Comparative evaluation of Truview evo2 and Macintosh laryngoscope for ease of orotracheal intubation in children - A prospective randomized controlled trial

被引:3
|
作者
Pangasa, Neha [1 ,2 ]
Dali, Jaspal Singh [1 ]
Sharma, Kavita Rani [1 ]
Arya, Mona [1 ]
Pachisia, Anant Vikram [1 ,3 ]
机构
[1] Maulana Azad Med Coll MAMC & Associated Hosp, Dept Anaesthesiol & Intens Care, New Delhi, India
[2] All India Inst Med Sci, Dept Anaesthesiol Pain Med & Crit Care, New Delhi, India
[3] Asian Inst Med Sci, Dept Crit Care Med, Faridabad, Haryana, India
关键词
CL grade; Macintosh; time to intubation; Truview evo2;
D O I
10.4103/joacp.JOACP_118_18
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Background and Aims: Truview evo2 has been found to improve the glottic view when compared with the Miller blade in pediatric population. However, there is limited literature comparing it with Macintosh laryngoscope in children. We thus aimed to assess and compare Truview evo2 with the Macintosh laryngoscope for orotracheal intubation in children with regards to time to intubate, laryngoscopic view, ease of intubation, and associated hemodynamic changes. Material and Methods: Fifty ASA I-II children aged 2-8 years for elective surgery requiring general anesthesia with orotracheal intubation participated in this prospective randomized-controlled study. They were randomly allocated to two groups. In group-M (N = 25), laryngoscopy and intubation were performed using Macintosh laryngoscope, and in group-T (N = 25), Truview evo2 laryngoscope was used. Modified Cormack-Lehane grade, time to intubation, intubation difficulty score (IDS), and hemodynamic changes were compared between the groups. Data were analyzed using SPSS statistical software version 17 and P value <0.05 was considered statistically significant. Results: CL grade 1 was found in a larger number of patients of group-T (P = 0.003) and CL grades2a and 2b were found in a larger number of patients of group-M (P = 0.023 and P = 0.037, respectively). The mean time to intubation was significantly longer in group-T (19.0 +/- 3.4 seconds) than in group-M (13.1 +/- 2.1 seconds), P = 0.00. The over all IDS was lower in group-T than group M [i.e. median (IQR): 0 (0-0) vs 1 (0-2), respectively]. Heart rate, systolic and diastolic blood pressure, and oxygen saturation were comparable between the groups at all times. Conclusion: Truview evo2 provides better laryngeal view and has a lesser IDS, but takes longer for intubation, when compared to the Macintosh laryngoscope in children.
引用
收藏
页码:25 / 29
页数:5
相关论文
共 50 条
  • [1] Evaluation of Truview evo2 (R) Laryngoscope In Anticipated Difficult Intubation - A Comparison To Macintosh Laryngoscope
    Singh, Ishwar
    Khaund, Abhijit
    Gupta, Abhishek
    INDIAN JOURNAL OF ANAESTHESIA, 2009, 53 (02) : 164 - 168
  • [2] A comparison of the TruView EVO2 and macintosh laryngoscope blades
    Tutuncu, Ayse Cigdem
    Kaya, Guner
    Tunali, Yusuf
    Altintas, Fatis
    Dilmen, Ozlem Korkmaz
    CLINICS, 2011, 66 (04) : 709 - 711
  • [3] An evaluation of the TruView EVO2 laryngoscope
    Li, J. B.
    Xiong, Y. C.
    Wang, X. L.
    Fan, X. H.
    Li, Y.
    Xu, H.
    Ma, Y.
    Deng, X. M.
    ANAESTHESIA, 2007, 62 (09) : 940 - 943
  • [4] Evaluation of the Truview (TM) EVO2 laryngoscope for nasotracheal intubation
    Raveendra, U. S.
    Mehandale, Sripada G.
    Shetty, Sumalatha R.
    Kamath, Manjunath R.
    SAUDI JOURNAL OF ANAESTHESIA, 2012, 6 (04) : 398 - 402
  • [5] Truview EVO2 and Standard Macintosh Laryngoscope for Tracheal Intubation During Cardiopulmonary Resuscitation A Comparative Randomized Crossover Study
    Gaszynska, Ewelina
    Gaszynski, Tomasz
    MEDICINE, 2014, 93 (14)
  • [6] COMPARISON OF TRUVIEW EVO2 LARYNGOSCOPE WITH MACINTOSH LARYNGOSCOPE ON PATIENTS UNDERGOING CAESAREAN SECTION
    Inal, Mehmet Turan
    Memis, Dilek
    Yandim, Tarik
    Ersoz, Sule
    NOBEL MEDICUS, 2016, 12 (03): : 12 - 16
  • [7] Truview EVO2 Laryngoscope Reduces Intubation Difficulty in Maxillofacial Surgeries
    Shrestha, Shubhakalyan
    Arora, Suman
    Jain, Divya
    Rattan, Vidya
    Sharma, Rakesh Kumar
    JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2015, 73 (10) : 1919.e1 - 1919.e8
  • [8] ALTERNATIVE IN DIFFICULT INTUBATION: VIDEO-LARYNGOSCOPE TRUVIEW EVO2
    Redondo, F. J.
    Madrazo, M.
    Bosque, A.
    Pretel, M.
    REVISTA ESPANOLA DE ANESTESIOLOGIA Y REANIMACION, 2008, 55 (03): : 196 - 196
  • [9] Evaluation of new laryngoscope blade for tracheal intubation, Truview EVO2©:: a manikin study
    Miceli, L.
    Cecconi, M.
    Tripi, G.
    Zauli, M.
    Della Rocca, G.
    EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2008, 25 (06) : 446 - 449
  • [10] Training resident anesthesiologists in adult challenging intubation comparing Truview EVO2™ and Macintosh laryngoscope: a preliminary study
    Carlino, C.
    Pastore, J. C.
    Battistini, G. M.
    Cancellieri, F.
    De Caria, D.
    Ruggieri, N.
    Bordone, G.
    Bellato, V.
    MINERVA ANESTESIOLOGICA, 2009, 75 (10) : 563 - 567