Test-Retest Reliability of the 40 Hz EEG Auditory Steady-State Response

被引:57
|
作者
McFadden, Kristina L. [1 ,2 ]
Steinmetz, Sarah E. [1 ,2 ]
Carroll, Adam M. [1 ]
Simon, Steven T. [2 ]
Wallace, Alissa [1 ,2 ]
Rojas, Donald C. [1 ,2 ]
机构
[1] Univ Colorado, Dept Psychiat, Aurora, CO 80045 USA
[2] Univ Colorado, Sch Med, Aurora, CO USA
来源
PLOS ONE | 2014年 / 9卷 / 01期
关键词
SCHIZOTYPAL PERSONALITY-DISORDER; GAMMA-BAND ACTIVITY; 1ST-DEGREE RELATIVES; SELECTIVE ATTENTION; COGNITIVE-PROCESSES; BRAIN OSCILLATIONS; FREQUENCY-ANALYSIS; EVOKED-RESPONSES; BIPOLAR DISORDER; MODULATED TONES;
D O I
10.1371/journal.pone.0085748
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Auditory evoked steady-state responses are increasingly being used as a marker of brain function and dysfunction in various neuropsychiatric disorders, but research investigating the test-retest reliability of this response is lacking. The purpose of this study was to assess the consistency of the auditory steady-state response (ASSR) across sessions. Furthermore, the current study aimed to investigate how the reliability of the ASSR is impacted by stimulus parameters and analysis method employed. The consistency of this response across two sessions spaced approximately 1 week apart was measured in nineteen healthy adults using electroencephalography (EEG). The ASSR was entrained by both 40 Hz amplitude-modulated white noise and click train stimuli. Correlations between sessions were assessed with two separate analytical techniques: a) channel-level analysis across the whole-head array and b) signal-space projection from auditory dipoles. Overall, the ASSR was significantly correlated between sessions 1 and 2 (p < 0.05, multiple comparison corrected), suggesting adequate test-retest reliability of this response. The current study also suggests that measures of inter-trial phase coherence may be more reliable between sessions than measures of evoked power. Results were similar between the two analysis methods, but reliability varied depending on the presented stimulus, with click train stimuli producing more consistent responses than white noise stimuli.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] MEG and EEG demonstrate similar test-retest reliability of the 40 Hz auditory steady-state response
    Legget, Kristina T.
    Hild, Allison K.
    Steinmetz, Sarah E.
    Simon, Steven T.
    Rojas, Donald C.
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 2017, 114 : 16 - 23
  • [2] Auditory steady-state responses in normal hearing adults: A test-retest reliability study
    D'haenens, Wendy
    Vinck, Bart M.
    De Vel, Eddy
    Maes, Leen
    Bockstael, Annelies
    Keppler, Hannah
    Philips, Birgit
    Swinnen, Freya
    Dhooge, Ingeborg
    INTERNATIONAL JOURNAL OF AUDIOLOGY, 2008, 47 (08) : 489 - 498
  • [3] Test-retest reliability of mismatch negativity and gamma-band auditory steady-state response in patients with schizophrenia
    Jiao, Xiong
    Hu, Qiang
    Tang, Yingying
    Qian, Zhenying
    Tong, Shanbao
    Wang, Jijun
    Sun, Junfeng
    SCHIZOPHRENIA RESEARCH, 2022, 240 : 165 - 174
  • [4] 40 Hz Auditory Steady-State Response: The Impact of Handedness and Gender
    Melynyte, Sigita
    Pipinis, Evaldas
    Genyte, Vaida
    Voicikas, Aleksandras
    Rihs, Tonia
    Griskova-Bulanova, Inga
    BRAIN TOPOGRAPHY, 2018, 31 (03) : 419 - 429
  • [5] INTRACORTICAL GENERATORS OF THE 40 HZ AUDITORY STEADY-STATE RESPONSE IN THE CAT
    KARMOS, G
    MAKELA, JP
    ULBERT, I
    EUROPEAN JOURNAL OF NEUROSCIENCE, 1992, : 145 - 145
  • [6] CLINICAL USE OF THE 40-HZ AUDITORY STEADY-STATE RESPONSE
    PLOURDE, G
    INTERNATIONAL ANESTHESIOLOGY CLINICS, 1993, 31 (04) : 107 - 120
  • [7] INTRACORTICAL COMPONENTS OF THE 40 HZ AUDITORY STEADY-STATE RESPONSE IN THE CAT
    KARMOS, G
    MAKELA, JP
    ULBERT, I
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 1993, 14 (02) : 131 - 131
  • [8] 40 Hz Auditory Steady-State Response: The Impact of Handedness and Gender
    Sigita Melynyte
    Evaldas Pipinis
    Vaida Genyte
    Aleksandras Voicikas
    Tonia Rihs
    Inga Griskova-Bulanova
    Brain Topography, 2018, 31 : 419 - 429
  • [9] 40 Hz Auditory steady-state response and EEG spectral edge frequency during sufentanil anaesthesia
    I. Gilron
    G. Plourde
    W. Marcantoni
    F. Varin
    Canadian Journal of Anaesthesia, 1998, 45 : 115 - 121
  • [10] 40 Hz auditory steady-state response and EEG spectral edge frequency during sufentanil anaesthesia
    Gilron, I
    Plourde, G
    Marcantoni, W
    Varin, F
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 1998, 45 (02): : 115 - 121