Effect of the Enhancement Threshold on the Computer-Aided Detection of Breast Cancer using MRI

被引:18
|
作者
Levman, Jacob E. D. [1 ]
Causer, Petrina [1 ]
Warner, Ellen [1 ]
Martel, Anne L. [1 ]
机构
[1] Univ Toronto, Sunnybrook Res Inst, Dept Med Biophys, Toronto, ON M4N 3M5, Canada
关键词
Breast imaging; computer-aided detection; enhancement threshold; magnetic resonance imaging; CONTRALATERAL BREAST; NEOADJUVANT CHEMOTHERAPY; DISCRIMINATING BENIGN; MALIGNANT LESIONS; CLASSIFICATION; IMAGES; MAMMOGRAPHY; SYSTEM; CAD;
D O I
10.1016/j.acra.2009.03.018
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Rationale and Objectives. To evaluate the effect that variations in the enhancement threshold have on the diagnostic accuracy of two computer-aided detection (CAD) systems for magnetic resonance based breast cancer screening. Materials and Methods. Informed consent was obtained from all patients participating in cancer screening and this study was approved by the participating institution's review board. This retrospective study was nested in a prospective, single-institution, high-risk, breast screening study involving dynamic contrast-enhanced magnetic resonance imaging. Only those screening examinations (n = 223) for which a histopathological diagnosis was available were included. Two CAD methods were performed: the signal enhancement ratio (SER) and support vector machines (SVMs). Statistical analysis was performed by tracking changes in each CAD test's diagnostic accuracy (eg, receiver-operating characteristic [ROC] curve area, maximum possible sensitivity) with changes in the enhancement threshold. Results. The enhancement threshold plays a significant role in affecting a CAD test's potential sensitivity, ROC curve area, and number of assumed true and false-positive predictions per cancerous examination. A high threshold can also limit the CAD-based detection of the full size of a lesion. Conclusions. Enhancement thresholds can limit a CAD test's ability to diagnose a lesion's full size and as such should not be raised above 60%. The clinically used SER method exhibits a high rate of false positives at low enhancement thresholds and as such the threshold should not be set lower than 50%. The SVM method yielded better results in our study than the SER method at clinically realistic enhancement thresholds.
引用
收藏
页码:1064 / 1069
页数:6
相关论文
共 50 条
  • [1] A novel threshold-independent computer-aided detection algorithm for breast MRI
    Hatsiopoulou, O.
    Kubassova, O.
    Jolley, I.
    Ingram, C.
    BREAST CANCER RESEARCH, 2010, 12
  • [2] A novel threshold-independent computer-aided detection algorithm for breast MRI
    O Hatsiopoulou
    O Kubassova
    I Jolley
    C Ingram
    Breast Cancer Research, 12
  • [3] Computer-aided detection of breast cancer
    Milne, NC
    RADIOLOGY, 2004, 233 (02) : 615 - 616
  • [4] Computer-aided detection of breast cancer
    不详
    EUROPEAN JOURNAL OF CANCER, 2008, 44 (17) : 2536 - 2536
  • [5] Preoperative tumor size measurement in breast cancer patients: which threshold is appropriate on computer-aided detection for breast MRI?
    Sung Eun Song
    Bo Kyoung Seo
    Kyu Ran Cho
    Ok Hee Woo
    Eun Kyung Park
    Jaehyung Cha
    Seungju Han
    Cancer Imaging, 20
  • [6] Preoperative tumor size measurement in breast cancer patients: which threshold is appropriate on computer-aided detection for breast MRI?
    Song, Sung Eun
    Seo, Bo Kyoung
    Cho, Kyu Ran
    Woo, Ok Hee
    Park, Eun Kyung
    Cha, Jaehyung
    Han, Seungju
    CANCER IMAGING, 2020, 20 (01)
  • [7] Computer-Aided Breast Cancer Detection Using Mammograms: A Review
    El Atlas, Nadia
    El Aroussi, Mohammed
    Wahbi, Mohammed
    2014 SECOND WORLD CONFERENCE ON COMPLEX SYSTEMS (WCCS), 2014, : 626 - 631
  • [8] Computer-aided detection and diagnosis of breast cancer
    Collins, Michael J.
    Hoffmeister, Jeffrey
    Worrell, Steven W.
    SEMINARS IN ULTRASOUND CT AND MRI, 2006, 27 (04) : 351 - 355
  • [9] Computer-aided detection and diagnosis of breast cancer
    Vyborny, CJ
    Giger, ML
    Nishikawa, RM
    RADIOLOGIC CLINICS OF NORTH AMERICA, 2000, 38 (04) : 725 - +
  • [10] Computer-aided detection of breast cancer - Respond
    Helvie, MA
    RADIOLOGY, 2004, 233 (02) : 617 - 617