Quantification of tremor and bradykinesia in Parkinson's disease using a novel ambulatory monitoring system

被引:279
|
作者
Salarian, Arash
Russmann, Heike
Wider, Christian
Burkhard, Pierre R.
Vingerhoets, Francios J. G.
Aminian, Kamiar [1 ]
机构
[1] Swiss Fed Inst Technol, EPFL, Lab Movement Anal & Measurement, CH-1015 Lausanne, Switzerland
[2] CHU Vaudois, Dept Neurol, CH-1005 Lausanne, Switzerland
[3] Univ Hosp Geneva, Movement Disorders Clin, Dept Neurol, CH-1211 Geneva, Switzerland
[4] CHU Vaudois, Neurodegenerat Disorders Unit, CH-1005 Lausanne, Switzerland
关键词
biomedical signal processing; bradykinesia; gyroscope; Parkinson's disease; tremor; wearable technology;
D O I
10.1109/TBME.2006.886670
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
An ambulatory system for quantification of tremor and bradykinesia in patients with Parkinson's disease (PD) is presented. To record movements of the upper extremities, a sensing units which included miniature gyroscopes, has been fixed to each of the forearms. An algorithm to detect and quantify tremor and another algorithm to quantify bradykinesia have been proposed and validated. Two clinical studies have been performed. In the first study, 10 PD patients and 10 control subjects participated in a 45-min protocol of 17 typical daily activities. The algorithm for tremor detection showed an overall sensitivity of 99.5% and a specificity of 94.2% in comparison to a video reference. The estimated tremor amplitude showed a high correlation to the Unified Parkinson's Disease Rating Scale (UPDRS) tremor subscore (e.g., r = 0.87, p < 0.001 for the roll axis). There was a high and significant correlation between the estimated bradykinesia related parameters estimated for the whole period of measurement and respective UPDRS subscore (e.g., r = -0.83, p < 0.001 for the roll axis). In the second study, movements of upper extremities of 11 PD patients were recorded for periods of 3-5 hr. The patients were moving freely during the measurements. The effects of selection of window size used to calculate tremor and bradykinesia related parameters on the correlation between UPDRS and these parameters were studied. By selecting a window similar to the period of the first study, similar correlations were obtained. Moreover, one of the bradykinesia related parameters showed significant correlation (r = -0.74, p < 0.01) to UPDRS with window sizes as short as 5 min. Our study provides evidence that objective, accurate and simultaneous assessment of tremor and bradykinesia can be achieved in free moving PD patients during their daily activities.
引用
收藏
页码:313 / 322
页数:10
相关论文
共 50 条
  • [1] An ambulatory system to quantify bradykinesia and tremor in Parkinson's disease
    Salarian, A
    Russmann, H
    Vingerhoets, FJG
    Burkhard, PR
    Blanc, Y
    Dehollain, C
    ITAB 2003: 4TH INTERNATIONAL IEEE EMBS SPECIAL TOPIC CONFERENCE ON INFORMATION TECHNOLOGY APPLICATIONS IN BIOMEDICINE, CONFERENCE PROCEEDINGS: NEW SOLUTIONS FOR NEW CHALLENGES, 2003, : 35 - 38
  • [2] Objective monitoring of tremor and bradykinesia during DBS surgery for Parkinson disease
    Papapetropoulos, S.
    Jagid, J. R.
    Sengun, C.
    Singer, C.
    Gallo, B. V.
    NEUROLOGY, 2008, 70 (15) : 1244 - 1249
  • [3] Measurement of bradykinesia and chorea in Huntington's Disease using ambulatory monitoring
    Kotschet, Katya
    Osborn, Sarah
    Horne, Malcolm
    CLINICAL PARKINSONISM & RELATED DISORDERS, 2023, 8
  • [4] The metabolic substrates of bradykinesia and tremor in uncomplicated Parkinson's disease
    Lozza, C
    Marié, RM
    Baron, JC
    NEUROIMAGE, 2002, 17 (02) : 688 - 699
  • [5] Quantification of upper limb bradykinesia in Parkinson's disease
    Verhagen, L
    Fan, WQ
    Myre, B
    Dansen, M
    Kartha, N
    Arzbaecher, J
    NEUROLOGY, 2004, 62 (07) : A208 - A208
  • [6] A System for Finger Tremor Quantification in Patients with Parkinson's Disease
    Bravo, M.
    Bermeo, A.
    Huerta, M.
    Llumiguano, C.
    Bermeo, J.
    Clotet, R.
    Soto, A.
    2017 39TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2017, : 3549 - 3552
  • [7] An Ambulatory Tremor Score for Parkinson's Disease
    Braybrook, Michelle
    O'Connor, Sam
    Churchward, Philip
    Perera, Thushara
    Farzanehfar, Parisa
    Horne, Malcolm
    JOURNAL OF PARKINSONS DISEASE, 2016, 6 (04) : 723 - 731
  • [8] 24-hour ambulatory monitoring of limb tremor in Parkinson's Disease
    Smeja, M
    Foerster, F
    Fuchs, G
    Fahrenberg, J
    JOURNAL OF PSYCHOPHYSIOLOGY, 1998, 12 (04) : 397 - 397
  • [9] Standardized Handwriting to Assess Bradykinesia, Micrographia and Tremor in Parkinson's Disease
    Smits, Esther J.
    Tolonen, Antti J.
    Cluitmans, Luc
    van Gils, Mark
    Conway, Bernard A.
    Zietsma, Rutger C.
    Leenders, Klaus L.
    Maurits, Natasha M.
    PLOS ONE, 2014, 9 (05):
  • [10] Automatic detection and quantification of hand movements toward development of an objective assessment of tremor and bradykinesia in Parkinson's disease
    Pang, Yan
    Christenson, Jake
    Jiang, Feng
    Lei, Tim
    Rhoades, Remy
    Kern, Drew
    Thompson, John A.
    Liu, Chao
    JOURNAL OF NEUROSCIENCE METHODS, 2020, 333