Balanced detection for spectral domain optical coherence tomography

被引:35
|
作者
Kuo, Wen-Chuan [1 ,2 ]
Lai, Chih-Ming [3 ]
Huang, Yi-Shiang [1 ]
Chang, Cheng-Yi [4 ]
Kuo, Yue-Ming [1 ]
机构
[1] Natl Yang Ming Univ, Inst Biophoton, Taipei 112, Taiwan
[2] Natl Yang Ming Univ, BMIRC, Taipei 112, Taiwan
[3] Ming Chuan Univ, Dept Elect Engn, Tao Yuan 333, Taiwan
[4] Natl Taiwan Normal Univ, Inst Electroopt Sci & Technol, Taipei 116, Taiwan
来源
OPTICS EXPRESS | 2013年 / 21卷 / 16期
关键词
NOISE; CAPILLAROSCOPY; REFLECTOMETRY; SENSITIVITY;
D O I
10.1364/OE.21.019280
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The use and advantages of applying balanced-detection (BD) operation method to high speed spectral domain optical coherence tomography (SDOCT) are presented in this study, which we believe is the first such demonstration. Compared to conventional SDOCT, BD-SDOCT provides two unique advantages. First, the method can suppress background noise and autocorrelation artifacts in biological tissues. Second, it is a power-efficient method which is particularly helpful for high speed SDOCT to eliminate random intensity noise and to achieve shot noise limited detection. This performance allows in vivo three-dimensional tissue visualization with high imaging quality and high speed. (c) 2013 Optical Society of America
引用
收藏
页码:19280 / 19291
页数:12
相关论文
共 50 条
  • [1] Adaptive balanced detection spectral domain optical coherence tomography
    Miller, David a.
    Kuranov, Roman
    Zhang, Hao F.
    BIOMEDICAL OPTICS EXPRESS, 2023, 14 (10) : 5208 - 5222
  • [2] Spectral Domain Optical Coherence Tomography with Dual-balanced Detection
    Bo, En
    Liu, Xinyu
    Chen, Si
    Luo, Yuemei
    Wang, Nanshuo
    Wang, Xianghong
    Liu, Linbo
    DESIGN AND QUALITY FOR BIOMEDICAL TECHNOLOGIES IX, 2016, 9700
  • [3] Polarization-based balanced detection for spectral-domain optical coherence tomography
    Black, Adam J.
    Akkin, Taner
    APPLIED OPTICS, 2015, 54 (24) : 7252 - 7257
  • [4] Balanced detection for spectral domain optical coherence tomography with fiber-based phase shifter
    Lee, Seung Seok
    Kim, Ju Ha
    Ma, Hye Jun
    Choi, Eun Seo
    OPTICAL FIBERS AND SENSORS FOR MEDICAL DIAGNOSTICS AND TREATMENT APPLICATIONS XVIII, 2018, 10488
  • [5] Balanced detection spectral-domain optical coherence tomography with a single line-scan camera
    Wan, Mingming
    Liang, Shanshan
    Li, Xinyu
    Duan, Zhengyu
    Zou, Jiebin
    Chen, Jun
    Yuan, Jin
    Zhang, Jun
    OPTICS EXPRESS, 2022, 30 (02) : 2578 - 2584
  • [6] Spectral-domain Optical Coherence Tomography for Material Detection
    Qin, Yu Wei
    Zhao, Hong
    MANUFACTURING ENGINEERING AND AUTOMATION II, PTS 1-3, 2012, 591-593 : 1139 - 1142
  • [7] Signal-to-Noise Ratio Enhanced Spectral Domain Optical Coherence Tomography with Dual-Balanced Detection
    Bo, En
    Liu, Xinyu
    Liu, Linbo
    INTERNATIONAL CONFERENCE ON MATERIALS FOR ADVANCED TECHNOLOGIES (ICMAT2015) - 4TH PHOTONICS GLOBAL CONFERENCE 2015, 2016, 140 : 140 - 143
  • [8] Spectral domain optical coherence tomography with balanced detection using single line-scan camera and optical delay line
    Hyeon, Min Gyu
    Kim, Hyung-Jin
    Kim, Beop-Min
    Eom, Tae Joong
    OPTICS EXPRESS, 2015, 23 (18): : 23079 - 23091
  • [9] Spectral calibration in spectral domain optical coherence tomography
    王凯
    丁志华
    Chinese Optics Letters, 2008, 6 (12) : 902 - 904
  • [10] Spectral calibration in spectral domain optical coherence tomography
    Wang, Kai
    Ding, Zhihua
    CHINESE OPTICS LETTERS, 2008, 6 (12) : 902 - 904