Verification of deep-inspiration breath-hold radiation therapy with respect to reproducibility.

被引:0
|
作者
Freislederer, P. [1 ]
Heinz, C. [1 ]
Walter, F. [1 ]
Schoenecker, S. [1 ]
Parodi, K. [2 ]
Soehn, M. [1 ]
Belka, C. [1 ]
机构
[1] LMU Munchen, Klin & Poliklin Strahlentherapie & Radioonkol, Munich, Germany
[2] LMU Munchen, Lehrstuhl Med Phys, Munich, Germany
关键词
D O I
暂无
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
P-10-08
引用
收藏
页码:S107 / S107
页数:1
相关论文
共 50 条
  • [1] Deep-inspiration breath-hold PET/CT of the thorax
    Nehmeh, Sadek A.
    Erdi, Yusuf E.
    Meirelles, Gustavo S. P.
    Squire, Olivia
    Larson, Steven M.
    Humm, John L.
    Schoder, Heiko
    JOURNAL OF NUCLEAR MEDICINE, 2007, 48 (01) : 22 - 26
  • [2] Dosimetric evaluation of modern radiation therapy techniques for left breast in deep-inspiration breath-hold
    Koivumakia, Tuomas
    Fogliata, Antonella
    Zeverino, Michele
    Boman, Eeva
    Sierpowska, Joanna
    Moeckli, Raphael
    Vallet, Veronique
    Cozzi, Luca
    Heikkila, Janne
    Vaananen, Anssi
    Vuolukka, Kristiina
    Sillanmaki, Saara
    Seppala, Jan
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2018, 45 : 82 - 87
  • [3] Deep-Inspiration Breath-Hold Intensity Modulated Radiation Therapy to the Mediastinum for Lymphoma Patients: Setup Uncertainties and Margins
    Aristophanous, Michalis
    Chi, Pai-Chun M.
    Kao, Jeremy
    Williamson, Ryan
    Tung, Sam
    Andraos, Therese
    Milgrom, Sarah A.
    Pinnix, Chelsea C.
    Dabaja, Bouthaina S.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (01): : 254 - 262
  • [4] The Feasibility of Implementing Deep Inspiration Breath-Hold for Pediatric Radiation Therapy
    Lundgaard, Anni Young
    Josipovic, Mirjana
    Rechner, Laura Ann
    Bidstrup, Pernille Envold
    Hansen, Rune
    Damkjaer, Sidsel Skov
    Joergensen, Morten
    Safwat, Akmal
    Specht, Lena
    Hjalgrim, Lisa Lyngsie
    Maraldo, Maja Vestmoe
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2020, 106 (05): : 977 - 984
  • [5] Accuracy Evaluation of a 3-Dimensional Surface Imaging System for Guidance in Deep-Inspiration Breath-Hold Radiation Therapy
    Alderliesten, Tanja
    Sonke, Jan-Jakob
    Betgen, Anja
    Honnef, Joeri
    van Vliet-Vroegindeweij, Corine
    Remeijer, Peter
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (02): : 536 - 542
  • [6] Deep-Inspiration Breath-Hold Radiation Therapy in Breast Cancer: A Word of Caution on the Dose to the Axillary Lymph Node Levels
    Borm, Kai Joachim
    Oechsner, Markus
    Combs, Stephanie E.
    Duma, Marciana-Nona
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2018, 100 (01): : 263 - 269
  • [7] Clinical implementation of a fluoroscopy guided voluntary deep-inspiration breath-hold radiotherapy
    Van Giersbergen, A.
    Van Beek, S.
    Sonke, J.
    Remeijer, P.
    Borst, G.
    Bartelink, H.
    Van Vliet-Vroegindewij, C.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S152 - S152
  • [8] Deep-Inspiration Breath-Hold Stereotactic Body Radiation Therapy by Combining Spirometer-Guided Breath-Hold and a Real-Time Tumor Tracking System: A Novel Approach
    Tanaka, H.
    Ueda, K.
    Karita, M.
    Ono, T.
    Kajima, M.
    Manabe, Y.
    Sera, T.
    Fujimoto, K.
    Yuasa, Y.
    Shiinoki, T.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2023, 117 (02): : E63 - E64
  • [9] First clinical results of fluoroscopy guided voluntary deep-inspiration breath-hold radiotherapy
    van Vliet-Vroegindewij, C.
    Sonke, J.
    Remeijer, P.
    van Giersbergen, A.
    Betgen, A.
    van Beek, S.
    Bartelink, H.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S168 - S169
  • [10] Radiotherapy in breast cancer with voluntary deep-inspiration breath-hold using BrainLab Exactrac
    Ippolito, E.
    D'Angelillo, R.
    Sicilia, A.
    Silipigni, S.
    Floreno, B.
    Molfese, E.
    Di Donato, A.
    Trecca, P.
    Gaudino, D.
    Stimato, G.
    Ramella, S.
    Trodella, L.
    RADIOTHERAPY AND ONCOLOGY, 2016, 119 : S817 - S817