Highly balanced gradiometer systems based on HTS-SQUIDs for the use in magnetically unshielded environment

被引:6
|
作者
Borgmann, J
Rijpma, AP
ter Brake, HJM
Rogalla, H
David, P
机构
[1] Univ Twente, Fac Appl Phys, Low Temp Div, NL-7500 AE Enschede, Netherlands
[2] Univ Bonn, Inst Strahlen & Kernphys, D-53117 Bonn, Germany
关键词
D O I
10.1109/77.783827
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Two different concepts for gradiometer formation were tested applying high-temperature rf SQUIDs operated at 77 K in liquid nitrogen. All gradiometer systems are fully based on magnetometers. The first concept applies a compensating magnetometer at different positions to actively cancel the magnetic field at the location of other magnetometers. These magnetometers were arranged In an axial direction. In parts, a system of superconducting plates was used to align the relative magnetic orientation of the magnetometers. The outputs of these sensors were used to form a highly balanced electronic gradiometer. The second concept Is based on electronic noise cancellation. A set of three magnetometers arranged in an axial direction was used to form an electronic second-order gradiometer. Different types of reference systems based on HTS-SQUID magnetometers and fluxgate sensors were applied to the gradiometer signal for achieving a high common mode rejection of the environmental disturbances. The performance of the different systems is demonstrated in a magnetically unshielded environment as well as in a shielded environment and the common mode rejection of homogeneous magnetic fields is measured. To demonstrate the performance of the systems, biomagnetic measurements have been performed in shielded and unshielded environments.
引用
收藏
页码:3680 / 3683
页数:4
相关论文
共 31 条
  • [1] HTS dc squids for eddy current NDE in an unshielded environment
    Carr, C
    Romans, EJ
    Macfarlane, JC
    Pegrum, CM
    Donaldson, GB
    APPLIED SUPERCONDUCTIVITY, 1997, 5 (7-12) : 373 - 378
  • [2] Integrated LTS gradiometer SQUIDs for measurements of magnetic field distributions in an unshielded environment
    Stolz, R
    Schultze, V
    Zakosarenko, VM
    Fritzsch, L
    Meyer, HG
    CZECHOSLOVAK JOURNAL OF PHYSICS, 1996, 46 : 2769 - 2770
  • [3] Electronic gradiometry for NDE in an unshielded environment with stationary and moving HTS SQUIDs
    Carr, C
    Cochran, A
    Kuznik, J
    McKirdy, DM
    Donaldson, GB
    CRYOGENICS, 1996, 36 (09) : 691 - 695
  • [4] A HTS SQUID gradiometer using superconducting coplanar resonators for operation in unshielded environment
    Zhang, Y
    Panaitov, G
    Wang, SG
    Wolters, N
    Otto, R
    Schubert, J
    Zander, W
    Krause, HJ
    Bousack, H
    CHINESE JOURNAL OF PHYSICS, 2000, 38 (02) : 330 - 338
  • [5] HTS SQUID gradiometer using substrate resonators operating in an unshielded environment -: A portable MCG system
    Zhang, Y
    Wolters, N
    Schubert, E
    Lomparski, D
    Banzet, M
    Panaitov, G
    Krause, HJ
    Mück, M
    Braginski, AI
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) : 389 - 392
  • [6] Integrated LTS gradiometer SQUID systems for unshielded measurements in a disturbed environment
    Zakosarenko, V
    Warzemann, L
    Schambach, J
    Bluthner, K
    Berthel, KH
    Kirsch, G
    Weber, P
    Stolz, R
    SUPERCONDUCTOR SCIENCE & TECHNOLOGY, 1996, 9 (4A): : A112 - A115
  • [7] Long baseline hardware gradiometer based on HTS rf-SQUIDs with substrate resonators
    Panaitov, GI
    Zhang, Y
    Krause, HJ
    Schubert, E
    Banzet, M
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) : 841 - 844
  • [8] A high-Tc second-order gradiometer for use in an unshielded environment
    Broussov, PP
    Romans, EJ
    Carr, C
    Donaldson, GB
    Pegrum, CM
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2003, 13 (02) : 837 - 840
  • [9] GRADIOMETER FOR STUDY OF MAGNETIC-FIELDS GENERATED BY HUMAN HEART IN A MAGNETICALLY UNSHIELDED ENVIRONMENT - PRELIMINARY-RESULTS
    BARBANERA, S
    CARELLI, P
    MODENA, I
    ROMANI, GL
    JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1978, 11 (04): : 297 - 298
  • [10] Contactless measurement of corrosion currents at galvanic elements by means of HTS SQUID sensors in magnetically unshielded environment
    Menzel, K
    Krause, HJ
    Sawade, G
    MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2002, 53 (06): : 417 - 421