X-ray phase-shifts-based method of volumetric breast density measurement

被引:11
|
作者
Wu, Xizeng [1 ]
Yan, Aimin [1 ]
Liu, Hong [2 ,3 ]
机构
[1] Univ Alabama Birmingham, Dept Radiol, Birmingham, AL 35233 USA
[2] Univ Oklahoma, Ctr Bioengn, Norman, OK 73019 USA
[3] Univ Oklahoma, Sch Elect & Comp Engn, Norman, OK 73019 USA
关键词
X-ray phase contrast; phase retrieval; breast density; SYNCHROTRON-RADIATION; MAMMOGRAPHY; RETRIEVAL; IMAGES;
D O I
10.1118/1.4729838
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: The high breast density is one of the biggest risk factors for breast cancer. Identifying patient having persistent high breast density is important for breast cancer screening and prevention. In this work the authors propose for the first time an x-ray phase-shifts-based method of breast density measurement. Methods: When x ray traverses the breast, x ray gets not only its intensity attenuated but also its phase shifted. Studying the x-ray phase-shifts generated by the breast tissues, we derived a general formula for determining the volumetric breast density from the breast phase map. The volumetric breast density is reconstructed by retrieving the breast phase map from just a single phase-sensitive projection of the breast, through the use of an innovative phase retrieval method based on the phase-attenuation duality. In order to numerically validate this phase-shifts-based method for measuring the volumetric breast density, the authors performed computer simulations with a digitally simulated anthropomorphic breast phantom. Results: Using the proposed phase-shifts-based method, we reconstructed the breast phantom's volumetric breast density, which differs from the phantom's intrinsic breast density by only 0.06%. In the presence of noises in the projection image, the reconstructed volumetric breast density differs from the phantom's intrinsic breast density by only 1.79% for a projection signal-to-noise-ratio (SNR) of 34. The error in reconstructed breast density is further reduced to 1.61% and 1.55% for SNR = 68 and SNR = 134, respectively, achieving good accuracies in the breast density determination. Conclusions: The authors proposed an x-ray phase-shifts-based method of measuring the volumetric breast density. The simulation results numerically validated the proposed method as a novel method of breast density measurement with good accuracies. 2012 American Association of Physicists in Medicine. [http://dx.doi.org/10.1118/1.4729838]
引用
收藏
页码:4239 / 4244
页数:6
相关论文
共 50 条
  • [31] Polychromatic X-ray effects on fringe phase shifts in grating interferometry
    Yan, Aimin
    Wu, Xizeng
    Liu, Hong
    OPTICS EXPRESS, 2017, 25 (06): : 6053 - 6068
  • [32] Phase-contrast X-ray imaging of breast
    Keyrilainen, Jani
    Bravin, Alberto
    Fernandez, Manuel
    Tenhunen, Mikko
    Virkkunen, Pekka
    Suortti, Pekka
    ACTA RADIOLOGICA, 2010, 51 (08) : 866 - 884
  • [33] X-ray tube spectral measurement method for quantitative analysis of X-ray fluorescence analysis
    Sasaki, Nobuharu
    Okada, Kennji
    Kawai, Jun
    X-RAY SPECTROMETRY, 2010, 39 (05) : 328 - 331
  • [34] Volumetric Measurement of Residual Stress Using High Energy X-Ray Diffraction
    Whitesell, R.
    McKenna, A.
    Wendt, S.
    Gray, J.
    42ND ANNUAL REVIEW OF PROGRESS IN QUANTITATIVE NONDESTRUCTIVE EVALUATION: INCORPORATING THE 6TH EUROPEAN-AMERICAN WORKSHOP ON RELIABILITY OF NDE, 2016, 1706
  • [35] ON THE ELECTRON DENSITY OF ATOMS IN THE X-RAY FOURIER METHOD
    ATOJI, M
    ACTA CRYSTALLOGRAPHICA, 1957, 10 (12): : 747 - 748
  • [36] SCATTER AND DENSITY-MEASUREMENT IN ONLINE X-RAY ANALYSIS
    SMITH, HW
    CIM BULLETIN, 1977, 70 (788): : 101 - 102
  • [37] Density measurement by a high energy X-ray CT system
    Kanamori, T
    TRENDS IN NDE SCIENCE AND TECHNOLOGY - PROCEEDINGS OF THE 14TH WORLD CONFERENCE ON NDT (14TH WCNDT), VOLS 1-5, 1996, : 1415 - 1418
  • [38] New X-ray density measurement technique with high sensitivity
    Chengdu University of Technology, Chengdu 610059, China
    Hedianzixue Yu Tance Jishue, 2007, 5 (954-957): : 954 - 957
  • [39] CALIBRATION OF X-RAY DENSITOMETRY FOR THE MEASUREMENT OF CORAL SKELETAL DENSITY
    CHALKER, B
    BARNES, D
    ISDALE, P
    CORAL REEFS, 1985, 4 (02) : 95 - 100
  • [40] X-RAY DUAL-PHOTON ABSORPTIOMETRY - A NEW METHOD FOR THE MEASUREMENT OF BONE-DENSITY
    CULLUM, ID
    ELL, PJ
    RYDER, JP
    BRITISH JOURNAL OF RADIOLOGY, 1989, 62 (739): : 587 - 592