Validation of measurement comparability of NaI(Tl) scintillation detectors for radioactive cesium in brown rice sample by interlaboratory comparison

被引:2
|
作者
Miura, Tsutomu [1 ]
Hachinohe, Mayumi [2 ]
Yunoki, Akira [1 ]
Hamamatsu, Shioka [2 ]
Unno, Yasuhiro [1 ]
机构
[1] AIST, Natl Metrol Inst Japan, Tsukuba Cent 3,1-1-1 Umezono, Tsukuba, Ibaraki 3058563, Japan
[2] Natl Agr Res Org, Food Res Inst, 2-1-12 Kannondai, Tsukuba, Ibaraki, Japan
关键词
NaI(Tl) scintillation detector; Brown rice grain; Interlaboratory comparison; Standard limit for radioactive cesium; Accident at the Fukushima Daiichi nuclear power plant; CERTIFIED REFERENCE MATERIAL; FUKUSHIMA ACCIDENT; PERFORMANCE; RADIOCESIUM; CS-134; SR-90;
D O I
10.1007/s10967-020-07373-5
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The interlaboratory comparison that 148 laboratories participated was performed to understand the validity and variability of measurements with NaI(Tl) scintillation detectors for samples near the standard limit for radioactive cesium in general foods in Japan. Brown rice grains with certified massic activity of radioactive cesium were used as test samples. The medians of the reported massic activities of radioactive cesium,Cs-134, and(137)Cs in brown rice grains agreed with the reference values. On the point of view for inspection, more than 92% of the reported values were within the acceptable range.
引用
收藏
页码:1225 / 1231
页数:7
相关论文
共 12 条
  • [1] Validation of measurement comparability of NaI(Tl) scintillation detectors for radioactive cesium in brown rice sample by interlaboratory comparison
    Tsutomu Miura
    Mayumi Hachinohe
    Akira Yunoki
    Shioka Hamamatsu
    Yasuhiro Unno
    Journal of Radioanalytical and Nuclear Chemistry, 2020, 326 : 1225 - 1231
  • [2] Development of a radioactive waste measurement system using arrayed NaI(Tl) detectors
    Yang, Guang
    Shi, Rui
    Wang, Zhou
    Tuo, Xianguo
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2024, 85 (11) : 883 - 889
  • [3] Comparison of two spectrum-dose conversion methods based on NaI(Tl) scintillation detectors
    Yudong, W.
    Xiaobing, L.
    Chi, Z.
    Rong, Z.
    Chaowen, Y.
    JOURNAL OF INSTRUMENTATION, 2018, 13
  • [4] The development of a clearance level radioactive waste measurement system using an array of NaI(Tl) detectors
    Li, C. G.
    Gao, F.
    Sun, H. M.
    Zhao, D. S.
    Su, M.
    Bai, H. Y.
    Xiong, Z. H.
    Mo, Z. H.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2023, 1057
  • [5] Measurement of the sodium and iodine scintillation quenching factors across multiple NaI(Tl) detectors to identify systematics
    Cintas, D.
    Hedges, S.
    Thompson, W. G.
    An, P.
    Awe, C.
    Barbeau, P. S.
    de Souza, E. Barbosa
    Jo, J. H.
    Li, L.
    Martinez, M.
    Maruyama, R. H.
    Rich, G. C.
    Runge, J.
    Sarsa, M. L.
    PHYSICAL REVIEW C, 2024, 110 (01)
  • [6] The Shielding of Radiation for the Detection of Radioactive Cesium in Cereal Sample by Using a NaI (T1) Scintillation Survey Meter
    Kameya, Hiromi
    Hagiwara, Shoji
    Nei, Daisuke
    Kakihara, Yoshiteru
    Kimura, Keitaro
    Matsukura, Ushio
    Kawamoto, Shinichi
    Todoriki, Setsuko
    JOURNAL OF THE JAPANESE SOCIETY FOR FOOD SCIENCE AND TECHNOLOGY-NIPPON SHOKUHIN KAGAKU KOGAKU KAISHI, 2011, 58 (09): : 464 - 469
  • [7] Spectrum-dose conversion operator of NaI(Tl) and CsI(Tl) scintillation detectors for air dose rate measurement in contaminated environments
    Tsuda, Shuichi
    Saito, Kimiaki
    JOURNAL OF ENVIRONMENTAL RADIOACTIVITY, 2017, 166 : 419 - 426
  • [8] The Comparison of Energy Resolution Fitting Functions for 1.5" NaI:Tl, CsI:Tl, LaBr3:Ce, and CeBr3 Scintillation Detectors
    Stribrnsky, Branislav
    Hinca, Robert
    APPLIED PHYSICS OF CONDENSED MATTER (APCOM 2021), 2021, 2411
  • [9] MEASUREMENT OF RADIOACTIVE-TRACER MICROSPHERE BLOOD-FLOW WITH NAI(TL)-WELL AND GE-WELL TYPE DETECTORS
    WINKLER, B
    STAMMLER, G
    SCHAPER, W
    BASIC RESEARCH IN CARDIOLOGY, 1982, 77 (03) : 292 - 300
  • [10] Experimental validation of absolute full energy peak efficiency and energy resolution of NaI(Tl), CsI(Tl), BGO, YAP(Ce) and CeBr3 scintillation detectors modeled with Monte Carlo codes
    Mouhti, Issam
    Mcfee, John Elton
    El-Bouzaidi, Mohamed Drissi
    El Qars, J.
    Ouacha, El Houssaine
    Assakrar, M'hand
    Bellioua, Mohammed
    RADIATION PHYSICS AND CHEMISTRY, 2025, 231