Potentialities of mass spectrometry (ICP-MS) for actinides determination in urine

被引:28
|
作者
Bouvier-Capely, C
Ritt, J
Baglan, N
Cossonnet, C
机构
[1] IRSN, Ctr Fontenay Aux Roses, Dept Protect Sante Homme & Dosimetrie, F-92262 Fontenay Aux Roses, France
[2] CEA, Ctr Bruyeres Chatel, Dept Analyses & Surveillance Environm, F-91680 Bruyeres Le Chatel, France
关键词
actinides; urine; monitoring; ICP-MS; alpha spectrometry;
D O I
10.1016/j.apradiso.2004.01.007
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The applicability of inductively coupled plasma-mass spectrometry (ICP-MS) for determining actinides in urine was investigated. Performances of ICP-MS including detection limit and analysis time were studied and compared with a spectrometry performances. In the field of individual monitoring of workers, the comparison chart obtained in this study can be used as a guide for medical laboratories to select the most adequate procedure to be carried out depending on the case in question (the radioisotope to be measured, the required sensitivity, and the desired response time). (C) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:629 / 633
页数:5
相关论文
共 50 条
  • [1] Determination of total mercury in urine by inductively coupled plasma mass spectrometry (ICP-MS)
    Parsons, Patrick J.
    Palmer, Christopher D.
    Caldwel, Kathleen L.
    Jones, Robert L.
    PLASMA SOURCE MASS SPECTROMETRY: CURRENT TRENDS AND FUTURE DEVELOPMENTS, 2005, (301): : 59 - 71
  • [2] Neptunium determination by inductively coupled plasma mass spectrometry (ICP-MS)
    D. E. Vance
    V. F. Belt
    T. J. Oatts
    D. K. Mann
    Journal of Radioanalytical and Nuclear Chemistry, 1998, 234 : 143 - 147
  • [3] Determination of plutonium by inductively coupled plasma mass spectrometry (ICP-MS)
    Tonouchi, S
    Habuki, H
    Katoh, K
    Yamazaki, K
    Hashimoto, T
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2002, 252 (02) : 367 - 371
  • [4] Validation of uranium determination in urine by ICP-MS
    Bouvier-Capely, C
    Baglan, N
    Montègue, A
    Ritt, J
    Cossonnet, C
    HEALTH PHYSICS, 2003, 85 (02): : 216 - 219
  • [5] Determination of plutonium by inductively coupled plasma mass spectrometry (ICP-MS)
    S. Tonouchi
    H. Habuki
    K. Katoh
    K. Yamazaki
    T. Hashimoto
    Journal of Radioanalytical and Nuclear Chemistry, 2002, 252 : 367 - 371
  • [6] Neptunium determination by inductively coupled plasma mass spectrometry (ICP-MS)
    Vance, DE
    Belt, VF
    Oatts, TJ
    Mann, DK
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1998, 234 (1-2) : 143 - 146
  • [7] Reference ranges for urine elements by inductively coupled plasma - Mass spectrometry (ICP-MS).
    Pielack, G
    Freer, DE
    Lee, MJ
    CLINICAL CHEMISTRY, 1997, 43 : 792 - 792
  • [8] Procedure for direct determination of uranium in urine by ICP-MS
    Ritt, J.
    Cossonnet, C.
    Radioprotection, 2001, 36 (02) : 167 - 181
  • [9] Method for the determination of thorium and uranium in urine by ICP-MS
    P. Schramel
    I. Wendler
    P. Roth
    E. Werner
    Microchimica Acta, 1997, 126 : 263 - 266
  • [10] Method for the Determination of Thorium and Uranium in Urine by ICP-MS
    Schramel, P.
    Wendler, I.
    Roth, P.
    Werner, E.
    Mikrochimica Acta, 126 (3-4):