Determination of enantiomeric impurity in besifloxacin hydrochloride by chiral high-performance liquid chromatography with precolumn derivatization

被引:20
|
作者
Wang, Zhangting [1 ]
Wang, Shengjia [1 ]
Zhu, Feng [2 ]
Chen, Zaixin [2 ]
Yu, Lushan [1 ]
Zeng, Su [1 ]
机构
[1] Zhejiang Univ, Coll Pharmaceut Sci, Hangzhou 310058, Zhejiang, Peoples R China
[2] Jiangsu Yabang Pharmaceut Grp Co Ltd, R&D Ctr, Jintan, Jiangsu, Peoples R China
关键词
besifloxacin hydrochloride; enantiomer; precolumn derivatization; chiral; enantiomeric impurity; STATIONARY-PHASE; CROWN-ETHER; FLUOROQUINOLONE ANTIBACTERIALS; SEPARATION; GEMIFLOXACIN; OFLOXACIN; HPLC;
D O I
10.1002/chir.22042
中图分类号
R914 [药物化学];
学科分类号
100701 ;
摘要
Besifloxacin hydrochloride is a novel chiral broad-spectrum fluoroquinolone developed for the treatment of bacterial conjunctivitis. R-besifloxacin hydrochloride is used in clinics as a consequence of its higher antibacterial activity. To establish an enantiomeric impurity determination method, some chiral stationary phases (CSPs) were screened. Besifloxacin enantiomers can be separated to a certain extent on Chiral CD-Ph (Shiseido Co., Ltd., Japan), Chiral AGP, and Crownpak CR (+) (Daicel Chemical IND., Ltd., Japan). However, the selectivity and sensitivity were both unsatisfactory on these three CSPs. Therefore, Chiral AGP, Chiral CD-Ph, and Crownpak CR (+) were not used in the enantiomeric impurity determination of besifloxacin hydrochloride. The separation of enantiomers of besifloxacin was further performed using a precolumn derivatization chiral high-performance liquid chromatography method. 2,3,4,6-Tetra-O-acetyl-beta-D-glucopyranosyl isothiocyanate was used as the derivatization reagent. Besifloxacin enantiomer derivates were well separated on a C18 column (250 x 4.6?mm, 5 mu m) with a mobile phase that consisted of methanol-KH2PO4 buffer solution (20?mM; pH?3.0) (50:50, v/v). Selectivity, sensitivity, linearity, accuracy, precision, stability, and robustness of this method were all satisfied with the method validation requirement. The method was suitable for the quality control of enantiomeric impurity in besifloxacin hydrochloride. Chirality 24:526531, 2012. (C) 2012 Wiley Periodicals, Inc.
引用
收藏
页码:526 / 531
页数:6
相关论文
共 50 条
  • [1] DETERMINATION OF NITRITE BY PRECOLUMN DERIVATIZATION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    VERMA, KK
    VERMA, A
    ANALYTICAL LETTERS, 1992, 25 (11) : 2083 - 2093
  • [2] Enantiomeric determination of amines by high-performance liquid chromatography using chiral fluorescent derivatization reagents
    Al-Kindy, S
    Santa, T
    Fukushima, T
    Homma, H
    Imai, K
    BIOMEDICAL CHROMATOGRAPHY, 1998, 12 (05) : 276 - 280
  • [3] DETERMINATION OF AMPICILLIN IN SERUM BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PRECOLUMN DERIVATIZATION
    LAL, J
    PALIWAL, JK
    GROVER, PK
    GUPTA, RC
    JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1994, 655 (01): : 142 - 146
  • [4] DETERMINATION OF IODIDE BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY AFTER PRECOLUMN DERIVATIZATION
    VERMA, KK
    JAIN, A
    VERMA, A
    ANALYTICAL CHEMISTRY, 1992, 64 (13) : 1484 - 1489
  • [5] Determination of carbohydrazide by high performance liquid chromatography with precolumn derivatization
    Wu, T
    Zhang, TL
    Sun, YH
    Zhang, JG
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2004, 32 (12) : 1639 - 1640
  • [6] Determination of fluoxetine hydrochloride enantiomeric excess using high-performance liquid chromatography with chiral stationary phases
    Olsen, BA
    Wirth, DD
    Larew, JS
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 1998, 17 (4-5) : 623 - 630
  • [7] Determination of Sulfonamides in Feeds by High-Performance Liquid Chromatography after Fluorescamine Precolumn Derivatization
    Patyra, Ewelina
    Przenioslo-Siwczynska, Monika
    Kwiatek, Krzysztof
    MOLECULES, 2019, 24 (03)
  • [8] Determination of Amitrole in Environmental Water Samples with Precolumn Derivatization by High-Performance Liquid Chromatography
    Sun, Yan
    Liu, Peng Fei
    Wang, Deng
    Li, Jian Qiang
    Cao, Yong Song
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2009, 57 (11) : 4540 - 4544
  • [10] DETERMINATION OF A BIGUANIDE, METFORMIN, BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY WITH PRECOLUMN FLUORESCENCE DERIVATIZATION
    OHTA, M
    IWASAKI, M
    KAI, M
    OHKURA, Y
    ANALYTICAL SCIENCES, 1993, 9 (02) : 217 - 220