Device for Calibration of Piezoelectric Sensors

被引:7
|
作者
Gaponenko, S. O. [1 ]
Kondratiev, A. E. [1 ]
机构
[1] Kazan State Power Engn Univ, 51 Krasnoselskaya Str, Kazan 420066, Russia
关键词
vibroacoustic signal; the resonant frequency; useful signal spectrum; vibrating stand; a piezoelectric sensor; a vibration amplitude;
D O I
10.1016/j.proeng.2017.10.451
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Any experimental studies related to vibration measurement cannot be conducted without calibration of sensors. The purpose of the calibration is to determine sensitivity of the sensors in the operating range of frequencies and amplitudes. To this end, we developed a method and installation is made with a unified software package in the LabVIEW programming environment. The results obtained by the piezoelectric sensor calibration setting showed the ability to calibrate any piezoelectric transducers in the frequency range above 100 Hz. When calibrating the sensor at a frequency less than 100 Hz, it is necessary to take into account the distortions associated with their own oscillation modes at the vibrating stand. (C) 2017 The Authors. Published by Elsevier Ltd.
引用
收藏
页码:146 / 150
页数:5
相关论文
共 50 条
  • [1] Comparison of Calibration Techniques for Piezoelectric Force Sensors
    Mains, Michael
    Peres, Marco
    Kallmeyer, Chad
    Dillon, Mike
    Weaver, Cole
    Bono, Rick
    SENSORS & INSTRUMENTATION AND AIRCRAFT/AEROSPACE TESTING TECHNIQUES, VOL. 8, IMAC 2024, 2025, : 47 - 57
  • [2] On calibration of piezoelectric sensors with laser doppler vibrometer
    Ghaffari, H. O.
    Mok, U.
    Pec, Matej
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2021, 150 (04): : 2503 - 2513
  • [3] Discussion on the absolute calibration of piezoelectric acoustic emission sensors
    He Longbiao
    Wang Yuying
    Zhu Haijiang
    Yang Ping
    SEVENTH INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENTS, 2016, 9903
  • [4] Preparation of urea sensors with a series piezoelectric crystal device
    Xu, YJ
    Lu, CY
    Hu, Y
    Nie, LH
    Yao, SZ
    ANALYTICAL LETTERS, 1996, 29 (07) : 1069 - 1080
  • [5] Calibration of piezoelectric bedload impact sensors in the Pitzbach mountain stream
    Rickenmann, D.
    McArdell, B. W.
    GEODINAMICA ACTA, 2008, 21 (1-2) : 35 - 51
  • [6] CONSISTENCY OF SURFACE PULSE AND RECIPROCITY CALIBRATION OF PIEZOELECTRIC AE SENSORS
    Wang, Yu-ying
    He, Long-biao
    Zhu, Hai-jiang
    Yang, Ping
    PROCEEDINGS OF THE 2015 SYMPOSIUM ON PIEZOELECTRICITY, ACOUSTIC WAVES AND DEVICE APPLICATIONS, 2015, : 189 - 192
  • [7] Development of a Vibration Energy Harvesting Device Using Piezoelectric Sensors
    Jayarathne, W. M.
    Nimansala, W. A. T.
    Adikary, S. U.
    2018 MORATUWA ENGINEERING RESEARCH CONFERENCE (MERCON) 4TH INTERNATIONAL MULTIDISCIPLINARY ENGINEERING RESEARCH CONFERENCE, 2018, : 197 - 202
  • [8] Piezoelectric AlN films for FPW sensors with improved device performance
    Reusch, Markus
    Hole, Katarzyna
    Kirste, Lutz
    Katus, Philip
    Reindl, Leonhard
    Ambacher, Oliver
    Lebedev, Vadim
    PROCEEDINGS OF THE 30TH ANNIVERSARY EUROSENSORS CONFERENCE - EUROSENSORS 2016, 2016, 168 : 1040 - 1043
  • [9] Piezoelectric AlN films for FPW sensors with improved device performance
    Reusch, Markus
    Holc, Katarzyna
    Kirste, Lutz
    Katus, Philip
    Reindl, Leonhard
    Ambacher, Oliver
    Lebedev, Vadim
    PROCEEDINGS OF THE 30TH ANNIVERSARY EUROSENSORS CONFERENCE - EUROSENSORS 2016, 2016, 168 : 537 - 540
  • [10] Accuracy specifications of calibration device for Force-Torque Sensors
    Zarutckii, Nikolai
    Bulkin, Roman
    2016 IEEE INTERNATIONAL CONFERENCE ON MULTISENSOR FUSION AND INTEGRATION FOR INTELLIGENT SYSTEMS (MFI), 2016, : 78 - 83