Reproducibility of isokinetic knee eccentric and concentric strength indices in asymptomatic young adults

被引:30
|
作者
Almosnino, Sivan [1 ,2 ,3 ]
Stevenson, Joan M. [1 ,2 ,3 ]
Bardana, Davide D. [2 ,3 ,4 ]
Diaconescu, Elena D. [2 ,3 ]
Dvir, Zeevi [1 ,5 ]
机构
[1] Queens Univ, Sch Kinesiol & Hlth Studies, Biomech & Ergon Lab, Kingston, ON K7L 3N6, Canada
[2] Queens Univ, Kingston, ON K7L 2V7, Canada
[3] Kingston Gen Hosp, Syl & Molly Apps Med Res Ctr, Human Mobil Res Ctr, Kingston, ON K7L 2V7, Canada
[4] Kingston Gen Hosp, Div Orthopaed Surg, Kingston, ON K7L 2V6, Canada
[5] Tel Aviv Univ, Sackler Fac Med, Dept Phys Therapy, IL-69978 Ramat Aviv, Israel
基金
加拿大自然科学与工程研究理事会;
关键词
Reliability of results; Muscle strength; Resistance training; SPORTS-MEDICINE; TESTING PROTOCOL; HAMSTRING INJURY; MUSCLE STRENGTH; SOCCER PLAYERS; RELIABILITY; DYNAMOMETER; PERFORMANCE; EXTENSION; FLEXION;
D O I
10.1016/j.ptsp.2011.09.002
中图分类号
R49 [康复医学];
学科分类号
100215 ;
摘要
Objective: To assess the reproducibility of isokinetic eccentric and concentric knee extension and flexion strength indices obtained at two different angular velocities. Design: Cohort study. Setting: University human performance laboratory. Participants: 45 healthy physically active young adults (25 males). Main outcome measures: A non reciprocal protocol of concentric and eccentric contractions of the knee extensors and flexors was performed at 30 and 120 degrees/s. Strength indices evaluated included peak moment; dynamic control ratios; and the difference between eccentric and concentric ratio at the two angular velocities. Results: No evidence for inter-test bias in any of the strength indices was noted. Measurement precision for peak moment, as quantified using ratio limits of agreement, suggest that scores may be expected to vary up to 15% for the knee extensors in both eccentric and concentric contraction modes. An error of up to 19% was calculated for the peak moment scores of the knee flexors. Intraclass correlation coefficients revealed fairly robust preservation of participants' rank order for the majority of strength indices (>0.85). Conclusion: Isokinetic-related indices of knee muscles performance enable an acceptable level of detection of expected changes in muscular strength parameters as a result of planned interventions. (C) 2011 Elsevier Ltd. All rights reserved.
引用
收藏
页码:156 / 162
页数:7
相关论文
共 50 条
  • [1] Reproducibility of concentric and eccentric isokinetic strength of the knee flexors in elite volleyball players
    Dauty, M
    Rochcongar, P
    ISOKINETICS AND EXERCISE SCIENCE, 2001, 9 (2-3) : 129 - 132
  • [2] Reproducibility Of Isokinetic Strength Assessment Of Knee Extensors And Flexors Adopting Concentric And Eccentric Contractions
    Duarte, Joao Pedro
    Valente-dos-Santos, Joao
    Costa, Daniela
    Sousa-e-Silva, Paulo
    Martinho, Diogo
    Cyrino, Edilson
    Seabra, Andre
    Soles-Goncalves, Rui
    Coelho-e-Silva, Manuel
    MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2018, 50 (05): : 568 - 568
  • [3] Bilateral isokinetic concentric and eccentric strength profiles of the knee extensors and flexors in young soccer players
    Kellis, S
    Gerodimos, V
    Kellis, E
    Manou, V
    ISOKINETICS AND EXERCISE SCIENCE, 2001, 9 (01) : 31 - 39
  • [4] RELIABILITY OF ISOKINETIC ECCENTRIC AND CONCENTRIC KNEE EXTENSIONS
    CARTER, CL
    BEKENDAM, JT
    CASSIDY, ML
    ROGOUSKI, MA
    PHYSICAL THERAPY, 1987, 67 (05): : 752 - 753
  • [5] Concentric and eccentric isokinetic knee extension: A reproducibility study using the IsoMed 2000-dynamometer
    Dirnberger, Johannes
    Koesters, Alexander
    Mueller, Erich
    ISOKINETICS AND EXERCISE SCIENCE, 2012, 20 (01) : 31 - 35
  • [6] Reproducibility of concentric isokinetic strength of the knee extensors and flexors in individuals with mild and moderate osteoarthritis of the knee
    Germanou, E.
    Beneka, A.
    Malliou, P.
    Tsiganos, G.
    Papalexandris, St.
    Bikos, Ch.
    Godolias, G.
    ISOKINETICS AND EXERCISE SCIENCE, 2007, 15 (03) : 151 - 164
  • [7] Continuous versus separate isokinetic test protocol:: The effect of estradiol on the reproducibility of concentric and eccentric isokinetic measurements in knee muscles
    Gür, H
    Akova, B
    Kücükoglu, S
    ARCHIVES OF PHYSICAL MEDICINE AND REHABILITATION, 1999, 80 (09): : 1024 - 1029
  • [8] Cardiovascular stress associated with concentric and eccentric isokinetic exercise in young and older adults
    Overend, TJ
    Versteegh, TH
    Thompson, E
    Birmingham, TB
    Vandervoort, AA
    JOURNALS OF GERONTOLOGY SERIES A-BIOLOGICAL SCIENCES AND MEDICAL SCIENCES, 2000, 55 (04): : B177 - B182
  • [9] ISOKINETIC ASSESSMENT OF CONCENTRIC AND ECCENTRIC SHOULDER ROTATION STRENGTH
    NG, LR
    KRAMER, JF
    PHYSICAL THERAPY, 1988, 68 (05): : 836 - 836
  • [10] A NEW DYNAMOMETER MEASURING CONCENTRIC AND ECCENTRIC MUSCLE STRENGTH IN ACCELERATED, DECELERATED, OR ISOKINETIC MOVEMENTS - VALIDITY AND REPRODUCIBILITY
    SEGER, JY
    WESTING, SH
    HANSON, M
    KARLSON, E
    EKBLOM, B
    EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 1988, 57 (05) : 526 - 530