W-band system-on-chip electron cyclotron emission imaging system on DIII-D

被引:21
|
作者
Zhu, Y. [1 ]
Yu, J-H [1 ]
Yu, G. [1 ]
Ye, Y. [1 ]
Tobias, B. [2 ]
Diallo, A. [3 ]
Kramer, G. [3 ]
Ren, Y. [3 ]
Domier, C. W. [1 ]
Li, X. [4 ]
Luo, C. [1 ]
Chen, M. [1 ]
Chen, Y. [1 ]
Luhmann, N. C., Jr. [1 ]
机构
[1] Univ Calif Davis, Davis, CA 95616 USA
[2] Los Alamos Natl Lab, Los Alamos, NM 87545 USA
[3] Princeton Plasma Phys Lab, POB 451, Princeton, NJ 08543 USA
[4] Univ Sci & Technol China, Hefei 230000, Anhui, Peoples R China
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2020年 / 91卷 / 09期
关键词
34;
D O I
10.1063/5.0018082
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Monolithic, millimeter-wave "system-on-chip" (SoC) technology has been employed in heterodyne receiver integrated circuit radiometers in a newly developed Electron Cyclotron Emission Imaging (ECEI) system on the DIII-D tokamak for 2D electron temperature profile and fluctuation evolution diagnostics. A prototype module operating in the E-band (72 GHz-80 GHz) was first employed in a 2 x 10 element array that demonstrated significant improvements over the previous quasi-optical Schottky diode mixer arrays during the 2018 operational campaign of the DIII-D tokamak. For compatibility with International Thermonuclear Experimental Reactor relevant scenarios on DIII-D, the SoC ECEI system was upgraded with 20 horn-waveguide receiver modules. Each individual module contains a University of California Davis designed W-band (75 GHz-110 GHz) receiver die that integrates a broadband low noise amplifier, a double balanced down-converting mixer, and a x4 multiplier on the local oscillator (LO) chain. A x2 multiplier and two IF amplifiers are packaged and selected to further boost the signal strength and downconvert the signal frequency. The upgraded W-band array exhibits >30 dB additional gain and 20x improvement in noise temperature compared with the previous Schottky diode radio frequency mixer input systems; an internal 8 times multiplier chain is used to bring down the LO frequency below 12 GHz, thereby obviating the need for a large aperture for quasi-optical LO coupling and replacing it with coaxial connectors. Horn-waveguide shielding housing avoids out-of-band noise interference on each individual module. The upgraded ECEI system plays an important role for absolute electron temperature evolution and fluctuation measurements for edge and core region transport physics studies.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] System-on-chip approach microwave imaging reflectometer on DIII-D tokamak
    Zhu, Y.
    Chen, Y.
    Yu, J. -h.
    Domier, C.
    Yu, G.
    Liu, X.
    Kramer, G.
    Ren, Y.
    Diallo, A.
    Luhmann, N. C.
    Li, X.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2022, 93 (11):
  • [2] DIII-D Electron Cyclotron Heating System and Experiments
    Gorelov, Y.
    Lohr, J.
    Ponce, D.
    Torrezan, A.
    Cengher, M.
    2017 42ND INTERNATIONAL CONFERENCE ON INFRARED, MILLIMETER, AND TERAHERTZ WAVES (IRMMW-THZ), 2017,
  • [3] W-Band Modular Antenna/Detector Array for the Electron Cyclotron Emission Imaging System in KSTAR
    Lee, Gwan Hui
    Lee, Jung Seok
    Kim, Dong Hwi
    Nashuha, Syifa Haunan
    Kim, Mun Ju
    Min, Byung Cheol
    Lee, Jae Hyun
    Lee, Woo Chang
    Yun, Gun Su
    Kim, Tae Gyu
    Kim, Bong Tae
    Choi, Hyun Chul
    Park, Hyeon Keo
    In, Yong Kyoon
    Kim, Kang Wook
    APPLIED SCIENCES-BASEL, 2022, 12 (05):
  • [4] Performance and Upgrades for the Electron Cyclotron Heating System on DIII-D
    Cengher, Mirela
    Lohr, J.
    Gorelov, Y. A.
    Ellis, R.
    Kolemen, Egemen
    Ponce, D.
    Noraky, S.
    Moeller, C. P.
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2014, 42 (07) : 1964 - 1970
  • [5] Electron Cyclotron Heating System Status and Upgrades on DIII-D
    Cengher, Mirela
    Lohr, John
    Gorelov, Yuri
    Prater, Ron
    Torrezan, Antonio
    Anderson, James
    Ponce, Dan
    Chen, Xi
    Moeller, Charles
    Ellis, Robert
    2015 IEEE 26TH SYMPOSIUM ON FUSION ENGINEERING (SOFE), 2015,
  • [6] DIII-D Electron Cyclotron Heating System Status and Upgrades
    Cengher, Mirela
    Lohr, John
    Gorelov, Yuri
    Torrezan, Antonio
    Ponce, Dan
    Chen, Xi
    Moeller, Charles
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2016, 44 (12) : 3465 - 3470
  • [7] The electron cyclotron resonant heating system on the DIII-D tokamak
    Lohr, J
    Gorelov, YA
    Kajiwara, K
    Ponce, D
    Callis, RW
    Doane, JL
    Ellis, RL
    Grunloh, HJ
    Moeller, CP
    Peavy, J
    Prater, R
    Tooker, JF
    FUSION SCIENCE AND TECHNOLOGY, 2005, 48 (02) : 1226 - 1237
  • [8] Electron cyclotron emission radiometer upgrade on the DIII-D tokamak
    Austin, ME
    Lohr, J
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (03): : 1457 - 1459
  • [9] Commissioning of electron cyclotron emission imaging instrument on the DIII-D tokamak and first data
    Tobias, B.
    Domier, C. W.
    Liang, T.
    Kong, X.
    Yu, L.
    Yun, G. S.
    Park, H. K.
    Classen, I. G. J.
    Boom, J. E.
    Donne, A. J. H.
    Munsat, T.
    Nazikian, R.
    Van Zeeland, M.
    Boivin, R. L.
    Luhmann, N. C., Jr.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (10):
  • [10] High level of integration of front-end imaging optics system for electron cyclotron emission imaging diagnostics on the DIII-D tokamak
    Li, X. L.
    Zhu, Y. L.
    Yu, G. Y.
    Cao, J. H.
    Xu, G. S.
    Luhmann, N. C.
    FUSION ENGINEERING AND DESIGN, 2021, 172