Role of Transesophageal Echocardiography in the Diagnosis of Paradoxical Low Flow, Low Gradient Severe Aortic Stenosis
被引:2
|
作者:
Abudiab, Muaz M.
论文数: 0引用数: 0
h-index: 0
机构:
Mayo Clin, Dept Internal Med, Div Cardiovasc Dis, 13400 E Shea Blvd, Scottsdale, AZ 85259 USAMayo Clin, Dept Internal Med, Div Cardiovasc Dis, 13400 E Shea Blvd, Scottsdale, AZ 85259 USA
Abudiab, Muaz M.
[1
]
Pandit, Anil
论文数: 0引用数: 0
h-index: 0
机构:
Mayo Clin, Dept Internal Med, Div Cardiovasc Dis, 13400 E Shea Blvd, Scottsdale, AZ 85259 USAMayo Clin, Dept Internal Med, Div Cardiovasc Dis, 13400 E Shea Blvd, Scottsdale, AZ 85259 USA
Pandit, Anil
[1
]
Chaliki, Hari P.
论文数: 0引用数: 0
h-index: 0
机构:
Mayo Clin, Dept Internal Med, Div Cardiovasc Dis, 13400 E Shea Blvd, Scottsdale, AZ 85259 USAMayo Clin, Dept Internal Med, Div Cardiovasc Dis, 13400 E Shea Blvd, Scottsdale, AZ 85259 USA
Chaliki, Hari P.
[1
]
机构:
[1] Mayo Clin, Dept Internal Med, Div Cardiovasc Dis, 13400 E Shea Blvd, Scottsdale, AZ 85259 USA
Background and Objectives: Prior studies indicate that up to 35% of cases of severe aortic stenosis (AS) have paradoxical low flow, low gradient despite preserved left ventricular ejection fraction (LVEF). However, error in left ventricular outflow tract (LVOT) diameter may lead to misclassification. Herein, we determined whether measurement of LVOT diameter by transesophageal echocardiography (TEE) results in reclassification of cases to non-severe AS. Subjects and Methods: Patients with severe AS with aortic valve area (AVA) <1 cm(2) by transthoracic echocardiography (TTE) within 6 months were studied. Paradoxical low flow, low gradient was defined as mean Doppler gradient (MG) <40 mm Hg and stroke volume index (SVI) <= 35 mL/m(2). Preserved LVEF was defined as >= 0.50. Results: Among 108 patients, 12 (15%) had paradoxical low flow, low gradient severe AS despite preserved LVEF based on TTE measurement. When LVOT diameter by TEE in 2D was used, only 5 (6.3%) patients had low flow, low gradient severe AS (p<0.001). Coefficients of variability for intraobserver and interobserver measurement of LVOT were <10%. However, the limits of agreement between TTE and TEE measurement of LVOT ranged from 0.43 cm (950/o confidence interval [CI]: 0.36 to 0.5) to-0.31 cm (95% CI:-0.38 to -0.23). Conclusion: TEE measured LVOT diameter may result in reclassification to moderate AS in some patients due to low prevalence of true paradoxical low flow, low gradient (PLFLG) severe AS.
机构:
Univ A Coruna, Complejo Hosp Univ A Coruna, CIBER CV A Coruna, Cardiol, La Coruna, SpainUniv A Coruna, Complejo Hosp Univ A Coruna, CIBER CV A Coruna, Cardiol, La Coruna, Spain
Peteiro Vazquez, J. C.
Bouzas-Mosquera, A.
论文数: 0引用数: 0
h-index: 0
机构:
Univ A Coruna, Complejo Hosp Univ A Coruna, CIBER CV A Coruna, Cardiol, La Coruna, SpainUniv A Coruna, Complejo Hosp Univ A Coruna, CIBER CV A Coruna, Cardiol, La Coruna, Spain
Bouzas-Mosquera, A.
Vazquez-Rodriguez, J. M.
论文数: 0引用数: 0
h-index: 0
机构:
Univ A Coruna, Complejo Hosp Univ A Coruna, CIBER CV A Coruna, Cardiol, La Coruna, SpainUniv A Coruna, Complejo Hosp Univ A Coruna, CIBER CV A Coruna, Cardiol, La Coruna, Spain
机构:
Ctr Privado Cardiol, Rivadavia 550 T4000NIL, San Miguel De Tucuman, ArgentinaCtr Privado Cardiol, Rivadavia 550 T4000NIL, San Miguel De Tucuman, Argentina
Prado, Aldo
Hasbani, Eduardo
论文数: 0引用数: 0
h-index: 0
机构:
Ctr Privado Cardiol, Rivadavia 550 T4000NIL, San Miguel De Tucuman, ArgentinaCtr Privado Cardiol, Rivadavia 550 T4000NIL, San Miguel De Tucuman, Argentina
Hasbani, Eduardo
Stoermann, Walter
论文数: 0引用数: 0
h-index: 0
机构:
Clin El Castano, San Juan, PR, ArgentinaCtr Privado Cardiol, Rivadavia 550 T4000NIL, San Miguel De Tucuman, Argentina
Stoermann, Walter
REVISTA DE LA FEDERACION ARGENTINA DE CARDIOLOGIA,
2012,
41
(01):
: 13
-
16