In Vivo Validation of CAAS QCA-3D Coronary Reconstruction Using Fusion of Angiography and Intravascular Ultrasound (ANGUS)

被引:59
|
作者
Schuurbiers, Johan C. H.
Lopez, Nieves Gonzalo [2 ]
Ligthart, Jurgen [2 ]
Gijsen, Frank J. H.
Dijkstra, Jouke [3 ]
Serruys, Patrick W. [2 ]
Van der Steen, Antonius F. [4 ]
Wentzel, Jolanda J. [1 ,4 ]
机构
[1] ErasmusMC, Biomech Lab, NL-3000 CA Rotterdam, Netherlands
[2] ErasmusMC, Intervent Cardiol, Rotterdam, Netherlands
[3] Leiden Univ, Med Ctr, Dept Radiol, LKEB, Leiden, Netherlands
[4] Inter Cardiol Inst Netherlands, Utrecht, Netherlands
关键词
angiography; IVUS; 3D-reconstruction; validation; ENDOTHELIAL SHEAR-STRESS; SIROLIMUS-ELUTING STENTS; 3-DIMENSIONAL RECONSTRUCTION; IVUS ANGUS; ARTERIES; SYSTEM; ATHEROSCLEROSIS; IMPLANTATION; THICKNESS; LUMEN;
D O I
10.1002/ccd.21872
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives: The CAAS QCA-3D system (Pie Medical Imaging BV, the Netherlands) was validated against 3D reconstructions based on fusion of angiography and intravascular ultrasound (ANGUS), allowing slice by slice validation of the lumen areas and 3D geometric values. Background: Accurate online 3D reconstruction of human coronary arteries is of outmost importance during clinical practice in the catheterization laboratory. The CHAS QCA-3D system provides technology to 3D reconstruct human coronary arteries based on two or more angiographic images, but was not validated in realistic arteries before. Methods: Ten patients were imaged using biplane angiography and an ECG gated (TomTec) intravascular ultrasound (IVUS) pullback (stepsize 0.5 mm, Boston Scientific). The coronary arteries were 3D reconstructed based on (a) fusion of biplane angiography and IVUS (ANGUS) and (b) CAAS QCA-3D using the biplane angiography images. For both systems the length, the curvature and the lumen areas at 0.5 mm spacing were calculated and compared. Results: Bland-Altman analysis indicated that the CHAS QCA-3D system underestimated the lumen areas systematically by 0.45 +/- 1.49 mm 2. The segment length was slightly underestimated by the CAAS QCA-3D system (62.1 +/- 11.3 vs. 63.2 +/- 11.4 mm; P < 0.05), while the curvature of the analyzed segments were not statistically different. Conclusions: The CAAS QCA-3D system allows 3D reconstruction of human coronary arteries based on biplane angiography. Validation against the ANGUS system showed that both the 3D geometry and lumen areas are highly correlated which makes the CHAS QCA-3D system a promising tool for applications in the catheterization laboratory and opens possibilities for computational fluid dynamics. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:620 / 626
页数:7
相关论文
共 50 条
  • [1] In vivo validation of CAAS QCA-3D coronary reconstruction using fusion of angiography and intravascular ultrasound (ANGUS)
    Wentzel, J. J.
    Schuurbiers, J. C. H.
    Lopez, N. Gonzalo
    Gijsen, F. J. H.
    Dijkstra, J.
    Serruys, P. W.
    Van der Steen, A. F. W.
    EUROPEAN HEART JOURNAL, 2008, 29 : 849 - 849
  • [2] 3D Reconstruction of Coronary Arteries using Intravascular Ultrasound (IVUS) and Angiography
    Ma, Heather T.
    Wang, Huanli
    Wang, Caixia
    Hau, William Kongto
    2013 IEEE INTERNATIONAL CONFERENCE OF IEEE REGION 10 (TENCON), 2013,
  • [3] Validation Study of a 3D-QCA Coronary Reconstruction Method Using a Hybrid IntraVascular UltraSound and Angiography Reconstruction Method and Patient-Specific Fractional Flow Reserve Data
    Siogkas, Panagiotis K.
    Athanasiou, Lambros S.
    Sakellarios, Antonis I.
    Stefanou, Kostas A.
    Exarchos, Themis P.
    Papafaklis, Michail I.
    Naka, Katerina K.
    Parodi, O.
    Michalis, Lampros K.
    Fotiadis, Dimitrios I.
    2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2015, : 973 - 976
  • [4] Geometrically correct 3-D reconstruction of intravascular ultrasound images by fusion with biplane angiography - Methods and validation
    Wahle, A
    Prause, GPM
    DeJong, SC
    Sonka, M
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 1999, 18 (08) : 686 - 699
  • [5] A method for 3D reconstruction of coronary arteries using biplane angiography and intravascular ultrasound images
    Bourantas, CV
    Kourtis, IC
    Plissiti, ME
    Fotiadis, DI
    Katsouras, CS
    Papafaklis, MI
    Michalis, LK
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2005, 29 (08) : 597 - 606
  • [6] Accurate 3-D reconstruction of tortuous coronary vessels using biplane angiography and intravascular ultrasound
    Prause, GPM
    DeJong, SC
    McKay, CR
    Sonka, M
    PHYSIOLOGY AND FUNCTION FROM MULTIDIMENSIONAL IMAGES - MEDICAL IMAGING 1997, 1997, 3033 : 225 - 234
  • [7] Three-dimensional coronary artery reconstruction using fusion of intravascular ultrasound and biplane angiography
    Bourantas, C
    Fotiadis, DI
    Kourtis, IC
    Michalis, LK
    Plissiti, M
    CARS 2003: COMPUTER ASSISTED RADIOLOGY AND SURGERY, PROCEEDINGS, 2003, 1256 : 1133 - 1138
  • [8] A comprehensive method for geometrically correct 3-D reconstruction of coronary arteries by fusion of intravascular ultrasound and biplane angiography
    Wahle, A
    Prause, GPM
    DeJong, SC
    Sonka, M
    COMPUTER-AIDED DIAGNOSIS IN MEDICAL IMAGING, 1999, 1182 : 363 - 368
  • [9] 3D reconstruction of coronary artery bifurcations from intravascular ultrasound and angiography
    Wu, Wei
    Oguz, Usama M.
    Banga, Akshat
    Zhao, Shijia
    Thota, Anjani Kumar
    Gadamidi, Vinay Kumar
    Vasa, Charu Hasini
    Harmouch, Khaled M.
    Naser, Abdallah
    Tieliwaerdi, Xiarepati
    Chatzizisis, Yiannis S.
    SCIENTIFIC REPORTS, 2023, 13 (01):
  • [10] 3D reconstruction of coronary artery bifurcations from intravascular ultrasound and angiography
    Wei Wu
    Usama M. Oguz
    Akshat Banga
    Shijia Zhao
    Anjani Kumar Thota
    Vinay Kumar Gadamidi
    Charu Hasini Vasa
    Khaled M. Harmouch
    Abdallah Naser
    Xiarepati Tieliwaerdi
    Yiannis S. Chatzizisis
    Scientific Reports, 13 (1)