Flow-Through Quantification of Microplastics Using Impedance Spectroscopy

被引:54
|
作者
Colson, Beckett C. [1 ,2 ,3 ,4 ]
Michel, Anna P. M. [1 ]
机构
[1] Woods Hole Oceanog Inst, Dept Appl Ocean Phys & Engn, Woods Hole, MA 02543 USA
[2] MIT, Dept Mech Engn, Cambridge, MA 02139 USA
[3] MIT WHOI Joint Program Oceanog Appl Ocean Sci & E, Cambridge, MA USA
[4] MIT WHOI Joint Program Oceanog Appl Ocean Sci & E, Woods Hole, MA USA
关键词
microplastics; plastics; impedance spectroscopy; dielectric properties; instrumentation; particle detection; flow-through; environmental sensing;
D O I
10.1021/acssensors.0c02223
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Understanding the sources, impacts, and fate of microplastics in the environment is critical for assessing the potential risks of these anthropogenic particles. However, our ability to quantify and identify microplastics in aquatic ecosystems is limited by the lack of rapid techniques that do not require visual sorting or preprocessing. Here, we demonstrate the use of impedance spectroscopy for high-throughput flow-through microplastic quantification, with the goal of rapid measurement of microplastic concentration and size. Impedance spectroscopy characterizes the electrical properties of individual particles directly in the flow of water, allowing for simultaneous sizing and material identification. To demonstrate the technique, spike and recovery experiments were conducted in tap water with 212-1000 mu m polyethylene beads in six size ranges and a variety of similarly sized biological materials. Microplastics were reliably detected, sized, and differentiated from biological materials via their electrical properties at an average flow rate of 103 +/- 8 mL/min. The recovery rate was >= 90% for microplastics in the 300-1000 mu m size range, and the false positive rate for the misidentification of the biological material as plastic was 1%. Impedance spectroscopy allowed for the identification of microplastics directly in water without visual sorting or filtration, demonstrating its use for flow-through sensing.
引用
收藏
页码:238 / 244
页数:7
相关论文
共 50 条
  • [1] A Flow-through Passive Sampler for Microplastics in Air
    Dong, Huike
    Wang, Xiaoping
    Xu, Li
    Ding, Jiannan
    Wania, Frank
    ENVIRONMENTAL SCIENCE & TECHNOLOGY, 2023, 57 (06) : 2362 - 2370
  • [2] Assessment of Biofilm Growth on Microplastics in Freshwaters Using a Passive Flow-Through System
    Jiang, Chengyang
    Almuhtaram, Husein
    McKie, Michael J.
    Andrews, Robert C.
    TOXICS, 2023, 11 (12)
  • [3] CHARACTERIZATION OF FLOW-THROUGH ELECTRODE PROCESSES BY AC IMPEDANCE
    YUH, CY
    SELMAN, JR
    AICHE JOURNAL, 1993, 39 (04) : 636 - 646
  • [4] A DUAL FUEL-CELL FOR FLOW-THROUGH QUANTIFICATION OF MICROORGANISMS
    MIYABAYASHI, A
    DANIELSSON, B
    MATTIASSON, B
    ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 501 : 555 - 557
  • [5] Enhancing the aging of polystyrene microplastics through a flow-through electrochemical membrane system: Mechanism of confinement effect
    Li, Cong
    Shi, Lixia
    Ding, Jing
    Zhao, Qingliang
    Dong, Keke
    Liu, Tao
    Zhang, Yunshu
    JOURNAL OF HAZARDOUS MATERIALS, 2025, 488
  • [6] Selective on-site detection and quantification of polystyrene microplastics in water using fluorescence-tagged peptides and electrochemical impedance spectroscopy
    Motalebizadeh, Abbas
    Fardindoost, Somayeh
    Hoorfar, Mina
    JOURNAL OF HAZARDOUS MATERIALS, 2024, 480
  • [7] In situ infrared aerosol spectroscopy for a variety of nerve agent simulants using flow-through photoacoustics
    Gurton, Kristan P.
    Felton, Melvin
    Dahmani, Rachid
    Ligon, David
    APPLIED OPTICS, 2007, 46 (25) : 6323 - 6329
  • [8] FLOW-THROUGH ENTHALPIMETRY
    BERGE, H
    LAMMERT, R
    ZEITSCHRIFT FUR CHEMIE, 1987, 27 (09): : 319 - 323
  • [9] Flow-Through Assemblies
    Lstiburek, Joseph W.
    ASHRAE JOURNAL, 2015, 57 (12) : 46 - 51
  • [10] Impedance spectroscopy quantifies microplastics waste in waterways
    Boris Dyatkin
    MRS Bulletin, 2021, 46 : 305 - 305