Chiral electrochemical sensing for tyrosine enantiomers on glassy carbon electrode modified with cysteic acid

被引:59
|
作者
Nie, Runqiu [1 ]
Bo, Xiangjie [1 ]
Wang, Huan [1 ]
Zeng, Lijun [1 ]
Guo, Liping [1 ]
机构
[1] NE Normal Univ, Fac Chem, Changchun 130024, Peoples R China
基金
中国国家自然科学基金;
关键词
Chiral electrochemical recognition; Tyrosine; Cysteic acid; Modified electrode; ENANTIOSELECTIVE RECOGNITION; VOLTAMMETRIC DETERMINATION; SENSITIVE DETERMINATION; AMINO-ACIDS; BEHAVIOR;
D O I
10.1016/j.elecom.2012.11.014
中图分类号
O646 [电化学、电解、磁化学];
学科分类号
081704 ;
摘要
A chiral electrochemical sensor has been prepared via cysteic acid modified glassy carbon (CyA-GC) electrode to discriminate tyrosine (Tyr) enantiomers. Sweep cycles of CyA-GC in modification process and pH of solution were investigated to obtain optimum experimental conditions. Electrochemical impedance spectroscopy was employed to characterize the electrical conductivity of the modified electrode. For the first time, different oxidation peak potentials (E-p) of L- and D-Tyr were observed in the differential pulse voltammograms obtained in the solution containing L- or D-Tyr. Further study showed that only one peak appeared in mixture solution containing L- and D-Tyr and E-p of that peak shifted positively and linearly with an increasing percentage of L-isomer of Tyr racemic mixture. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:112 / 115
页数:4
相关论文
共 50 条
  • [1] Determination of Theophylline at a Cysteic Acid Modified Glassy Carbon Electrode
    Brunetti, Barbara
    Desimoni, Elio
    ELECTROANALYSIS, 2009, 21 (06) : 772 - 778
  • [2] Chiral recognition of tyrosine enantiomers on a novel bis-aminosaccharides composite modified glassy carbon electrode
    Zou, Jiao
    Yu, Jin-Gang
    ANALYTICA CHIMICA ACTA, 2019, 1088 : 35 - 44
  • [3] Simultaneous determination of L-DOPA, L-tyrosine and uric acid by cysteic acid - modified glassy carbon electrode
    Hassanvand, Zahra
    Jalali, Fahimeh
    MATERIALS SCIENCE AND ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2019, 98 : 496 - 502
  • [4] Determination of isoniazid content via cysteic acid/graphene modified glassy carbon electrode
    Si, Xiaojing
    Jiang, Lin
    Wang, Xinyue
    Ding, Yaping
    Luo, Liqiang
    ANALYTICAL METHODS, 2015, 7 (02) : 793 - 798
  • [5] Voltammetric determination of sinomenine at glassy carbon electrode modified by cysteic acid based on electrochemical oxidation of L-cysteine
    Guan, Jun
    Wang, Zhixian
    Wang, Chengyin
    Qu, Qishu
    Yang, Gongjun
    Hu, Xiaoya
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2007, 2 (08): : 572 - 582
  • [6] Electrochemical Sensing of Theophylline using Modified Glassy Carbon Electrode
    Pour, Effat Sharifi
    Ebrahimi, Maryam
    Beitollahi, Hadi
    CHEMICAL METHODOLOGIES, 2022, 6 (07): : 560 - 568
  • [7] Stearic acid modified glassy carbon electrode for electrochemical sensing of parathion and methyl parathion
    Nirmala, J. Nancy
    Kumaravel, A.
    Chandrasekaran, M.
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (08) : 1571 - 1574
  • [8] Stearic acid modified glassy carbon electrode for electrochemical sensing of parathion and methyl parathion
    J. Nancy Nirmala
    A. Kumaravel
    M. Chandrasekaran
    Journal of Applied Electrochemistry, 2010, 40 : 1571 - 1574
  • [9] Acylpyrazolone Modified Glassy Carbon Electrode Effect on the Electrochemical Behavior of Tyrosine
    Zhang Dan
    Li Jin-zhou
    ANALYTICAL LETTERS, 2008, 41 (15) : 2832 - 2843
  • [10] Chiral electrochemical recognition of tryptophan enantiomers at a multi-walled carbon nanotube-chitosan composite modified glassy carbon electrode
    Yu, Lin-Yan
    Liu, Qi
    Wu, Xiong-Wei
    Jiang, Xin-Yu
    Yu, Jin-Gang
    Chen, Xiao-Qing
    RSC ADVANCES, 2015, 5 (119): : 98020 - 98025