Electric field induced second harmonic (E-FISH) generation for characterization of fast ionization wave discharges at moderate and low pressures

被引:54
|
作者
Chng, T. L. [1 ]
Orel, I. S. [1 ]
Starikovskaia, S. M. [1 ]
Adamovich, I., V [2 ]
机构
[1] Univ Paris Sud, CNRS, Lab Plasma Phys, Ecole Polytech,Sorbonne Univ,Observ Paris,Inst Po, Route Saclay, F-91128 Palaiseau, France
[2] Ohio State Univ, Dept Mech & Aerosp Engn, Nonequilibrium Thermodynam Labs, Columbus, OH 43210 USA
来源
PLASMA SOURCES SCIENCE & TECHNOLOGY | 2019年 / 28卷 / 04期
关键词
second harmonic generation; E-FISH; nanosecond plasma; fast ionization wave; HIGH OVERVOLTAGE; MIXTURES; IGNITION; SUSCEPTIBILITY; BREAKDOWN; PULSE; AIR;
D O I
10.1088/1361-6595/ab0b22
中图分类号
O35 [流体力学]; O53 [等离子体物理学];
学科分类号
070204 ; 080103 ; 080704 ;
摘要
The electric field in an ionization wave discharge in nitrogen at 20-100 mbar, initiated by positive polarity, high-voltage, ns duration pulses, is measured by ps second harmonic generation. The axial electric field component is determined both during the propagation of the ionization wave along the discharge tube, and after the wave reaches the grounded electrode, spanning the entire discharge gap. The temporal resolution of the present measurements is 200 ps, with the spatial resolution in the axial direction of approximately 0.5 mm. The second harmonic signal exhibits a quadratic dependence on the Laplacian electric field but indicates that in this pressure range most of the signal is generated within the wall of the tube. Absolute calibration of the signal is obtained from the current shunt data, after the ionization wave has reached the grounded electrode. Comparison of the data taken at different pressures shows that the peak value of the axial electric field in the wave front, 8-11 kV cm(-1), has a fairly weak dependence on pressure, with the peak reduced electric field reaching approximate to 2000 Td at 20 mbar. Reducing the pressure from 100 to 20 mbar, while keeping the discharge pulse voltage waveform the same, steepens the ionization wave front considerably, from 3.0 to 1.0 ns full width at half maximum. The results demonstrate that ps second harmonic generation may be employed for electric field measurements in low-pressure discharges, discharges sustained in small diameter capillary tubes, and discharges sustained in gas mixtures with low nonlinear susceptibility, at the conditions when the detection of the signal generated directly in the plasma is challenging. High temporal resolution of the present measurements indicates a possibility of detection of non-local electron kinetics effects induced by a rapidly varying, high peak value electric field in low and moderate pressure ionization wave discharges.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] Temporal electric field of a helium plasma jet by electric field induced second harmonic (E-FISH) method
    LI, Xu
    Jin, Shaohui
    Song, Ke
    Nie, Lanlan
    Liu, Dawei
    Lu, Xinpei
    PLASMA SCIENCE & TECHNOLOGY, 2023, 25 (01)
  • [2] Temporal electric field of a helium plasma jet by electric field induced second harmonic(E-FISH) method
    李旭
    晋绍珲
    宋珂
    聂兰兰
    刘大伟
    卢新培
    Plasma Science and Technology, 2023, 25 (01) : 50 - 59
  • [3] Temporal electric field of a helium plasma jet by electric field induced second harmonic(E-FISH) method
    李旭
    晋绍珲
    宋珂
    聂兰兰
    刘大伟
    卢新培
    Plasma Science and Technology, 2023, (01) : 50 - 59
  • [4] Spatiotemporally resolved measurements of electric field around a piezoelectric transformer using electric-field induced second harmonic (E-FISH) generation
    Yang, Jinyu
    Barnat, Edward, V
    Im, Seong-kyun
    Go, David B.
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 2022, 55 (22)
  • [5] Suppression of coherent interference to electric-field-induced second-harmonic (E-FISH) signals for the measurement of electric field in mesoscale confined geometries
    Vorenkamp, Madeline
    Steinmetz, Scott A.
    Chen, Timothy Y.
    Ju, Yiguang
    Kliewer, Christopher J.
    OPTICS LETTERS, 2023, 48 (07) : 1930 - 1933
  • [6] Effect of the electric field profile on the accuracy of E-FISH measurements in ionization waves
    Chng, Tat Loon
    Pai, David Z.
    Guaitella, Olivier
    Starikovskaia, Svetlana M.
    Bourdon, Anne
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2022, 31 (01):
  • [7] Simulation of ionization-wave discharges: a direct comparison between the fluid model and E-FISH measurements
    Zhu, Yifei
    Chen, Xiancong
    Wu, Yun
    Hao, Jinbo
    Ma, Xiaoguang
    Lu, Pengfei
    Tardiveau, Pierre
    PLASMA SOURCES SCIENCE & TECHNOLOGY, 2021, 30 (07):
  • [8] Electric Field Measurement in Dielectric Barrier Discharges Using Electric Field Induced Second Harmonic Generation in Ambient Air
    Cui, Yingzhe
    Wang, Hao
    Zhuang, Chijie
    Luo, Haiyun
    Wang, Xinxin
    Zeng, Rong
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2020, 27 (06) : 2071 - 2077
  • [9] Electric field measurements under DC corona discharges in ambient air by electric field induced second harmonic generation
    Cui, Yingzhe
    Zhuang, Chijie
    Zeng, Rong
    APPLIED PHYSICS LETTERS, 2019, 115 (24)
  • [10] Electric field induced second harmonic generation with and without fringes
    Meshulam, G
    Berkovic, G
    Kotler, Z
    Sa'ar, A
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2000, 71 (09): : 3490 - 3493