Numerical study of buoyant flows in street canyon caused by ground and building heating

被引:11
|
作者
Battista, Gabriele [1 ]
Mauri, Luca [1 ]
机构
[1] Univ Roma TRE, Dept Engn, Via Vasca Navale 79, I-00146 Rome, Italy
关键词
Urban Heat Island; CFD; Thermo-fluid dynamic effects; Building; Street canyon; ENERGY PERFORMANCE; CFD; VENTILATION; IMPACT;
D O I
10.1016/j.egypro.2016.11.129
中图分类号
O414.1 [热力学];
学科分类号
摘要
The urban areas discomfort is related to the increase of local temperatures, which is induced by the large concentration of the built environment, road pavement and the high construction materials thermal capacitance. The particular configuration of buildings arrangement amplifies the population vulnerability and the exposure to pollution. These conditions can be related to the "urban fabric" density, road geometrical characteristics, buildings features and, finally, to the lack of wide-open spaces. An important part of the heat exchange between buildings and the ambient surrounding is due to convective and radiative phenomena. Computational fluid dynamics (CFD) is often used to predict flow structures in urban areas for the determination of pollutant dispersion, human comfort or heat fluxes. During daytime building fa ades and ground surfaces are heated by solar radiation and thereby they induce buoyancy, which changes the flow field around buildings significantly. A computational fluid dynamics (CFD) model is developed and used to investigate the thermo-fluid dynamic effects inside and above a street canyon. In this study different simulations have been performed and validated, investigating the micro-climatic condition, such as thermal and air velocity fields. (C) 2016 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY-NC-ND license.
引用
收藏
页码:1018 / 1025
页数:8
相关论文
共 50 条
  • [1] Numerical simulation of street canyon flows with simple building geometries
    Xia, JY
    Hussaini, MY
    Leung, DYC
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2005, 131 (07): : 1099 - 1105
  • [2] Urban street-canyon flows with bottom heating
    Kim, JJ
    Baik, JJ
    ATMOSPHERIC ENVIRONMENT, 2001, 35 (20) : 3395 - 3404
  • [3] Characteristics of air exchange in a street canyon with ground heating
    Xie, Xiaomin
    Liu, Chun-Ho
    Leung, Dennis Y. C.
    Leung, Michael K. H.
    ATMOSPHERIC ENVIRONMENT, 2006, 40 (33) : 6396 - 6409
  • [4] Effect of Building Orientations on Gaseous Dispersion in Street Canyon: a Numerical Study
    Mohamed F. Yassin
    Mohamed A. Kassem
    Environmental Modeling & Assessment, 2014, 19 : 335 - 344
  • [5] Effect of Building Orientations on Gaseous Dispersion in Street Canyon: a Numerical Study
    Yassin, Mohamed F.
    Kassem, Mohamed A.
    ENVIRONMENTAL MODELING & ASSESSMENT, 2014, 19 (04) : 335 - 344
  • [6] The impact of building configuration and wall heating on pollutant dispersion in urban street canyon
    Hu Wei
    Zhong Qin
    2010 4TH INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING (ICBBE 2010), 2010,
  • [7] Numerical study on flow over buildings in street canyon
    Xia, JY
    Leung, DYC
    JOURNAL OF ENVIRONMENTAL ENGINEERING-ASCE, 2001, 127 (04): : 369 - 376
  • [8] Numerical study of buoyant flows in straight and converging chimneys
    Chandrashekar, Sriram
    Mugundhan, Vivek
    Velamati, Ratna Kishore
    INTERNATIONAL COMMUNICATIONS IN HEAT AND MASS TRANSFER, 2022, 136
  • [9] Wall heating effect modelling for street canyon environment prediction: Experimental and numerical investigation
    Li, Shitong
    Han, Jialong
    Liu, Tianxiang
    Wang, Jiaqi
    Tan, Zijing
    BUILDING AND ENVIRONMENT, 2025, 276
  • [10] A wind tunnel study on three-dimensional buoyant flows in street canyons with different roof shapes and building lengths
    Allegrini, Jonas
    BUILDING AND ENVIRONMENT, 2018, 143 : 71 - 88