Non-linear Modeling of Oil-paper Insulation for Condition Assessment using Non-sinusoidal Excitation

被引:11
|
作者
Pradhan, A. [1 ]
Koley, C. [2 ]
Chatterjee, B. [3 ]
Chakravorti, S. [3 ]
机构
[1] Jadavpur Univ, Dept Elect Engn, Kolkata 700032, India
[2] Natl Inst Technol, Dept Elect Engn, Durgapur 713209, India
[3] Jadavpur Univ, Dept Elect Engn, Kolkata 700032, India
关键词
System identification; nonlinear systems; frequency domain spectroscopy; Hammerstein model; insulation condition monitoring; transformer oil-paper insulator; FREQUENCY-DOMAIN; DIELECTRIC-SPECTROSCOPY; TIME; IDENTIFICATION; PARAMETERS; POLARIZATION;
D O I
10.1109/TDEI.2015.004504
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In high voltage engineering, dielectric response analysis is a widely used tool for insulation diagnostic. Voltages used for studying dielectric response in the laboratory are usually sinusoidal in nature. But the insulation system in operation on site is often stressed by voltages that may deviate significantly from a sinusoid. Thus the use of non-sinusoidal waveform in obtaining the dielectric response is a desirable study for advanced insulation diagnostic technique. Present work involves assessing the condition of electrical insulation using dielectric response analysis under the influence of non-sinusoidal voltage waveform. In dielectric response analysis, characteristics curve of phase response over a frequency band is used to predict the insulation condition, which involves expertise. In this respect parameterization of insulation condition can make the assessment technique much simpler. But the nonlinear behavior of insulation restricts such an attempt to be accurate enough for reliable assessment of minute degradation of insulation condition. Therefore, the present work proposes a non-linear system identification technique, in an attempt to parameterize insulation condition. In this work, a suitable excitation signal has been designed so that the observed response becomes representative of the behavior of the whole system dynamics over the frequency band of interest. Tests have been performed with insulations having different moisture contents. The obtained system parameters, through nonlinear Hammerstein model, were found to be consistent over several experiments, and also accurate enough to detect small variation of moisture content. The proposed method is based on the time domain measurement of input excitation voltage and corresponding response current through the insulation.
引用
收藏
页码:2165 / 2175
页数:11
相关论文
共 50 条
  • [1] Effect of Temperature on Frequency Dependent Dielectric Parameters of Oil-paper Insulation Under Non-sinusoidal Excitation
    Pradhan, A. K.
    Chatterjee, B.
    Chakravorti, S.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (02) : 653 - 661
  • [2] Reducing frequency domain spectroscopy measurement time for condition monitoring of transformer oil-paper insulation using non-sinusoidal excitations
    Chatterjee, Soumya
    Pradhan, Arpan Kumar
    Dalai, Sovan
    Chatterjee, Biswendu
    Chakravorti, Sivaji
    IET SCIENCE MEASUREMENT & TECHNOLOGY, 2017, 11 (02) : 204 - 212
  • [3] Estimation of Paper Moisture Content based on Dielectric Dissipation Factor of Oil-paper Insulation under Non-sinusoidal Excitations
    Pradhan, A. K.
    Chatterjee, B.
    Chakravorti, S.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2015, 22 (02) : 822 - 830
  • [4] Insulation Assessment Based on Dielectric Dissipation Factor Measurement under Non-sinusoidal Excitation
    Muntakim, Pratic A.
    Zhang, Shubin
    Zhang, Junyang
    Phung, B. T.
    PROCEEDINGS OF 2021 5TH INTERNATIONAL CONFERENCE ON CONDITION ASSESSMENT TECHNIQUES IN ELECTRICAL SYSTEMS (IEEE CATCON 2021), 2021, : 242 - 246
  • [5] Determination of Optimized Slope of Triangular Excitation for Condition Assessment of Oil-paper Insulation by Frequency Domain Spectroscopy
    Pradhan, A. K.
    Koley, C.
    Chatterjee, B.
    Calravorti, S.
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (03) : 1303 - 1312
  • [6] The assessment of oil-paper insulation condition based on frequency response method
    Liu, Jun
    Wu, Guang-ning
    Lv, Wei
    Zhou, Li-jun
    Min, Ying-jie
    2010 ANNUAL REPORT CONFERENCE ON ELECTRICAL INSULATION AND DIELECTIC PHENOMENA, 2010,
  • [7] Analysis of nonlinear electric field of oil-paper insulation under non-sinusoidal voltage by the fixed-point harmonic-balanced decomposition FEM
    Liu, Gang
    Jin, Zhiming
    Zhao, Xiaojun
    Yuan, Dongwei
    Li, Lin
    INTERNATIONAL JOURNAL OF APPLIED ELECTROMAGNETICS AND MECHANICS, 2019, 60 (03) : 393 - 407
  • [8] PERFORMANCE OF NON-LINEAR STRESS-GRADING SYSTEMS AT NON-SINUSOIDAL VOLTAGES
    El-Kishky, H.
    El-Said, A.
    Brown, F.
    PROCEEDINGS OF THE 2008 IEEE INTERNATIONAL POWER MODULATORS AND HIGH VOLTAGE CONFERENCE, 2008, : 307 - +
  • [9] Effect of Temperature on Condition Assessment of Oil-Paper Insulation using Polarization-Depolarization Current
    Saurabh
    Mukherjee, M.
    Pradhan, A. K.
    Baral, A.
    Chakravorti, S.
    2016 NATIONAL POWER SYSTEMS CONFERENCE (NPSC), 2016,
  • [10] Insulation Condition Diagnosis of Oil-Immersed Paper Insulation Based on Non-linear Frequency-Domain Dielectric Response
    Zhang, Daning
    Yun, Hao
    Zhan, Jiangyang
    Sun, Xiang
    He, Wenlin
    Niu, Chaobin
    Mu, Haibao
    Zhang, Guan-jun
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2018, 25 (05) : 1980 - 1988