Carcinoembryonic antigen as a biomarker for meconium-stained amniotic fluid

被引:0
|
作者
Mor, Amir [1 ]
Tal, Reshef [1 ]
Irani, Mohamad [1 ]
McCalla, Sandra [1 ]
Haberman, Shoshana [1 ]
Garg, Deepika [1 ]
Wajntraub, Birgitta [2 ]
机构
[1] Maimonides Hosp, Dept Obstet & Gynecol, 4802 10th Ave, Brooklyn, NY 11219 USA
[2] Laniado Med Ctr, Dept Obstet & Gynecol, Netanya, Israel
关键词
Carcinoembryonic antigen; Cutoff; Detection; Meconium-stained amniotic fluid; Rupture of membranes; PREGNANCY;
D O I
10.1016/j.ijgo.2015.07.032
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Objective: To assess whether elevated carcinoembryonic antigen (CEA) concentration in amniotic fluid can indicate meconium-stained amniotic fluid (MSAF). Methods: In a prospective cohort study, women with a term singleton pregnancy who were in labor but had intact membranes were recruited at a center in Israel over a 5-month period in 2013. Only women who subsequently underwent artificial rupture of membranes following a clear medical indication were included. Samples of amniotic fluid, urine, and serum were collected. Amniotic fluid was examined by sight and classified as clear, MSAF, or undetermined. CEA concentration in the samples was measured. Results: Among 81 participants, 45 had clear amniotic fluid, 28 had MSAF, and eight had undetermined amniotic fluid. Mean CEA concentration was more than 10 times higher in MSAF (2658 mu g/L, standard error 250) than in clear amniotic fluid (238 mu g/L, standard error 29; P < 0.001). Receiver operating characteristic curve analysis demonstrated a sensitivity of 96% and a specificity of 100% for distinguishing MSAF from clear amniotic fluid at a CEA cutoff of 799.2 mu g/L. CEA concentrations in urine and serum were all within the normal range (<= 5 mu g/L), irrespective of amniotic fluid status. Conclusion: High CEA concentrations in amniotic fluid can assist in the diagnosis of MSAF. These findings could provide the basis for a bedside test to detect MSAF following rupture of membranes. (C) 2015 International Federation of Gynecology and Obstetrics. Published by Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:329 / 331
页数:3
相关论文
共 50 条
  • [1] Can Carcinoembryonic Antigen Serve as an Indicator for Meconium-Stained Amniotic Fluid?
    Mor, Amir
    McCalla, Sandra
    Glick, Joseph
    Mamet, Jacob
    Wajntraub, Birgitta
    OBSTETRICS AND GYNECOLOGY, 2014, 123 : 72S - 72S
  • [2] Meconium-stained amniotic fluid
    Gallo, Dahiana M.
    Romero, Roberto
    Bosco, Mariachiara
    Gotsch, Francesca
    Jaiman, Sunil
    Jung, Eunjung
    Suksai, Manaphat
    Cajal, Carlos Lopez Ramon y
    Yoon, Bo Hyun
    Chaiworapongsa, Tinnakorn
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2023, 228 (05) : S1158 - S1178
  • [3] Meconium-stained amniotic fluid (MSF)
    Connolly, TP
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 191 (06) : 2175 - 2176
  • [4] Management of meconium-stained amniotic fluid
    Wiswell, TE
    Fuloria, M
    CLINICS IN PERINATOLOGY, 1999, 26 (03) : 659 - +
  • [5] Meconium-stained amniotic fluid (MSF) - Reply
    Molina, G
    Holguin, E
    Teran, E
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 2004, 191 (06) : 2176 - 2177
  • [6] Delivery of a Newborn With Meconium-Stained Amniotic Fluid
    Moxley, Michael D.
    OBSTETRICS AND GYNECOLOGY, 2017, 129 (03): : E33 - E34
  • [7] Managing patients with meconium-stained amniotic fluid
    Ash, AK
    HOSPITAL MEDICINE, 2000, 61 (12): : 844 - 848
  • [8] Meconium-stained amniotic fluid and the meconium aspiration syndrome - An update
    Cleary, GM
    Wiswell, TE
    PEDIATRIC CLINICS OF NORTH AMERICA, 1998, 45 (03) : 511 - +
  • [9] ULTRASOUND DIAGNOSIS OF MECONIUM-STAINED AMNIOTIC-FLUID
    BENACERRAF, BR
    GATTER, MA
    GINSBURGH, F
    AMERICAN JOURNAL OF OBSTETRICS AND GYNECOLOGY, 1984, 149 (05) : 570 - 572
  • [10] Significance of meconium-stained amniotic fluid in preterm deliveries
    Ivanova, Staribratova D.
    VIRCHOWS ARCHIV, 2009, 455 : 155 - 155