Hardware-related problems of deep brain stimulation

被引:107
|
作者
Joint, C
Nandi, D
Parkin, S
Gregory, R
Aziz, T
机构
[1] Radcliffe Infirm, Dept Neurosurg, Oxford OX2 6HE, England
[2] Univ Oxford, Physiol Lab, Oxford OX1 3PT, England
[3] Radcliffe Infirm, Dept Neurol, Oxford OX2 6HE, England
关键词
Deep brain stimulation; Hardware failure; Prospective study;
D O I
10.1002/mds.10161
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Deep brain stimulation for the alleviation of movement disorders and pain is now an established therapy. However, very little has been published on the topic of hardware failure in the treatment of such conditions irrespective of clinical outcome. Such device-related problems lead to significant patient morbidity and increased cost of therapy in the form of prolonged antibiotics, in-patient hospitalization, repeat surgery, and device replacement. We report a prospective review of our experience at the Radcliffe Infirmary Oxford from the period of April 1998 to March 2001. Overall there is a 20% rate of hardware-related problems in this series, which falls between the 7% and 65% rates reported by other groups. The majority of these failures occurred early on in the series, and numbers declined with experience. Some of the problems may be idiosyncratic to the methodology of individual groups. (C) 2002 Movement Disorder Society.
引用
收藏
页码:S175 / S180
页数:6
相关论文
共 50 条
  • [1] Reducing hardware-related complications of deep brain stimulation
    Constantoyannis, C
    Berk, C
    Honey, CR
    Mendez, I
    Brownstone, RM
    CANADIAN JOURNAL OF NEUROLOGICAL SCIENCES, 2005, 32 (02) : 194 - 200
  • [2] Anosognosia for Hardware-Related Complications in Deep Brain Stimulation
    Fernandes, F. Wolff
    Runge, J.
    Saryyeva, A.
    Krauss, J. K.
    MOVEMENT DISORDERS, 2024, 39 : S881 - S881
  • [3] Hardware-related complications of deep brain stimulation: A review of 221 cases
    Li, J.
    Zhang, Y.
    Li, Y.
    MOVEMENT DISORDERS, 2009, 24 : S467 - S468
  • [4] Hardware-related complications of deep brain stimulation: a ten year experience
    P. Blomstedt
    M. I. Hariz
    Acta Neurochirurgica, 2005, 147 : 1061 - 1064
  • [5] Hardware-related complications of deep brain stimulation: A review of the published literature
    Hamani, Clement
    Lozano, Andres M.
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2006, 84 (5-6) : 248 - 251
  • [6] Long-term hardware-related complications of deep brain stimulation
    Oh, MY
    Abosch, A
    Kim, SH
    Lang, AE
    Lozano, AM
    NEUROSURGERY, 2002, 50 (06) : 1268 - 1274
  • [7] Hardware-related complications of deep brain stimulation: a ten year experience
    Blomstedt, P
    Hariz, MI
    ACTA NEUROCHIRURGICA, 2005, 147 (10) : 1061 - 1064
  • [8] Avoidance and Management of Surgical and Hardware-Related Complications of Deep Brain Stimulation
    Hu, Xiaowu
    Jiang, Xiufeng
    Zhou, Xiaoping
    Liang, Jinchuan
    Wang, Laixing
    Cao, Yiqun
    Liu, Jianmin
    Jin, Aiguo
    Yang, Pengfei
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2010, 88 (05) : 296 - 303
  • [9] Long-Term Surgical and Hardware-Related Complications of Deep Brain Stimulation
    Doshi, Paresh K.
    STEREOTACTIC AND FUNCTIONAL NEUROSURGERY, 2011, 89 (02) : 89 - 95