Factor Analysis of Dynamic Sequence with Spatial Prior for 2D Cardiac Spect Sequences Analysis

被引:1
|
作者
Filippi, Marc [1 ]
Desvignes, Michel [1 ]
Moisan, Eric [1 ]
Ghezzi, Catherine [1 ]
Perret, Pascale [1 ]
Fagret, Daniel [2 ]
机构
[1] Univ Grenoble Alpes, GIPSA LAB, St Martin Dheres, France
[2] Univ Grenoble Alpes, INSERM1039, St Martin Dheres, France
关键词
Source separation; SPECT; Factor Analysis; Spatial priors; Penalized least squares; SEPARATION; FAMIS;
D O I
10.1007/978-3-319-48680-2_21
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Unmixing is often a necessary step to analyze 2D SPECT image sequence. However, factor analysis of dynamic sequences (FADS), the commonly used method for unmixing SPECT sequences, suffers from non-uniqueness issue. Optimization-based methods were developed to overcome this issue. These methods are effective but need improvement when the mixing is important or with very low SNR. In this paper, a new objective function using soft spatial prior knowledge is developed. Comparison with previous methods, efficiency and robustness to the choice of priors are illustrated with tests on synthetic dataset. Results on 2D SPECT sequences with high level of noise are also presented and compared.
引用
收藏
页码:228 / 237
页数:10
相关论文
共 50 条
  • [1] Factor analysis with a priori knowledge -: application in dynamic cardiac SPECT
    Sitek, A
    Di Bella, EVR
    Gullberg, GT
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (09): : 2619 - 2638
  • [2] Extraction of the input function in cardiac dynamic SPECT using factor analysis.
    DiBella, EVR
    Gullberg, GT
    JOURNAL OF NUCLEAR MEDICINE, 1997, 38 (05) : 23 - 23
  • [3] Cardiac image analysis from 2D sequences based on nonlinear diffusion and curve evolution
    Liu, X
    Shou, W
    Shu, XH
    ELECTRONIC IMAGING AND MULTIMEDIA TECHNOLOGY III, 2002, 4925 : 295 - 300
  • [4] Spatial Dynamic Factor Analysis
    Lopes, Hedibert Freitas
    Salazar, Esther
    Gamerman, Dani
    BAYESIAN ANALYSIS, 2008, 3 (04): : 759 - 792
  • [5] VARIOWIN: software for spatial data analysis in 2D
    Bohling, G
    COMPUTERS & GEOSCIENCES, 2001, 27 (01) : 125 - 127
  • [6] An improved factor analysis method for cardiac dynamic SPECT studies by using a priori information
    Sitek, A
    DiBella, EVR
    Gullberg, GT
    1999 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1999, : 1014 - 1016
  • [7] Variation Theorems for Dynamic Analysis of 2D Structures
    Kaveh, Ali
    Najimi, Meisam
    INTERNATIONAL JOURNAL OF CIVIL ENGINEERING, 2008, 6 (03) : 216 - 225
  • [8] STATIC AND DYNAMIC ANALYSIS OF A 2D MEMS MICROMIRROR
    Imam, Hasan Tareq
    Ma, Yuan
    2010 23RD CANADIAN CONFERENCE ON ELECTRICAL AND COMPUTER ENGINEERING (CCECE), 2010,
  • [9] Model-Based Factor Analysis of Dynamic Sequences of Cardiac Positron Emission Tomography
    Klein, R.
    Beanlands, R. S.
    Adler, A.
    deKemp, R.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4464 - +
  • [10] Filters in 2D and 3D Cardiac SPECT Image Processing
    Lyra, Maria
    Ploussi, Agapi
    Rouchota, Maritina
    Synefia, Stella
    CARDIOLOGY RESEARCH AND PRACTICE, 2014, 2014