Energy saving effect of hotel central air conditioning systems with energy efficiency management system

被引:0
|
作者
Wang, Delin [1 ]
Chen, Wei
Li, Yi [1 ]
Chen, Juxin [1 ]
Han, Jibing
Zhai, Miao
机构
[1] Shandong Jianzhu Univ, Sch Thermal & Engine Engn, Jinan, Peoples R China
关键词
air-conditioning condition; average power saving rate; dynamic adjustment; energy efficiency management;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
An architecture energy efficiency tracking, control and management system was proposed for energy conservation of the central air conditioning system of a star hotel. And its energy-saving effect was detected with three departments participated in, Shandong Institute of Metrology, Shandong Energy Test Centre, and Shandong Institute of Supervision & Inspection on Product Quality, to assure the authenticity and reliability. With the system, the power saving rate decreased in July and August because of steady load and efficient equipment, which shows that energy efficiency management system changes with the outside temperature and energy saving control system can track changes with load automatically and adjust dynamically. Real-time detection shows average power saving rate is 41.05% in summer (May, June, July and August are summer condition) and 46.8% in winter (December and January are winter condition). The following aspects are discussed, first, the unreasonable original design of equipment matching, second, the improvement of equipment efficiency under part-load condition, third, the energy saving potential of dynamic management and operation system, and last, the necessity of energy efficiency management system to be modularized, refined and intelligentized.
引用
收藏
页码:2201 / 2206
页数:6
相关论文
共 50 条
  • [1] The Energy Consumption Investigation of the Hotel Central Air-conditioning System and the Research of Energy Saving Measures
    Ni, Jiajia
    Tao, Li
    Wang, Yijun
    Wu, Jinlei
    ADVANCES IN MANUFACTURING SCIENCE AND ENGINEERING, PTS 1-4, 2013, 712-715 : 1614 - 1618
  • [2] SIMULATION OF ENERGY SAVING CONTROL FOR A CENTRAL AIR CONDITIONING SYSTEM
    Bing, Wei
    Na, Pei
    Jing, Liu
    Juan, Tang
    PROCEEDINGS OF THE ASME 5TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY 2011, PTS A-C, 2012, : 983 - 990
  • [3] Analysis of Energy-Saving Measures on the Operation and Management of Central Air Conditioning System
    Gao, Sudi
    Pan, Zhengwei
    CONSTRUCTION AND URBAN PLANNING, PTS 1-4, 2013, 671-674 : 2511 - 2514
  • [4] Energy Saving Solution for Air Conditioning Systems
    Vu Thu Diep
    Phan Duy Hung
    Tung, Ta Duc
    FUTURE DATA AND SECURITY ENGINEERING (FDSE 2019), 2019, 11814 : 618 - 628
  • [5] AIR-CONDITIONING SYSTEMS FOR ENERGY SAVING
    TOCHIMOTO, K
    MIYAZAKI, K
    TAKAKUSAGI, A
    JAPAN TELECOMMUNICATIONS REVIEW, 1979, 21 (04): : 391 - 401
  • [6] Research on Energy-saving Control Technology and Energy-saving Effect Verification of Central Air Conditioning System in Subway Station
    Wu, Jiang
    Qian, Cheng
    Luo, Dingxin
    Lin, Zhiyuan
    Cai, Wenling
    Qian, Yu
    Yang, Chun
    2024 3RD INTERNATIONAL CONFERENCE ON ENERGY AND ELECTRICAL POWER SYSTEMS, ICEEPS 2024, 2024, : 76 - 82
  • [7] Analysis of energy saving technology for Central Air Conditioning water system operation
    Liu, Jingfeng
    Wang, Jun
    Li, Guangpeng
    INTERNATIONAL CONFERENCE ON MECHANICAL DESIGN AND SIMULATION (MDS 2022), 2022, 12261
  • [8] Fuzzy logic based energy saving technique for a central air conditioning system
    Ahmed, S. Shahnawaz
    Majid, Md. Shah
    Novia, Hendri
    Rahman, Hasimah Abd
    ENERGY, 2007, 32 (07) : 1222 - 1234
  • [9] An Energy Saving Model Predictive Control for Central Air-Conditioning System
    Wu, Zhangxian
    Yang, Guotian
    Liu, Xiangjie
    Sheng, Xing
    Song, Pengchuan
    TENCON 2009 - 2009 IEEE REGION 10 CONFERENCE, VOLS 1-4, 2009, : 356 - +
  • [10] Research on energy saving control of chilled water system of central air conditioning system
    Ju, Li Zhuang
    Cai, Lv
    Jie, Mei
    PROCEEDINGS OF THE 28TH CHINESE CONTROL AND DECISION CONFERENCE (2016 CCDC), 2016, : 2875 - 2878