24-Hour variation of optical coherence tomography-measured retinal thickness in diabetic macular edema

被引:13
|
作者
Kotsidis, Sokratis T. [1 ]
Lake, Simeon S. [1 ]
Alexandridis, Alexandros D. [1 ]
Ziakas, Nikolaos G. [1 ]
Ekonomidis, Panagiotis K. [1 ]
机构
[1] AHEPA Univ Hosp, Dept Ophthalmol 1, Thessaloniki, Greece
关键词
Diabetic macular edema; Diurnal variation; Optical coherence tomography; Retinal thickness; DIURNAL-VARIATION; REPRODUCIBILITY; PREVALENCE;
D O I
10.5301/ejo.5000119
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE. To investigate 24-hour variation in retinal thickness in patients with diabetic macular edema (DME) using optical coherence tomography (007). METHODS. Fifty-three eyes of 53 diabetic patients with clinically significant macular edema and central sub field thickness (CST) >225 mu m, 36 eyes of 36 healthy individuals (normal controls), and 22 eyes of 22 diabetic patients without macular pathology (diabetic controls) underwent 5 OCT measurements at 7 Am, 10 AM, 3 PM, 8 pm, and 1 AM. Visual acuity, blood pressure, blood glucose, and body temperature were measured as well. RESULTS. The CST (p<0.0005), total macular volume (p<0.0005), and visual acuity (p<0.0005) showed significant variation in patients. The CST (450 pm at 7 Am) reached a minimum at 3 PM (absolute change of -49 mu m, relative change of -17%) before increasing again. Thickening changes were higher in more thickened retinas (p<0.0005, p=0.024, absolute and relative change, respectively). Visual acuity was worse in the morning (0.38 logMAR) and improved to a maximum at 8 PM (0.30 logMAR) (p<0.0005). Blood pressure, blood glucose, and body temperature did not vary over time. CONCLUSIONS. The 24-hour variation of retinal thickness is observed in a large proportion of patients with DME, with a decrease from morning to afternoon. Time of examination should be taken into account when managing such patients.
引用
收藏
页码:785 / 791
页数:7
相关论文
共 50 条
  • [1] The variation in optical coherence tomography-measured macular thickness in diabetic eyes without clinical macular edema
    Browning, David J.
    Fraser, Christina M.
    Propst, Bradley W.
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 145 (05) : 889 - 893
  • [2] Relationship between optical coherence tomography-measured central retinal thickness and visual acuity in diabetic macular edema
    Browning, David J.
    Glassman, Adam R.
    Aiello, Lloyd Paul
    Beck, Roy W.
    Brown, David M.
    Fong, Donald S.
    Bressler, Neil M.
    Danis, Ronald P.
    Kinyoun, James L.
    Nguyen, Quan Dong
    Bhavsar, Abdhish R.
    Gottlieb, Justin
    Pieramici, Dante J.
    Rauser, Michael E.
    Apte, Rajendra S.
    Lim, Jennifer I.
    Miskala, Pdivi H.
    Solomon, Sharon D.
    Bressler, Susan
    Finkelstein, Daniel
    Gehlbach, Peter L.
    Nguyen, Quan Dong
    Sung, Jennifer U.
    Zimmer-Galler, Ingrid
    Doll, Warren
    Donohue, Deborah
    Jurao, Robert
    Sheehan, Siobhan E.
    Belt, Judith
    Sharuk, George S.
    Arrigg, Paul G.
    Schlossman, Deborah K.
    Shah, Sabera T.
    Kopple, Ann
    Stockman, Margaret E.
    Bestourous, Leila
    Calderon, Richard M.
    Cavallerano, Jerry D.
    Chau, Tak
    Cavicchi, Robert W.
    Strong, James
    Wells, John A.
    Clark, Lloyd
    Bearden, Ruth T.
    Taylor, Mallie M.
    Spivey, Robbin
    Evans, Mark A.
    Stone, Marsha L.
    Gardner, Thomas W.
    Neely, Kimberly A.
    OPHTHALMOLOGY, 2007, 114 (03) : 525 - 536
  • [3] Temporal variation in diabetic macular edema measured by optical coherence tomography
    Frank, RN
    Schulz, L
    Abe, K
    Iezzi, R
    OPHTHALMOLOGY, 2004, 111 (02) : 211 - 217
  • [4] Intravitreal triamcinolone acetonide: Valuation of retinal thickness changes measured by optical coherence tomography in diffuse diabetic macular edema
    Ferrari, TM
    Sborgia, L
    Furino, C
    Cardascia, N
    Ferreri, P
    Besozzi, G
    Sborgia, C
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2004, 14 (04) : 321 - 324
  • [5] RETINAL THICKNESS AND VOLUME MEASUREMENTS IN DIABETIC MACULAR EDEMA A Comparison of Four Optical Coherence Tomography Systems
    Lammer, Jan
    Scholda, Christoph
    Pruente, Christian
    Benesch, Thomas
    Schmidt-Erfurth, Ursula
    Bolz, Matthias
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2011, 31 (01): : 48 - 55
  • [6] Optical coherence tomography for retinal thickness measurement in diabetic patients without clinically significant macular edema
    Schaudig, UH
    Glaefke, C
    Scholz, F
    Richard, G
    OPHTHALMIC SURGERY AND LASERS, 2000, 31 (03): : 182 - 186
  • [7] Retinal Thickness and Visual Acuity in Diabetic Macular Edema: An Optical Coherence Tomography-Based Study
    Islam, Farrah
    Ashraf, Muhammad
    Zafar, Saemah
    Masood, Haleema
    Qureshi, Nadeem
    JCPSP-JOURNAL OF THE COLLEGE OF PHYSICIANS AND SURGEONS PAKISTAN, 2016, 26 (07): : 598 - 601
  • [8] Retinal thickness measurement and evaluation of natural history of the diabetic macular edema through optical coherence tomography
    Hannouche, Rosana Zacarias
    de Avila, Marcos Pereira
    ARQUIVOS BRASILEIROS DE OFTALMOLOGIA, 2009, 72 (04) : 433 - 438
  • [9] Macular thickness measured by optical coherence tomography (OCT) in diabetic patients
    Lattanzio, R
    Brancato, R
    Pierro, L
    Bandello, F
    Iaccheri, B
    Fiore, T
    Maestranzi, G
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2002, 12 (06) : 482 - 487
  • [10] Comparing central retinal thickness in diabetic macular edema measured by two different spectral-domain optical coherence tomography devices
    Kiyoshi Suzuma
    Yoshihisa Yamada
    Michi Liu
    Eiko Tsuiki
    Azusa Fujikawa
    Takashi Kitaoka
    Japanese Journal of Ophthalmology, 2011, 55 : 620 - 624