Combined effect of injected interstitials and He implantation, and cavities inside dislocation loops in high purity Fe-Cr alloys

被引:13
|
作者
Bhattacharya, Arunodaya [1 ,3 ,4 ]
Meslin, Estelle [1 ]
Henry, Jean [2 ]
Lepretre, Frederic [5 ]
Decamps, Brigitte [3 ]
Barbu, Alain [1 ]
机构
[1] Univ Paris Saclay, Serv Rech Met Phys, CEA, DEN, F-91191 Gif Sur Yvette, France
[2] Univ Paris Saclay, Lab Anal Microstruct Mat, Serv Rech Met Appl, CEA,DEN, F-91191 Gif Sur Yvette, France
[3] Univ Paris Saday, CNRS, CSNSM, IN2P, Batiment 108, F-91405 Orsay, France
[4] Oak Ridge Natl Lab, Mat Sci & Technol Div, 1 Bethel Valley Rd, Oak Ridge, TN 37831 USA
[5] Univ Paris Sacla, Lab JANNuS, Serv Rech Met Phys, CEA,DEN, F-91191 Gif Sur Yvette, France
关键词
Fe-Cr alloys; Ion irradiation; Transmission electron microscopy (TEM); Void swelling; Chromium; ALPHA' PRECIPITATION; CHARGED-PARTICLE; STRUCTURAL-MATERIALS; EDGE DISLOCATIONS; FERRITIC STEELS; HIGH-FLUENCE; PURE IRON; IRRADIATION; HELIUM; DAMAGE;
D O I
10.1016/j.jnucmat.2019.03.043
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
High purity Fe-Cr alloys with Cr content ranging from 3 to 14 wt% were irradiated by self-ions at 500 degrees C in dual-beam mode up to 157 displacements per atom (dpa), 17 appm He/dpa. Transmission electron microscopy (TEM) on focused ion beam foils revealed the depth distribution of irradiation induced cavities and dislocation loops. A detailed quantitative analysis of cavity microstructure was performed on Fe14%Cr, while Fe(3, 5, 10, 12)%Cr were analysed qualitatively. A homogeneous distribution of small cavities were observed up to the damage peak. From surface to the damage peak, cavity number density increased almost linearly. The cavity microstructure changed drastically at and after the damage peak, where the size increased and number density decreased. Most notably, the microstructure consisted of a striking mixture of heterogeneously nucleated cavities inside dislocation loops and freely nucleated cavities in the matrix. Further, the depth-dependent void swelling increased continuously along the damage depth. This contrasts with most ion irradiation results where suppression of void swelling occurs adjacent to the damage peak due the injected interstitial effect. We hypothesize a plausible mechanism of the observed swelling variation based on a combined effect of the injected interstitials and helium implantation near the damage peak by comparing the results with those in pure iron irradiated under same conditions. This synergistic effect may develop cavity microstructures which do not necessarily reflect microstructures expected due to injected interstitial effect and can be easily wrongly interpreted. The depth dependent dislocation loop microstructure was studied qualitatively in Fe14%Cr sample. Up to the damage peak, a complex dense network of dislocations formed due to the interaction/impingement of the dislocation loops. Individually resolvable loops were only observed after the damage peak, where their association with cavities was noted. Helium also induced heterogeneous cavity nucleation on dislocations constituting a grain boundary and on pre-existing dislocation lines. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:30 / 44
页数:15
相关论文
共 44 条
  • [1] Chromium enrichment on the habit plane of dislocation loops in ion-irradiated high-purity Fe-Cr alloys
    Bhattacharya, A.
    Meslin, E.
    Henry, J.
    Pareige, C.
    Decamps, B.
    Genevois, C.
    Brimbal, D.
    Barbu, A.
    ACTA MATERIALIA, 2014, 78 : 394 - 403
  • [2] Cr segregation on dislocation loops enhances hardening in ferritic Fe-Cr alloys
    Terentyev, D.
    Bergner, F.
    Osetsky, Y.
    ACTA MATERIALIA, 2013, 61 (05) : 1444 - 1453
  • [3] Surface characterization for high purity Fe-Cr alloys
    Iwai, H
    Oiwa, R
    Takaki, S
    Abiko, K
    JOURNAL DE PHYSIQUE IV, 1995, 5 (C7): : 181 - 187
  • [4] Influence of injected interstitials on α′ precipitation in Fe-Cr alloys under self-ion irradiation
    Tissot, O.
    Pareige, C.
    Meslin, E.
    Decamps, B.
    Henry, J.
    MATERIALS RESEARCH LETTERS, 2017, 5 (02): : 117 - 123
  • [5] Confinement of motion of interstitial clusters and dislocation loops in BCC Fe-Cr alloys
    Terentyev, D.
    Klimenkov, M.
    Malerba, L.
    JOURNAL OF NUCLEAR MATERIALS, 2009, 393 (01) : 30 - 35
  • [6] Effect of Carbon on Dislocation Loops Formation during Self-Ion Irradiation in Fe-Cr Alloys at High Temperatures
    Shi, Tiantian
    Liu, Wenbo
    Su, Zhengxiong
    Yan, Xu
    Lu, Chenyang
    Yun, Di
    MATERIALS, 2022, 15 (06)
  • [7] Effect of chromium on void swelling in ion irradiated high purity Fe-Cr alloys
    Bhattacharya, A.
    Meslin, E.
    Henry, J.
    Barbu, A.
    Poissonnet, S.
    Decamps, B.
    ACTA MATERIALIA, 2016, 108 : 241 - 251
  • [8] EFFECT OF P IMPLANTATION ON THE CORROSION BEHAVIOR OF FE-CR ALLOYS
    SORENSEN, NR
    DIEGLE, RB
    PICRAUX, ST
    NELSON, GC
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 1987, 134 (8B) : C417 - C417
  • [9] EFFECT OF ION-IMPLANTATION ON THE HIGH-TEMPERATURE OXIDATION OF FE-CR ALLOYS
    KING, WE
    GRABOWSKI, KS
    JOURNAL OF METALS, 1988, 40 (07): : A38 - A38
  • [10] Dislocation loops in ultra-high purity Fe(Cr) alloys after 7.2 MeV proton irradiation
    Chen, J.
    Duval, F.
    Jung, P.
    Schaublin, R.
    Gao, N.
    Barthe, M. F.