Influence of Thin Slice Reconstruction on CT Brain Perfusion Analysis

被引:11
|
作者
Bennink, Edwin [1 ,2 ]
Oosterbroek, Jaap [1 ,2 ]
Horsch, Alexander D. [1 ]
Dankbaar, Jan Willem [1 ]
Velthuis, Birgitta K. [1 ]
Viergever, Max A. [2 ]
de Jong, Hugo W. A. M. [1 ,2 ]
机构
[1] Univ Med Ctr Utrecht, Dept Radiol, Utrecht, Netherlands
[2] Univ Med Ctr Utrecht, Image Sci Inst, Utrecht, Netherlands
来源
PLOS ONE | 2015年 / 10卷 / 09期
关键词
ACUTE ISCHEMIC-STROKE; CEREBRAL-BLOOD-FLOW; COMPUTED-TOMOGRAPHY; THRESHOLDS VARY; VENOUS OUTPUT; INFARCT CORE; PENUMBRA; VOLUME; MAPS; PERMEABILITY;
D O I
10.1371/journal.pone.0137766
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Objectives Although CT scanners generally allow dynamic acquisition of thin slices (1 mm), thick slice (>= 5 mm) reconstruction is commonly used for stroke imaging to reduce data, processing time, and noise level. Thin slice CT perfusion (CTP) reconstruction may suffer less from partial volume effects, and thus yield more accurate quantitative results with increased resolution. Before thin slice protocols are to be introduced clinically, it needs to be ensured that this does not affect overall CTP constancy. We studied the influence of thin slice reconstruction on average perfusion values by comparing it with standard thick slice reconstruction. Materials and Methods From 50 patient studies, absolute and relative hemisphere averaged estimates of cerebral blood volume (CBV), cerebral blood flow (CBF), mean transit time (MTT), and permeability-surface area product (PS) were analyzed using 0.8, 2.4, 4.8, and 9.6 mm slice reconstructions. Specifically, the influence of Gaussian and bilateral filtering, the arterial input function (AIF), and motion correction on the perfusion values was investigated. Results Bilateral filtering gave noise levels comparable to isotropic Gaussian filtering, with less partial volume effects. Absolute CBF, CBV and PS were 22%, 14% and 46% lower with 0.8 mm than with 4.8 mm slices. If the AIF and motion correction were based on thin slices prior to reconstruction of thicker slices, these differences reduced to 3%, 4% and 3%. The effect of slice thickness on relative values was very small. Conclusions This study shows that thin slice reconstruction for CTP with unaltered acquisition protocol gives relative perfusion values without clinically relevant bias. It does however affect absolute perfusion values, of which CBF and CBV are most sensitive. Partial volume effects in large arteries and veins lead to overestimation of these values. The effects of reconstruction slice thickness should be taken into account when absolute perfusion values are used for clinical decision making.
引用
收藏
页数:14
相关论文
共 50 条
  • [1] Multi-slice CT brain image registration for perfusion studies
    Lin, ZMS
    Pohlman, S
    Chandra, S
    MEDICAL IMAGING 2002: PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES, 2002, 4683 : 484 - 491
  • [2] Reduction in radiation dose with reconstruction technique in the brain perfusion CT
    Kim, H. J.
    Lee, H. K.
    Song, H.
    Ju, M. S.
    Dong, K. R.
    Chung, W. K.
    Cho, M. S.
    Cho, J. H.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2011, 166 (12): : 918 - 926
  • [3] Patient dose in brain perfusion imaging using an 80-slice CT system
    Messaris, Gerasimos A. T.
    Georgakopoulos, Dimitrios N.
    Zampakis, Petros
    Kalogeropoulou, Christina P.
    Petsas, Theodoros G.
    Panayiotakis, George S.
    JOURNAL OF NEURORADIOLOGY, 2019, 46 (04) : 243 - 247
  • [4] Improved signal-to-noise ratio in thick versus thin slice CT perfusion maps
    Hamedanchi, R
    Camargo, EC
    Gulick, SM
    Furie, KL
    Koroshetz, WJ
    Lev, MH
    STROKE, 2006, 37 (02) : 653 - 653
  • [5] Noise filtering in thin-slice 4D Cerebral CT Perfusion scans
    Mendrik, Adrienne
    Vonken, Evert-jan
    Dankbaar, Jan-Willem
    Prokop, Mathias
    van Ginneken, Bram
    van Ginneken, Bram
    MEDICAL IMAGING 2010: IMAGE PROCESSING, 2010, 7623
  • [6] Modern Thin-Slice CT Perfusion Has High Sensitivity for Supratentorial Lacunar Stroke
    Thomas, James O.
    Visser, Milanka
    Cordato, Dennis
    Cappelen-Smith, Cecilia
    Esperon, Carlos Garcia
    Sprat, Neil
    Lin, Longting
    Bivard, Andrew
    Parsons, Mark W.
    STROKE, 2024, 55
  • [7] A SIMPLE PERFUSION SYSTEM FOR BRAIN SLICE ELECTROPHYSIOLOGY
    OGATA, N
    INOUE, M
    BRAIN RESEARCH BULLETIN, 1985, 14 (02) : 197 - 198
  • [8] THIN SLICE CT OF THE TEMPORAL BONE
    SHAFFER, KA
    HAUGHTON, VM
    WILSON, CR
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 1979, 3 (04) : 569 - 569
  • [9] Brain CT Perfusion
    Little, K.
    MEDICAL PHYSICS, 2019, 46 (06) : E362 - E363
  • [10] Goliath and the ant: whole-brain CT perfusion against 16-slice CT angiography in stroke imaging
    Morelli, Nicola
    Rota, Eugenia
    Colombi, Davide
    Marchesi, Giuseppe
    Villaggi, Elena
    Giordano, Carlo
    Guidetti, Donata
    Michieletti, Emanuele