Calibration procedure of a microwave total-power radiometer

被引:9
|
作者
Al-Ansari, K [1 ]
Garcia, P [1 ]
Riera, JM [1 ]
Benarroch, A [1 ]
Fernandez, D [1 ]
Fernandez, L [1 ]
机构
[1] Univ Politecn Madrid, ETSI Telecomunicac, Madrid, Spain
关键词
millimeter wave propagation; radiometer calibration; radiometry;
D O I
10.1109/7260.989862
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A total-power radiometer built in combination with a beacon receiver is being used for low-level attenuation measurements. This experimental receiver was built to measure atmospheric propagation impairments, using the ITALSAT satellite 50-GHz signal. The radiometer is mainly used to provide the reference level for the beacon measurements. Its precision should be better than 3 K, for low attenuation levels, in order to have 0.1-dB accuracy in the attenuation measurements. A suitable calibration procedure is described in this letter.
引用
收藏
页码:93 / 95
页数:3
相关论文
共 50 条
  • [1] FEASIBILITY STUDY OF TOTAL-POWER RADIOMETERS - CALIBRATION ACCURACY AND SENSITIVITY OF DIFFERENT RADIOMETER TYPES
    SKOU, N
    GUIJARRO, J
    ESA JOURNAL-EUROPEAN SPACE AGENCY, 1982, 6 (03): : 283 - 289
  • [2] A HIGH-RESOLUTION TOTAL-POWER RADIOMETER USING SAW COMPRESSIVE RECEIVERS
    CHAMBERS, JJ
    HUMPHRYES, RF
    SMITH, CI
    MICROWAVES & RF, 1983, 22 (05) : 104 - 104
  • [3] A HIGH-RESOLUTION TOTAL-POWER RADIOMETER USING SAW COMPRESSIVE RECEIVERS
    CHAMBERS, JJ
    HUMPHRYES, RF
    SMITH, CI
    MICROWAVE JOURNAL, 1983, 26 (05) : 75 - 75
  • [5] A broadband microwave total power radiometer
    Nakano, H
    Inoue, T
    Kawakami, T
    Kato, Y
    2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 451 - 452
  • [6] Low-cost millimeter-wave beacon receiver including total-power radiometer: Design, implementation and measurement calibration
    Riera, JM
    Al-Ansari, K
    Garcia, P
    Besada, JL
    IEEE ANTENNAS AND PROPAGATION MAGAZINE, 2002, 44 (01) : 45 - 54
  • [7] A multi-channel microwave radiometer uses reference averaging for calibration: Precision approaches that of a total power radiometer
    Racette, P
    Triesky, M
    Jones, D
    IGARSS '98 - 1998 INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, PROCEEDINGS VOLS 1-5: SENSING AND MANAGING THE ENVIRONMENT, 1998, : 1695 - 1697
  • [8] Unknown signal detection using a digital total-power radiometer with finite internal precision
    Koivu, S.
    Lehtomaki, J. J.
    Saarnisaari, H.
    Juntti, M.
    2006 IEEE INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE PROCEEDINGS, VOLS 1-5, 2006, : 1151 - +
  • [9] Impact of calibration on the performance of a total power radiometer
    Amiot, T.
    Goldstein, C.
    IGARSS: 2007 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-12: SENSING AND UNDERSTANDING OUR PLANET, 2007, : 4437 - 4440