Design and performance of the ULTRA 320x240 uncooled focal plane array and sensor

被引:26
|
作者
Herring, RJ [1 ]
Howard, PE [1 ]
机构
[1] INFRAMETR INC, N BILLERICA, MA 01862 USA
来源
INFRARED DETECTORS AND FOCAL PLANE ARRAYS IV | 1996年 / 2746卷
关键词
D O I
10.1117/12.243040
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
引用
收藏
页码:2 / 12
页数:11
相关论文
共 50 条
  • [1] 320x240 microbolometer focal plane array for uncooled applications
    Radford, W
    Murphy, D
    Ray, M
    Propst, S
    Kennedy, A
    Soch, K
    Coda, R
    Lung, G
    Moody, E
    Gleichman, D
    PHOTODETECTORS: MATERIALS AND DEVICES, 1996, 2685 : 80 - 90
  • [2] Performance of 320x240 uncooled bolometer-type infrared focal plane arrays
    Tanaka, Y
    Tanaka, A
    Iida, K
    Sasaki, T
    Tohyama, S
    Akira, AB
    Kawahara, A
    Kurasina, S
    Endoh, T
    Kawano, K
    Okuyama, K
    Egashira, K
    Aoki, H
    Oda, N
    INFRARED TECHNOLOLGY AND APPLICATIONS XXIX, 2003, 5074 : 414 - 424
  • [3] Advanced high-performance 320x240 VOX microbolometer uncooled IR focal plane
    Howard, PE
    Clarke, JE
    Parrish, WJ
    Woolaway, JT
    INFRARED TECHNOLOGY AND APPLICATIONS XXV, 1999, 3698 : 131 - 136
  • [4] Hyperspectral study of a 320x240 uncooled microbolometer array
    Guérineau, N
    Harchaoui, B
    Caes, M
    Durand, A
    Castelein, P
    OPTICAL DESIGN AND ENGINEERING, 2004, 5249 : 433 - 440
  • [5] 320x240 microbolometer uncooled IRFPA
    Mottin, E
    Martin, JL
    Ouvrier-Buffet, JL
    Vilain, M
    Yon, JJ
    Chatard, JP
    INFRARED DETECTORS AND FOCAL PLANE ARRAYS VI, 2000, 4028 : 39 - 46
  • [6] Infrared camera based on 320 X 240 uncooled focal plane array
    Li, YW
    Yi, XJ
    He, ZX
    Luo, Y
    MULTISPECTRAL AND HYPERSPECTRAL IMAGE ACQUISITION AND PROCESSING, 2001, 4548 : 297 - 301
  • [7] The miniaturized design for drive circuits of 320*240 uncooled infrared focal plane array
    Xing, SX
    Huang, CY
    Chang, BK
    Qian, YS
    Zhang, JJ
    SIGNAL AND DATA PROCESSING OF SMALL TARGETS 2003, 2003, 5204 : 524 - 531
  • [8] 320x240 microbolometer uncooled IRFPA development
    Tissot, JL
    Martin, JL
    Mottin, E
    Vilain, M
    Yon, JJ
    Chatard, JP
    INFRARED TECHNOLOGY AND APPLICATIONS XXVI, 2000, 4130 : 473 - 479
  • [9] High-background, longwave Si:As IBC 320x240 IR focal plane array
    Solomon, S
    Tribble, A
    Lum, N
    Venzon, J
    Domingo, G
    Hoffman, A
    Smith, M
    INFRARED DETECTORS FOR REMOTE SENSING: PHYSICS, MATERIALS, AND DEVICES, 1996, 2816 : 161 - 168
  • [10] Microspectrometer on a chip (MICROSPOC):: first demonstration on a 320x240 LWIR HgCdTe focal plane array.
    Rommeluere, S
    Guérineau, N
    Deschamps, J
    De Borniol, E
    Million, A
    Chamonal, JP
    Destefanis, G
    INFRARED TECHNOLOGY AND APPLICATIONS XXX, 2004, 5406 : 170 - 177