Automatic flow system titration based on multicommutation for spectrophotometric determination of total acidity in silage extracts

被引:0
|
作者
Tumang, CA
Paim, APS
Reis, BF
机构
[1] Univ Sao Paulo, Ctr Energia Nucl Agr, BR-13400970 Sao Paulo, Brazil
[2] Univ Sao Paulo, Inst Quim Sao Carlos, BR-13566590 Sao Carlos, SP, Brazil
关键词
D O I
暂无
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A multicommutated flow titration procedure is proposed for the spectrophotometric determination of total acidity in silage extracts. The flow network comprises a set of 3-way solenoid valves, computer-controlled to provide facilities to handle the titrand, titrant, and carrier solutions by using a single pumping channel. The procedure is based on the volumetric fraction variation approach that maintains the same volume of titrand solution and varies the titrant solution step by step, to provide determination without the use of an analytical curve. The procedure is implemented by using phenolphthalein as an external indicator; the proposed algorithm was able to titrate silage extracts presenting different color intensities. Sample solutions with concentrations ranging from 10(-3) to 10(-1) mol/L total acidity could be analyzed by using 10(-2) mol/L sodium hydroxide as the titrant solution. Other advantages include a relative standard deviation of <1.0% (n = 4) for a typical silage extract solution containing 26 mmol/L total acidity; an analytical throughput of 16 determinations per hour was also achieved. Accuracy was assessed by processing a set of silage extract solutions and comparing the results with those obtained by using the conventional potentiometric titration procedure. No significant difference at the 95% confidence level was observed.
引用
收藏
页码:328 / 332
页数:5
相关论文
共 50 条
  • [1] A Monosegmented Flow Titration for the Spectrophotometric Determination of Total Acidity in Vinegar
    Ricardo S. Honorato
    Mário C. U. Araújo
    Germano Veras
    Elias A. G. Zagatto
    Rui A. S. Lapa
    José L. F. C. Lima
    Analytical Sciences, 1999, 15 : 665 - 668
  • [2] A monosegmented flow titration for the spectrophotometric determination of total acidity in vinegar
    Honorato, RS
    Araújo, MCU
    Veras, G
    Zagatto, EAG
    Lapa, RAS
    Lima, JLFC
    ANALYTICAL SCIENCES, 1999, 15 (07) : 665 - 668
  • [3] Automatic multicommutation flow system for wide range spectrophotometric calcium determination
    Rocha, FRP
    Martelli, PB
    Frizzarin, RM
    Reis, BF
    ANALYTICA CHIMICA ACTA, 1998, 366 (1-3) : 45 - 53
  • [4] Multicommutation flow system for spectrophotometric L(+)lactate determination in silage material using an enzymatic reaction
    Tumang, CA
    Borges, EP
    Reis, BF
    ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) : 59 - 65
  • [5] AUTOMATIC PROCEDURE FOR SPECTROPHOTOMETRIC DETERMINATION OF HYDROQUINONE EMPLOYING MULTICOMMUTATION FLOW IN ANALYSIS SYSTEM.
    de Aquino Lima, Manoel de Jesus
    Castilho, Quesia Guedes da Silva
    Fernandes, Ridvan Nunes
    Tanaka, Auro Atsushi
    dos Reis, Boaventura Freire
    QUIMICA NOVA, 2016, 39 (05): : 592 - 597
  • [6] An automatic system for acidity determination based on sequential injection titration and the monosegmented flow approach
    Kozak, Joanna
    Wojtowicz, Marzena
    Gawenda, Nadzieja
    Koscielniak, Pawel
    TALANTA, 2011, 84 (05) : 1379 - 1383
  • [7] An improved flow system for spectrophotometric determination of anions exploiting multicommutation and multidetection
    Rocha, FRP
    Martelli, PB
    Reis, BF
    ANALYTICA CHIMICA ACTA, 2001, 438 (1-2) : 11 - 19
  • [8] Spectrophotometric Determination of Thiocyanate in Human Saliva Employing Micropumping Multicommutation Flow System
    Silva Junior, Joilton J.
    Farias, Marcelo A.
    Silva, Valdinete L.
    Montenegro, Maria C. B. S. M.
    Araujo, Alberto N.
    Lavorante, Andre F.
    Paim, Ana Paula S.
    SPECTROSCOPY LETTERS, 2010, 43 (03) : 213 - 219
  • [9] Automatic spectrophotometric procedure for the determination of tartaric acid in wine employing multicommutation flow analysis process
    Fernandes, EN
    Reis, BF
    ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) : 380 - 386
  • [10] Monosegmented flow system exploiting multicommutation applied to spectrophotometric determination of manganese in soybean digests
    Smiderle, M
    Reis, BF
    Rocha, FRP
    ANALYTICA CHIMICA ACTA, 1999, 386 (1-2) : 129 - 135