Fast and accurate calibration of 1D and 2D gratings

被引:6
|
作者
Lei, Lihua [1 ]
Liu, Yi [1 ]
Chen, Xin [2 ]
Fu, Yunxia [1 ]
Li, Yuan [1 ]
机构
[1] Shanghai Inst Measurement & Testing Technol, 1500 Zhangheng Rd, Shanghai 201203, Peoples R China
[2] Shanghai Jiao Tong Univ, Dept Instrument Sci & Engn, Shanghai 200240, Peoples R China
关键词
2D gratings; cosine error; fast scan direction; standard; calibration; TRACEABLE CALIBRATION;
D O I
10.4028/www.scientific.net/AMR.317-319.2196
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Grating is a widely-used standard to calibrate the horizontal plane of almost all kinds of microscopes. A grating standard consisting of 1D grating and 2D grating was designed and fabricated by Shanghai Institute of Measurement and Testing Technology (SIMT). In this paper, a metrological large-range nano measuring machine integrated with atomic force microscope (AFM) and laser focus sensor (LFS) is used to calibrate this standard. In order to guarantee the measurement accuracy, cosine error, a significant error source which is caused by deviation angle between the scan direction and the perpendicular direction of the grating line, is analysed. Therefore, the scan direction should be determined accurately. For 1D grating, the scan direction is determined by two scanning profiles with deflection angle. Different beginning directions and deflection angles are analyzed to find the best beginning direction and deflection angle for fast and accurate scan direction determination. For 2D grating, the application of the same scan direction determination procedure is extended by using beginning direction and deflection angle which is opposite for 1D grating. Mean pitch is calculated through another profile which is scanned along the calculated scanning direction. Data from different probes are evaluated and the results demonstrate the method well.
引用
收藏
页码:2196 / +
页数:2
相关论文
共 50 条
  • [1] Method of fabrication of 1D and 2D gratings
    Stepanov, DY
    Surve, SR
    Balon, SAP
    LASER BEAM CONTROL AND APPLICATIONS, 2006, 6101
  • [2] Electrically Controlled 1D and 2D Cholesteric Liquid Crystal Gratings
    Hamdi, R.
    Petriashvili, G.
    De Santo, M. P.
    Lombardo, G.
    Barberi, R.
    MOLECULAR CRYSTALS AND LIQUID CRYSTALS, 2012, 553 : 97 - 102
  • [3] Calibration of a 1D/1D urban flood model using 1D/2D model results in the absence of field data
    Leandro, J.
    Djordjevic, S.
    Chen, A. S.
    Savic, D. A.
    Stanic, M.
    WATER SCIENCE AND TECHNOLOGY, 2011, 64 (05) : 1016 - 1024
  • [4] Fast Recursive Equalizers for 1D and 2D Linear Equalization
    Drost, Robert J.
    Singer, Andrew C.
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2012, 60 (07) : 3886 - 3891
  • [5] Calibration of 1D and 2D Fluvial Models with a Metamodel Based Optimization
    Benefice, Guillaume
    Duron, Luc
    Villanueva, Amaya
    Yang, Rui
    ADVANCES IN HYDROINFORMATICS: MODELS FOR COMPLEX AND GLOBAL WATER ISSUES-PRACTICES AND EXPECTATIONS, 2022, : 773 - 794
  • [6] Laser fabrication of 1D and 2D periodic subwavelength gratings on titanium films
    Ibrahim, Qosai
    Andreeva, Yaroslava
    Suvorov, Alexander
    Khmelenin, Dmitry
    Grigoryev, Evgeniy
    Shcherbakov, Alexey A.
    Sinev, Dmitry
    OPTICS AND LASER TECHNOLOGY, 2024, 174
  • [7] Coherent atom optics with fast metastable beams: Metastable helium diffraction by 1D and 2D magnetized reflection gratings
    Grucker, J.
    Baudon, J.
    Karam, J. -C.
    Perales, F.
    Bocvarski, V.
    Ducloy, M.
    SIX INTERNATIONAL CONFERENCE OF THE BALKAN PHYSICAL UNION, 2007, 899 : 34 - +
  • [8] Robust Calibration Procedure of a Manipulator and a 2D Laser Scanner using a 1D Calibration Target
    Alberts, Jan
    Kleinschmidt, Sebastian P.
    Wagner, Bernardo
    ICINCO: PROCEEDINGS OF THE 16TH INTERNATIONAL CONFERENCE ON INFORMATICS IN CONTROL, AUTOMATION AND ROBOTICS, VOL 1, 2019, : 112 - 119
  • [9] Scaling calibration in region of interest reconstruction with the 1D and 2D ATRACT algorithm
    Xia, Yan
    Dennerlein, Frank
    Bauer, Sebastian
    Hofmann, Hannes
    Hornegger, Joachim
    Maier, Andreas
    INTERNATIONAL JOURNAL OF COMPUTER ASSISTED RADIOLOGY AND SURGERY, 2014, 9 (03) : 345 - 356
  • [10] Scaling calibration in region of interest reconstruction with the 1D and 2D ATRACT algorithm
    Yan Xia
    Frank Dennerlein
    Sebastian Bauer
    Hannes Hofmann
    Joachim Hornegger
    Andreas Maier