Efficacy of continuous positive airway pressure for obstructive sleep apnea in overweight patients with type 2 diabetes mellitus

被引:0
|
作者
Chen, Liang [1 ]
Kuang, Jian [1 ]
Pei, Jian-Hao [1 ]
Chen, Hong-Mei [1 ]
Chen, Zhong [1 ]
Li, Zhong-Wen [1 ]
Yang, Hua-Zhang [1 ]
Fu, Xiao-Ying [1 ]
Wang, Long [1 ]
Chen, Zhi-Jiang [1 ]
Lai, Shui-Qing [1 ]
机构
[1] Guangdong Acad Med Sci, Guangdong Gen Hosp, Dept Endocrinol, Div 1, 106th Zhongshan Er Rd, Guangzhou 510080, Guangdong, Peoples R China
关键词
Continuous positive airway pressure; obstructive sleep apnea; overweight; type 2 diabetes mellitus; METABOLIC SYNDROME; INTERMITTENT HYPOXIA; GLUCOSE-METABOLISM; INSULIN-RESISTANCE; TREATMENT SATISFACTION; CARDIOVASCULAR RISK; OBESE-PATIENTS; NORMAL-WEIGHT; HEART HEALTH; CPAP;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Although the association between obstructive sleep apnea (OSA) and type 2 diabetes mellitus (T2DM) is well-established, the impact of continuous positive airway pressure (CPAP) therapy on glycemic control or metabolic profiles in T2DM patients with OSA is unclear. The objective of this study was to investigate metabolism-related parameters and diabetes treatment satisfaction following CPAP therapy for OSA in overweight patients with T2DM or impaired glycemic tolerance. This retrospective study included 16 overweight patients treated with CPAP for OSA by comparison of laboratory and anthropometric data between baseline (3 months before initiation of CPAP treatment) and at 3-and 6-months post-treatment, and by psychometric scores of DM treatment satisfaction using the Diabetes Treatment Satisfaction Questionnaire (DTSQ). Significant reductions in body weight and waist circumference were observed after initiating CPAP therapy (both P<0.001). Mean glycosylated hemoglobin (HbA1c) level measured at 3 months after CPAP therapy was lower than the baseline assessment, and the mean HbA1c level at 6 months post-treatment was lower than that at 3 months post-treatment (both P<0.05). In addition, fasting and postprandial plasma glucose levels decreased significantly at 3 months after CPAP therapy, remaining stable at 6 months (P=0.009). Furthermore, significant decreases in fasting insulin level (P=0.037), postprandial insulin level (P<0.001), and triglyceride level (P=0.002) were observed following CPAP. Finally, satisfaction with diabetes treatment improved significantly following initiation of CPAP therapy (P<0.001). CPAP for OSA improved anthropomorphic measures as well as glycemic control, insulin sensitivity and diabetes treatment satisfaction in overweight patients with T2DM or abnormal glucose metabolism.
引用
收藏
页码:19858 / 19864
页数:7
相关论文
共 50 条
  • [1] Efficacy of continuous positive airway pressure on arrhythmias in obstructive sleep apnea patients
    Hidetoshi Abe
    Masafumi Takahashi
    Hironobu Yaegashi
    Seiichiro Eda
    Hideo Tsunemoto
    Mamoru Kamikozawa
    Jun Koyama
    Kyohei Yamazaki
    Uichi Ikeda
    Heart and Vessels, 2010, 25 (1) : 63 - 69
  • [2] Efficacy of continuous positive airway pressure on arrhythmias in obstructive sleep apnea patients
    Abe, Hidetoshi
    Takahashi, Masafumi
    Yaegashi, Hironobu
    Eda, Seiichiro
    Tsunemoto, Hideo
    Kamikozawa, Mamoru
    Koyama, Jun
    Yamazaki, Kyohei
    Ikeda, Uichi
    HEART AND VESSELS, 2010, 25 (01) : 63 - 69
  • [3] Type 2 diabetes, glycemic control, and continuous positive airway pressure in obstructive sleep apnea
    Babu, AR
    Herdegen, J
    Fogelfeld, L
    Shott, S
    Mazzone, T
    ARCHIVES OF INTERNAL MEDICINE, 2005, 165 (04) : 447 - 452
  • [4] Impact of Continuous Positive Airway Pressure Compliance on Complications in Patients with Type 2 Diabetes and Obstructive Sleep Apnea
    Reutrakul, Sirimon
    Prasad, Bharati
    Sahni, Ashima
    Matani, Sara
    Sheth, Urmi
    Danielson, Kirstie K.
    Monson, Rebecca S.
    Carlucci, Melissa
    Mercado, Tomas
    Smith, Maureen
    DIABETES, 2020, 69
  • [5] Association of continuous positive airway pressure adherence with complications in patients with type 2 diabetes and obstructive sleep apnea
    Sheth, Urmi
    Monson, Rebecca S.
    Prasad, Bharati
    Sahni, Ashima S.
    Matani, Sara
    Mercado, Tomas
    Smith, Maureen A.
    Carlucci, Melissa A.
    Danielson, Kirstie K.
    Reutrakul, Sirimon
    JOURNAL OF CLINICAL SLEEP MEDICINE, 2021, 17 (08): : 1563 - 1569
  • [6] Effectiveness Of Positive Airway Pressure In Type 2 Diabetes And Obstructive Sleep Apnea
    Donovan, L. M.
    Rueschman, M.
    Basu, N. A.
    Weng, J.
    Dudley, K. A.
    Bakker, J. P.
    Wang, R.
    Bertisch, S.
    Patel, S. R.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2016, 193
  • [7] Treating Obstructive Sleep Apnea With Continuous Positive Airway Pressure Benefits Type 2 Diabetes Management
    Zhong, Weiguang
    Tang, Yongming Gorge
    Zhao, Xiaoning
    Go, Frisca Yan
    Harper, Ronald M.
    Hui, Hongxiang
    PANCREAS, 2014, 43 (03) : 325 - 330
  • [8] Effects of continuous positive airway pressure treatment on sleep architecture in adults with obstructive sleep apnea and type 2 diabetes
    Wilckens, Kristine A.
    Jeon, Bomin
    Morris, Jonna L.
    Buysse, Daniel J.
    Chasens, Eileen R.
    FRONTIERS IN HUMAN NEUROSCIENCE, 2022, 16
  • [9] Continuous positive airway pressure for obstructive sleep apnea
    Basner, Robert C.
    NEW ENGLAND JOURNAL OF MEDICINE, 2007, 356 (17): : 1751 - 1758
  • [10] Continuous positive airway pressure in obstructive sleep apnea
    Meurice, Jean Claude
    Antone, Elise
    Gilbert, Mylene
    Watrin, Audrey
    Bironneau, Vanessa
    PRESSE MEDICALE, 2017, 46 (04): : 423 - 431