One-step immunoassay of C-reactive protein using droplet microfluidics

被引:51
|
作者
Tang, Matthew Y. H. [1 ]
Shum, Ho Cheung [1 ,2 ]
机构
[1] Univ Hong Kong, Dept Mech Engn, Pokfulam Rd, Hong Kong, Hong Kong, Peoples R China
[2] HKU Shenzhen Inst Res & Innovat HKU SIRI, Shenzhen 518000, Guangdong, Peoples R China
基金
中国国家自然科学基金;
关键词
CARDIOVASCULAR-DISEASE; HIGH-THROUGHPUT; PLATFORM; ELISA; RISK; INFLAMMATION; TECHNOLOGY; SYSTEM; CELLS;
D O I
10.1039/c6lc01121g
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We present a wash-free high-sensitivity immunoassay of C-reactive proteins with droplet microfluidics. Microbeads are encapsulated within droplets for the immunoassay, and the droplets are scanned by a fluorescence detection platform to quantify the amount of proteins captured on the microbeads. The limit of detection determined by our platform is 0.01 mu g mL(-1), which is ten times more sensitive than conventional high-sensitivity C-reactive protein assays. With the decrease in diffusion distance within droplets, the immunoassay requires only half of the time required for similar conventional approaches. This approach for carrying out immunoassays can potentially be applied to other biomarkers beyond C-reactive proteins.
引用
收藏
页码:4359 / 4365
页数:7
相关论文
共 50 条
  • [1] One-step homogeneous C-reactive protein assay for saliva
    Punyadeera, Chamindie
    Dimeski, Goce
    Kostner, Karam
    Beyerlein, Peter
    Cooper-White, Justin
    JOURNAL OF IMMUNOLOGICAL METHODS, 2011, 373 (1-2) : 19 - 25
  • [2] ONE-STEP PREPARATION OF BOTH HUMAN C-REACTIVE PROTEIN AND CIT
    PONTET, M
    ENGLER, R
    JAYLE, MF
    FEBS LETTERS, 1978, 88 (02) : 172 - 175
  • [3] One-step non-competitive fluorescence polarization immunoassay based on a Fab fragment for C-reactive protein quantification
    Nishiyama, Keine
    Fukuyama, Mao
    Maeki, Masatoshi
    Ishida, Akihiko
    Tani, Hirofumi
    Hibara, Akihide
    Tokeshi, Manabu
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 326
  • [4] Magnetic chemiluminescent immunoassay for human C-reactive protein on the centrifugal microfluidics platform
    Czilwik, G.
    Vashist, S. K.
    Klein, V.
    Buderer, A.
    Roth, G.
    von Stetten, F.
    Zengerle, R.
    Mark, D.
    RSC ADVANCES, 2015, 5 (76): : 61906 - 61912
  • [5] One-step kinetics-based immunoassay for the highly sensitive detection of C-reactive protein in less than 30 min
    Vashist, Sandeep Kumar
    Czilwik, Gregor
    van Oordt, Thomas
    von Stetten, Felix
    Zengerle, Roland
    Schneider, E. Marion
    Luong, John H. T.
    ANALYTICAL BIOCHEMISTRY, 2014, 456 : 32 - 37
  • [6] A facile one-step gold nanoparticles enhancement based on sequential patterned lateral flow immunoassay device for C-reactive protein detection
    Panraksa, Yosita
    Apilux, Amara
    Jampasa, Sakda
    Puthong, Songchan
    Henry, Charles S.
    Rengpipat, Sirirat
    Chailapakul, Orawon
    SENSORS AND ACTUATORS B-CHEMICAL, 2021, 329
  • [7] ONE-STEP RT-PCR FOR DETECTION OF MICRORNAS IN EXOSOMES USING DROPLET MICROFLUIDICS
    Cui, Binbin
    Liu, Chunchen
    Yao, Shuhuai
    2020 33RD IEEE INTERNATIONAL CONFERENCE ON MICRO ELECTRO MECHANICAL SYSTEMS (MEMS 2020), 2020, : 142 - 146
  • [8] Sensitive Detection of C-Reactive Protein by One-Step Method Based on a Waveguide-Mode Sensor
    Ashiba, Hiroki
    Oyamada, Chiaki
    Hosokawa, Kazuya
    Ueno, Koji
    Fujimaki, Makoto
    SENSORS, 2020, 20 (11)
  • [9] Rapid one-step whole blood C-reactive protein magnetic permeability immunoassay with monoclonal antibody conjugated nanoparticles as superparamagnetic labels and enhanced sedimentation
    Ibraimi, F
    Kriz, D
    Lu, M
    Hansson, LO
    Kriz, K
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2006, 384 (03) : 651 - 657
  • [10] ENZYME-IMMUNOASSAY OF C-REACTIVE PROTEIN
    KIM, SV
    YUDIN, KB
    TRUNOVA, LA
    LABORATORNOE DELO, 1990, (09): : 45 - 48