Experimental study on gas liquid flow distributions in upward multi-pass channels-Comparison of R-134a flow and air water flow

被引:4
|
作者
Razlan, Z. M. [1 ]
Bakar, S. A. [1 ]
Desa, H. [1 ]
Wan, W. K. [1 ]
Zunaidi, I. [5 ]
Ibrahim, I. [1 ]
Kamarrudin, N. S. [1 ]
Ridzuan, M. J. M. [1 ]
Takiguchi, K. [3 ]
Tsuchiya, T. [4 ]
Kitade, Y.
Hirota, M. [2 ]
Maruyama, N. [2 ]
Nishimura, A. [2 ]
机构
[1] Univ Malaysia Perlis, Sch Mechatron Engn, Pauh Petra Campus, Arau 02600, Perlis, Malaysia
[2] Mie Univ, Dept Mech Engn, Tsu, Mie, Japan
[3] Fuji Elect Co Ltd, Yokaichi, Mie, Japan
[4] Fuji Elect Co Ltd, Shinagawa, Tokyo, Japan
[5] Technopreneur UniMAP Sdn Bhd, Kangar, Perlis, Malaysia
关键词
Multi-pass channel; Flow distribution; Flow visualization; R-134a; Air-water flow; HEAT-TRANSFER CHARACTERISTICS; REFRIGERANT DISTRIBUTION; HORIZONTAL HEADERS; PARALLEL CHANNELS; PRESSURE-DROP; ANNULAR-FLOW; 2-PHASE; PATTERNS;
D O I
10.1016/j.expthermflusci.2017.10.004
中图分类号
O414.1 [热力学];
学科分类号
摘要
An experimental study was conducted on the gas liquid two-phase flow distributions in a multi-pass channel that simulated a compact evaporator in a heat-pump system, with a focus on the similarity between the refrigerant (R-134a) flow and the air water flow. The body of the test channel was made of transparent polyvinyl chloride to allow optical access, and multiport aluminum tubes were used as branches. Horizontal dividing and combining headers with cross sections of 20 mm x 20 mm were connected by 22 upward branches with cross sections of 20 mm x 2 mm, lengths of 120 mm, and pitches of 12 mm. Initially, the refrigerant two-phase flow was visualized to clarify the characteristics of the flow in the headers. Then, using the same test channel, the air water flow in the headers was observed under four air and water velocity conditions at the dividing header entrance to investigate the similarity with the flow pattern of the refrigerant flow: (i) superficial gas and liquid velocities equal to those of the refrigerant flow, (ii) equal kinetic energies, (iii) equal quality and mass flow rate, (iv) equal Baker's flow pattern map parameters. A comparison of the flow patterns in the dividing header revealed that the air water flow under the inlet conditions of the equal kinetic energies and equal Baker's flow pattern map parameters simulated the refrigerant flow closely. Then, based on this result, the air and water distribution ratios in the branches were measured under these two conditions to examine the influence of the flow inlet conditions on the flow-distribution characteristics. A close comparison of the air water distributions and the refrigerant flow in the combining header revealed that the inlet condition of equal Baker's flow pattern map parameters yielded better results than the equal-kinetic energy condition.
引用
收藏
页码:134 / 143
页数:10
相关论文
共 50 条
  • [1] Parameters of Gas-Liquid Flow Distribution Uniformity in Upward Multi-Pass Channels
    Razlan, Zuradzman M.
    Hazry, D.
    Heng, R.
    Shahriman, A. B.
    Wan, Khairunizam
    Ahmed, S. Faiz
    Adnan, Nazrul H.
    Hirota, M.
    Maruyama, N.
    Nishimura, A.
    Hisyam, H.
    PROCEEDINGS OF INTERNATIONAL CONFERENCE ON ARTIFICIAL LIFE AND ROBOTICS (ICAROB 2014), 2014, : 284 - 287
  • [2] GAS-LIQUID DISTRIBUTIONS IN UPWARD MULTI-PASS CHANNELS OF COMPACT EVAPORATOR
    Razlan, Zuradzman Mohamad
    Isobe, Ryota
    Mizuno, Yasuhiro
    Goshima, Hiroaki
    Hirota, Masafumi
    Maruyama, Naoki
    Nishimura, Akira
    PROCEEDINGS OF THE ASME INTERNATIONAL HEAT TRANSFER CONFERENCE - 2010 , VOL 3: COMBUSTION, CONDUCTION, ELECTRONIC COOLING, EVAPORATION,TWO-PHASE FLOW, 2010, : 913 - 921
  • [3] GAS-LIQUID FLOW DISTRIBUTION UNIFORMITY PARAMETERS IN UPWARD MULTI-PASS COMPACT EVAPORATOR
    Razlan, Zuradzman Mohamad
    Desa, Hazry
    Abu Bakar, Shahriman
    Wan, Khairunizam
    Ibrahim, Ishak
    Heng, R.
    Hussain, Abadalsalam T.
    Hirota, Masafumi
    Maruyama, Naoki
    Nishimura, Akira
    Hamdan, Hisyam
    JURNAL TEKNOLOGI, 2016, 78 (10-3): : 7 - 11
  • [4] Experimental study of post-dryout with R-134a upward flow in smooth tube and rifled tubes
    Lee, Song Kyu
    Chang, Soon Heung
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2008, 51 (11-12) : 3153 - 3163
  • [5] Effect of Serpentine Multi-pass Flow Field Channel Orientation in the Liquid Water Distributions and Cell Performance
    Iranzo, A.
    Biesdorf, J.
    Cochet, M.
    Salva, A.
    Boillat, P.
    Rosa, F.
    FUEL CELLS, 2016, 16 (06) : 777 - 783
  • [6] Experimental study of the flow of R-134a through an adiabatic helically coiled capillary tube
    Khan, Mohd Kaleem
    Kumar, Ravi
    Sahoo, Pradeep K.
    HVAC&R RESEARCH, 2008, 14 (05): : 749 - 762
  • [7] An experimental study of the flow of R-134a inside an adiabatic spirally coiled capillary tube
    Khan, Mohd. Kaleem
    Kumar, Ravi
    Sahoo, Pradeep K.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2008, 31 (06): : 970 - 978
  • [8] An experimental investigation of flow boiling heat transfer of R-134a in horizontal and vertical mini-channels
    Saisorn, Sira
    Kaew-On, Jatuporn
    Wongwises, Somchai
    EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2013, 46 : 232 - 244
  • [9] Experimental study of the gravity effect on the distribution of refrigerant flow in a multi-pass condenser
    Lee, J
    Kim, MH
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (08): : 993 - 1002
  • [10] Flow pattern of air-water and two-phase R-134a in small circular tubes
    Yang, CY
    Shieh, CC
    INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2001, 27 (07) : 1163 - 1177