Distinguishing new science from calibration effects in the electron-volt neutron spectrometer VESUVIO at ISIS

被引:7
|
作者
Chatzidimitriou-Dreismann, C. A. [1 ]
Gray, E. MacA [2 ]
Blach, T. P. [2 ]
机构
[1] Tech Univ Berlin, Inst Chem Sekr C2, D-10623 Berlin, Germany
[2] Griffith Univ, Queensland Micro & Nanotechnol Ctr, Brisbane, Qld 4111, Australia
基金
澳大利亚研究理事会;
关键词
Neutron Compton scattering; Deep inelastic neutron scattering; Time-of-flight; Calibration; Attosecond physics; MOMENTUM DISTRIBUTIONS; COMPTON-SCATTERING; FLUID HYDROGEN; MOLECULES; DEUTERIUM;
D O I
10.1016/j.nima.2012.02.025
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The "standard" procedure for calibrating the Vesuvio eV neutron spectrometer at the ISIS neutron source, forming the basis for data analysis over at least the last decade, was recently documented in considerable detail by the instrument's scientists. Additionally, we recently derived analytic expressions of the sensitivity of recoil peak positions with respect to fight-path parameters and presented neutron-proton scattering results that together called into question the validity of the "standard" calibration. These investigations should contribute significantly to the assessment of the experimental results obtained with Vesuvio. Here we present new results of neutron-deuteron scattering from D-2 in the backscattering angular range (theta > 90 degrees) which are accompanied by a striking energy increase that violates the Impulse Approximation, thus leading unequivocally the following dilemma: (A) either the "standard" calibration is correct and then the experimental results represent a novel quantum dynamical effect of D which stands in blatant contradiction of conventional theoretical expectations; (B) or the present "standard" calibration procedure is seriously deficient and leads to artificial outcomes. For Case (A), we allude to the topic of attosecond quantum dynamical phenomena and our recent neutron scattering experiments from H-2 molecules. For Case (B), some suggestions as to how the "standard" calibration could be considerably improved are made. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:120 / 125
页数:6
相关论文
共 3 条
  • [1] The VESUVIO electron volt neutron spectrometer
    Mayers, J.
    Reiter, G.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2012, 23 (04)
  • [2] Calibration of the electron volt spectrometer, a deep inelastic neutron scattering spectrometer at the ISIS pulsed neutron spallation source
    Fielding, AL
    Mayers, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 480 (2-3): : 680 - 689
  • [3] Calibration of an electron volt neutron spectrometer
    Mayers, J.
    Adams, M. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 625 (01): : 47 - 56