O I
10.1366/000370206776593780
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
This paper reports new methodology to obtain a calibration model for noninvasive blood glucose monitoring using diffuse reflectance near-infrared (NIR) spectroscopy. Conventional studies of noninvasive blood glucose monitoring with NIR spectroscopy use a calibration model developed by in vivo experimental data sets. In order to create a calibration model, we have used a numerical simulation of light propagation in skin tissue to obtain simulated NIR diffuse reflectance spectra. The numerical simulation method enables us to design parameters affecting the prediction of blood glucose levels and their variation ranges for a data set to create a calibration model using multivariate analysis without any in vivo experiments in advance. By designing the parameters and their variation ranges appropriately, we can prevent a calibration model from chance temporal correlations that are often observed in conventional studies using NIR spectroscopy. The calibration model (regression coefficient vector) obtained by the numerical simulation has a characteristic positive peak at the wavelength around 1600 nm. This characteristic feature of the regression coefficient vector is very similar to those obtained by our previous in vitro and in vivo experimental studies. This positive peak at around 1600 nm also corresponds to the characteristic absorption band of glucose. The present study has reinforced that the characteristic absorbance of glucose at around 1600 nm is useful to predict the blood glucose level by diffuse reflectance NIR spectroscopy. We have validated this new calibration methodology using in vivo experiments. As a result, we obtained a coefficient of determination, r(2), of 0.87 and a standard error of prediction (SEP) of 12.3 mg/dL between the predicted blood glucose levels and the reference blood glucose levels for all the experiments we have conducted. These results of ill vivo experiments indicate that if the parameters and their vibration ranges are appropriately taken into account in a numerical simulation, the new calibration methodology provides us with a very good calibration model that can predict blood glucose levels with small errors without conducting any experiments in advance to create a calibration model for each individual patient. This new calibration methodology using numerical simulation has promising potential for NIR spectroscopy, especially for noninvasive blood glucose monitoring.
引用
收藏
页码:441 / 449
页数:9
相关论文
共 50 条
  • [1] New advancement in noninvasive measurement of blood glucose by near-infrared spectroscopy
    Li, QB
    Wang, Y
    Xu, KX
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS: DIAGNOSTICS AND TREATMENT, 2002, 4916 : 457 - 464
  • [2] Noninvasive blood glucose monitoring by newly developed near-infrared spectroscopic system
    Maruo, K
    Tsurugi, M
    Tamura, M
    Ishii, M
    DIABETES, 2002, 51 : A124 - A124
  • [3] Noninvasive blood glucose monitoring using near-infrared dermis tissue spectra
    Maruo, K
    Tsurugi, M
    Chin, J
    Ota, T
    Arimoto, H
    Yamada, Y
    Tamura, M
    Ishii, M
    Ozaki, Y
    DIABETES, 2003, 52 : A435 - A435
  • [4] Noninvasive Blood Glucose Monitoring Systems Using Near-Infrared Technology-A Review
    Hina, Aminah
    Saadeh, Wala
    SENSORS, 2022, 22 (13)
  • [5] A nonlinear model for calibration of blood glucose noninvasive measurement using near infrared spectroscopy
    Li, Qing-Bo
    Li, Li-Na
    Zhang, Guang-Jun
    INFRARED PHYSICS & TECHNOLOGY, 2010, 53 (05) : 410 - 417
  • [6] On Feasibility of Near-Infrared Spectroscopy for Noninvasive Blood Glucose Measurements
    Vural, N. Mert
    Yoleri, Yigit
    Torun, Hamdi
    OPTICAL DIAGNOSTICS AND SENSING XIX: TOWARD POINT-OF-CARE DIAGNOSTICS, 2019, 10885
  • [7] A Noninvasive Blood Glucose Measurement System by Arduino and Near-infrared
    Zheng, Tuhong
    Li, Weixi
    Liu, Yuwei
    Ling, Bingo Wing-Kuen
    2016 IEEE INTERNATIONAL CONFERENCE ON CONSUMER ELECTRONICS-CHINA (ICCE-CHINA), 2016,
  • [8] Noninvasive near-infrared blood glucose monitoring using a calibration model built by a numerical simulation method: Trial application to patients in an intensive care unit
    Maruo, Katsuhiko
    Oota, Tomohiro
    Tsurugi, Mitsuhiro
    Nakagawa, Takehiro
    Arimoto, Hidenobu
    Hayakawa, Mineji
    Tamura, Mamoru
    Ozaki, Yukihiro
    Yamada, Yukio
    APPLIED SPECTROSCOPY, 2006, 60 (12) : 1423 - 1431
  • [9] Calibration model of individual optimization in blood glucose measurement using near-infrared spectroscopy
    Oishi, Keigo
    Ishizawa, Hiroaki
    Miyauchi, Yuki
    Fukuda, Masaya
    Journal of the Illuminating Engineering Institute of Japan (Shomei Gakkai Shi), 2014, 98 (02): : 62 - 67
  • [10] Calibration break-through for near-infrared, non-invasive blood glucose monitoring
    Garg, SK
    Fischer, JS
    Ruchti, TL
    Blank, TB
    Lorenz, AD
    Monfre, SL
    DIABETES, 2002, 51 : A122 - A122