Combined coronary artery bypass grafting and aortic valve replacement with minimal extracorporeal closed circuit circulation versus standard cardiopulmonary bypass

被引:24
|
作者
Yilmaz, Alaadin [1 ]
Sjatskig, Jelena [1 ]
van Boven, Wim J. [1 ]
Waanders, Frans G. [2 ]
Kelder, Johannes C. [3 ]
Sonker, Uday [1 ]
Kloppenburg, Geoffrey T. L. [1 ]
机构
[1] St Antonius Hosp, Dept Cardiothorac Surg, NL-3430 EM Nieuwegein, Netherlands
[2] St Antonius Hosp, Dept Clin Perfus, NL-3430 EM Nieuwegein, Netherlands
[3] St Antonius Hosp, Dept Cardiol, NL-3430 EM Nieuwegein, Netherlands
关键词
Aortic valve replacement; Minimal extracorporeal closed circuit; Coronary artery bypass grafting; INFLAMMATORY RESPONSE; SYSTEM;
D O I
10.1510/icvts.2010.241943
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Isolated aortic valve replacement (AVR) or coronary artery bypass grafting (CABG) using minimized extracorporeal circulation (MECC) has been shown to have less deleterious effects than standard cardiopulmonary bypass (CPB). In this prospective cohort study, we evaluated and compared clinical results of combined AVR with CABG using MECC. We prospectively collected preoperative, intraoperative, postoperative and follow-up data of 65 patients who underwent combined AVR with CABG using MECC and compared these with 135 patients undergoing combined AVR with CABG using standard CPB. No significant differences were seen in patients demographic characteristics or intraoperative data. Patients in the MECC group experienced a smaller preoperative haemoglobin drop (4.5 +/- 0.8 g/dl vs. 5.0 +/- 0.5 g/dl, P=0.002) resulting in higher haemoglobin at discharge (11.3 +/- 1.3 g/dl vs. 10.8 +/- 1.1 g/dl, P=0.03). They had decreased blood products requirements (P=0.004) compared to patients in the standard CPB group. No differences were noted in pulmonary complications, neurological events or mortality. We present for the first time data showing that combined AVR with CABG using MECC is feasible and provides better clinical results compared to standard CPB with regard to blood products requirements, without compromising operative morbidity or mortality. (C) 2010 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.
引用
收藏
页码:754 / 757
页数:4
相关论文
共 50 条
  • [1] Comparison of minimal invasive extracorporeal circulation versus standard cardiopulmonary bypass systems on coronary artery bypass surgery
    Ozgur, Mustafa Mert
    Aksut, Mehmet
    Ozer, Tanil
    Gurel, Baris
    Yerli, Ismail
    Simsek, Mine
    Sarikaya, Sabit
    Kirali, Kaan
    TURK GOGUS KALP DAMAR CERRAHISI DERGISI-TURKISH JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2024, 32 (02): : 141 - 150
  • [2] Aortic valve replacement with the minimal extracorporeal circulation (Jostra MECC System) versus standard cardiopulmonary bypass: A randomized prospective trial
    Remadi, JP
    Rakotoarivello, Z
    Marticho, P
    Trojette, F
    Benamar, A
    Poulain, H
    Tribouilloy, C
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 128 (03): : 436 - 441
  • [3] Evaluation of Closed Cardiopulmonary Bypass Circuit for Aortic Valve Replacement
    Kobayashi, Yasuhiko
    Mitsuno, Masataka
    Yamamura, Mitsuhiro
    Tanaka, Hiroe
    Ryomoto, Masaaki
    Fukui, Shinya
    Tsujiya, Noriko
    Kajiyama, Tetsuya
    Miyamoto, Yuji
    ASAIO JOURNAL, 2010, 56 (04) : 309 - 312
  • [4] Combined coronary artery bypass grafting with aortic valve replacement EHIRC experience
    R Bapna
    D Singh
    V Kohli
    ZS Meharwal
    Y Mishra
    S Bazaz
    S Collison
    N Trehan
    Indian Journal of Thoracic and Cardiovascular Surgery, 2006, 22 (1) : 60 - 60
  • [5] Coronary artery bypass grafting with minimal versus conventional extracorporeal circulation; an economic analysis
    Anastasiadis, K.
    Fragoulakis, V.
    Antonitsis, P.
    Maniadakis, N.
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 168 (06) : 5336 - 5343
  • [6] Economic analysis of coronary artery bypass grafting with minimal versus conventional extracorporeal circulation
    K Anastasiadis
    V Fragoulakis
    P Antonitsis
    N Maniadakis
    Journal of Cardiothoracic Surgery, 8 (Suppl 1)
  • [7] Minimally invasive closed circuit versus standard extracorporeal circulation for aortic valve replacement
    Castiglioni, Alessandro
    Verzini, Alessandro
    Pappalardo, Federico
    Colangelo, Nicola
    Torracca, Lucia
    Zangrillo, Alberto
    Alfieri, Ottavio
    ANNALS OF THORACIC SURGERY, 2007, 83 (02): : 586 - 591
  • [8] Effect of minimal extracorporeal circulation versus conventional extracorporeal circulation on postoperative outcome of coronary artery bypass grafting
    Srivastava P.K.
    Rajan S.D.
    Agrawal S.
    Radakrishnan S.
    Varghese T.
    Cherian K.M.
    Indian Journal of Thoracic and Cardiovascular Surgery, 2010, 26 (1) : 1 - 4
  • [9] Coronary artery bypass grafting surgery with minimal extracorporeal circulation system
    Alberto Lezama-Urtecho, Carlos
    de Leon-Lagunas, Edith
    Careaga-Reyna, Guillermo
    CIRUGIA Y CIRUJANOS, 2010, 78 (02): : 121 - 125
  • [10] Minimal extracorporeal circulation is a promising technique for coronary artery bypass grafting
    Immer, Franz F.
    Ackermann, Andreas
    Gygax, Erich
    Stalder, Mario
    Englberger, Lars
    Eckstein, Friedrich S.
    Tevaearai, Hendrik T.
    Schmidli, Juerg
    Carrel, Thierry P.
    ANNALS OF THORACIC SURGERY, 2007, 84 (05): : 1515 - 1521