Utility of the Pentax-AWS Airwayscope and Macintosh laryngoscope for airway management during chest compressions in 27A° left-lateral tilt: a manikin simulation study of maternal cardiopulmonary resuscitation
被引:12
|
作者:
Kohama, Hanako
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Div Intens Care, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Intens Care, Nishinomiya, Hyogo 6638501, Japan
Kohama, Hanako
[1
]
Komasawa, Nobuyasu
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Dept Anesthesiol, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Intens Care, Nishinomiya, Hyogo 6638501, Japan
Komasawa, Nobuyasu
[2
]
Ueki, Ryusuke
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Dept Anesthesiol, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Intens Care, Nishinomiya, Hyogo 6638501, Japan
Ueki, Ryusuke
[2
]
Yamamoto, Noriyasu
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Dept Regenerat Med, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Intens Care, Nishinomiya, Hyogo 6638501, Japan
Yamamoto, Noriyasu
[3
]
Tashiro, Chikara
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Dept Anesthesiol, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Intens Care, Nishinomiya, Hyogo 6638501, Japan
Tashiro, Chikara
[2
]
Kaminoh, Yoshiroh
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Dept Surg Ctr, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Intens Care, Nishinomiya, Hyogo 6638501, Japan
Kaminoh, Yoshiroh
[4
]
Nishi, Shin-ichi
论文数: 0引用数: 0
h-index: 0
机构:
Hyogo Coll Med, Div Intens Care, Nishinomiya, Hyogo 6638501, JapanHyogo Coll Med, Div Intens Care, Nishinomiya, Hyogo 6638501, Japan
Nishi, Shin-ichi
[1
]
机构:
[1] Hyogo Coll Med, Div Intens Care, Nishinomiya, Hyogo 6638501, Japan
[2] Hyogo Coll Med, Dept Anesthesiol, Nishinomiya, Hyogo 6638501, Japan
American Heart Association (AHA) 2010 cardiopulmonary resuscitation guidelines recommend high-quality chest compressions (minimum interruption, a pace > 100 compressions/min, and a depth more than 5 cm). They propose minor changes for pregnant women: manual left deviation of the uterus or a left-lateral incline of 27A degrees-30A degrees to alleviate pressure on the inferior vena cava. We examined the performance of the Pentax-AWS Airwayscope (AWS) and Macintosh laryngoscope (McL) for airway management during chest compressions on a 27A degrees left-lateral tilt (27 LLT) operating table. The study included 18 novice doctors in our anesthesia department. They performed tracheal intubation on a manikin positioned on a 27 LLT operating table using the AWS or McL with or without chest compressions. We measured the intubation time and success rate for tracheal intubation. Intubation success rate with the McL decreased with chest compressions compared to without chest compressions (12/18 vs. 18/18, P < 0.05). Intubation time with the McL was lengthened with chest compressions compared to without chest compressions (18.9 +/- A 4.0 s vs. 11.1 +/- A 1.0 s, P < 0.05). Intubation success rate was the same for the AWS with and without chest compressions (18/18 in both cases), and intubation time did not increase significantly without compressions compared to with compressions (11.6 +/- A 1.4 s vs. 12.6 +/- A 1.2 s, NS). The AWS is an effective tool for airway management during chest compressions in 27 LLT in a manikin, suggesting that the AWS may be a useful device for airway management during maternal resuscitation.