共 5 条
Improved techniques for measurement of nanolitre volumes of phloem exudate from aphid stylectomy
被引:10
|作者:
Palmer, Lachlan J.
[1
]
Palmer, Lyndon T.
[2
]
Pritchard, Jeremy
[3
]
Graham, Robin D.
[1
]
Stangoulis, James Cr
[1
]
机构:
[1] Flinders Univ S Australia, Sch Biol Sci, Bedford Pk, SA 5042, Australia
[2] Univ Adelaide, Sch Agr Food & Wine, Adelaide, SA 5064, Australia
[3] Univ Birmingham, Sch Biosci, Birmingham B15 2TT, W Midlands, England
来源:
关键词:
Aphid stylectomy;
Exudate;
Phloem;
Volume measurement;
MOUTH-PARTS;
AMINO-ACID;
SIEVE TUBE;
SAP;
TRANSPORT;
PROTEINS;
NITROGEN;
SUGAR;
WHEAT;
D O I:
10.1186/1746-4811-9-18
中图分类号:
Q5 [生物化学];
学科分类号:
071010 ;
081704 ;
摘要:
Background: When conducting aphid stylectomy, measuring accurate rates of phloem exudation is difficult because the volumes collected are in the nanolitre (nl) range. In a new method, exudate volume was calculated from optical measurement of droplet diameter as it forms on the tip of a severed aphid stylet. Evaporation was shown to decrease the accuracy of the measurement but was countered with the addition of water-saturated mineral oil. Volume measurements by optical estimation of the volume of a sphere suspended in oil was affected by the curvature of the oil surface. In contrast, measuring the exudate volume from optical measurement of droplet-diameter as formed on the tip of a severed aphid stylet, removes any inaccuracies due to oil surface curvature. A modified technique is proposed for measuring exudate volumes without oil by estimating the flow rate from photo-sequences of the collection period; a correction for evaporation is applied later. Results: A change in oil volume of +/- 1.75% from an optimum volume of 285 mu l had a statistically significant effect on droplet measurement, under or over-estimating droplet volume due to optical effects caused by the oil surface. Using microscope image capture and measurement software, a modified method for measuring phloem volume in air was developed, by reducing air exposure during measurement to approximately 5 s for each measurement. Phloem volumes were measured using both techniques with measurements in air being on average 19.9 nl less (SD 18.87, p<0.001) than those made in oil, and there was a strong linear relationship (R-2=0.942) between the techniques. This linear relationship enabled the development of a correction equation with no significant difference at the 5% level between corrected volumes and actual volumes measured under oil. Conclusions: This study showed that oil has a significant role in countering evaporation but oil volume must be carefully optimised for optical measurement of droplets to ensure measurement accuracy. A linear correction factor was generated to correct the volumes measured in air for loss due to evaporation and the method provides for a much simpler alternative to previous approaches for measuring exudation rates and volumes from a cut aphid stylet.
引用
收藏
页数:7
相关论文