Myometrial Invasion in Endometrial Cancer: Diagnostic Accuracy of Diffusion-weighted 3.0-T MR Imaging-Initial Experience

被引:141
|
作者
Lin, Gigin [2 ]
Ng, Koon-Kwan [2 ]
Chang, Chee-Jen [6 ]
Wang, Jiun-Jie [2 ]
Ho, Kung-Chu [3 ]
Yen, Tzu-Chen [3 ]
Wu, Tzu-I [1 ]
Wang, Chun-Chieh [5 ]
Chen, Yu-Ruei [2 ]
Huang, Yu-Ting [2 ]
Ng, Shu-Hang [2 ]
Jung, Shih-Ming [4 ]
Chang, Ting-Chang [1 ]
Lai, Chyong-Huey [1 ]
机构
[1] Chang Gung Mem Hosp, Linkou Med Ctr, Dept Obstet & Gynecol, Tao Yuan 333, Taiwan
[2] Chang Gung Mem Hosp, Linkou Med Ctr, Dept Radiol, Tao Yuan 333, Taiwan
[3] Chang Gung Mem Hosp, Linkou Med Ctr, Dept Nucl Med, Tao Yuan 333, Taiwan
[4] Chang Gung Mem Hosp, Linkou Med Ctr, Dept Pathol, Tao Yuan 333, Taiwan
[5] Chang Gung Mem Hosp, Linkou Med Ctr, Dept Radiat Oncol, Tao Yuan 333, Taiwan
[6] Chang Gung Univ, Grad Inst Clin Med Sci, Tao Yuan, Taiwan
关键词
CARCINOMA; METAANALYSIS; COEFFICIENT; IMAGES; PLAIN; ECHO;
D O I
10.1148/radiol.2503080874
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the diagnostic accuracy of fused T2-weighted and high-b-value diffusion-weighted (DW) magnetic resonance (MR) images at 3 T for evaluation of myometrial invasion in patients with endometrial cancer. Materials and Methods: Institutional review board approval and informed consent were obtained. From May 2006 to October 2007, 48 consecutive patients aged 25-80 years (mean age, 57 years) who had endometrial cancer were prospectively enrolled for preoperative evaluation by using a 3-T MR unit. Two radiologists interpreted the depth of myometrial invasion on T2-weighted images, dynamic contrast material-enhanced MR images, and fused T2-weighted and DW MR images (b = 1000 sec/mm(2)). Statistical methods included kappa statistics for reader agreement, Pearson analysis for pathologic correlation, accuracy assessment, and receiver operating characteristic analysis for diagnostic performance comparison. Surgical pathologic findings were the reference standard. Results: Reader agreement was excellent for fused T2-weighted and DW images (weighted kappa, 0.79), with a significant pathologic correlation regarding the depth of myometrial invasion (r = 0.94, P < .0001). For assessing any myometrial involvement, addition of fused T2-weighted and DW imaging to dynamic contrast-enhanced or dynamic contrast-enhanced and T2-weighted imaging was significantly better compared with dynamic contrast-enhanced imaging alone (P < .001) or dynamic contrast- enhanced and T2-weighted (P = .001) imaging; T2-weighted imaging combined with fused T2-weighted and DW imaging also was better than dynamic contrast- enhanced and T2-weighted imaging (P < .001). Tumor apparent diffusion coefficients were 0.60-1.32 x 10(-3) mm(2)/sec (median, 0.75 x 10(-3) mm(2)/sec), with no significant correlation with the depth of myometrial invasion (P = .31, r = -0.15). Conclusion: Fused T2-weighted and high-b-value DW images at 3 T can provide accurate information for preoperative evaluation of myometrial invasion. (c) RSNA, 2009
引用
收藏
页码:784 / 792
页数:9
相关论文
共 50 条
  • [2] Diffusion-weighted Imaging Improves the Diagnostic Accuracy of Conventional 3.0-T Breast MR Imaging
    El Khouli, Riham H.
    Jacobs, Michael A.
    Mezban, Sarah D.
    Huang, Peng
    Kamel, Ihab R.
    Macura, Katarzyna J.
    Bluemke, David A.
    RADIOLOGY, 2010, 256 (01) : 64 - 73
  • [3] Myometrial invasion in endometrial cancer: diagnostic performance of diffusion-weighted MR imaging at 1.5-T
    Gilda Rechichi
    Stefania Galimberti
    Mauro Signorelli
    Patrizia Perego
    Maria Grazia Valsecchi
    Sandro Sironi
    European Radiology, 2010, 20 : 754 - 762
  • [4] Myometrial invasion in endometrial cancer: diagnostic performance of diffusion-weighted MR imaging at 1.5-T
    Rechichi, Gilda
    Galimberti, Stefania
    Signorelli, Mauro
    Perego, Patrizia
    Valsecchi, Maria Grazia
    Sironi, Sandro
    EUROPEAN RADIOLOGY, 2010, 20 (03) : 754 - 762
  • [5] Diagnostic accuracy of ultra-high-b-value 3.0-T diffusion-weighted MR imaging for detection of prostate cancer
    Ohgiya, Yoshimitsu
    Suyama, Jumpei
    Seino, Noritaka
    Hashizume, Takashi
    Kawahara, Masaaki
    Sai, Syouei
    Saiki, Makoto
    Munechika, Jiro
    Hirose, Masanori
    Gokan, Takehiko
    CLINICAL IMAGING, 2012, 36 (05) : 526 - 531
  • [6] Endometrial cancer with cervical stromal invasion: diagnostic accuracy of diffusion-weighted and dynamic contrast enhanced MR imaging at 3T
    Lin, Gigin
    Huang, Yu-Ting
    Chao, Angel
    Lin, Yu-Chun
    Yang, Lan-Yan
    Wu, Ren-Chin
    Lu, Hsin-Ying
    Ng, Shu-Hang
    Ng, Koon-Kwan
    Lai, Chyong-Huey
    EUROPEAN RADIOLOGY, 2017, 27 (05) : 1867 - 1876
  • [7] Endometrial cancer with cervical stromal invasion: diagnostic accuracy of diffusion-weighted and dynamic contrast enhanced MR imaging at 3T
    Gigin Lin
    Yu-Ting Huang
    Angel Chao
    Yu-Chun Lin
    Lan-Yan Yang
    Ren-Chin Wu
    Hsin-Ying Lu
    Shu-Hang Ng
    Koon-Kwan Ng
    Chyong-Huey Lai
    European Radiology, 2017, 27 : 1867 - 1876
  • [8] Endometrial Cancer: Combined MR Volumetry and Diffusion-weighted Imaging for Assessment of Myometrial and Lymphovascular Invasion and Tumor Grade
    Nougaret, Stephanie
    Reinhold, Caroline
    Alsharif, Shaza S.
    Addley, Helen
    Arceneau, Jocelyne
    Molinari, Nicolas
    Guiu, Boris
    Sala, Evis
    RADIOLOGY, 2015, 276 (03) : 797 - 808
  • [9] Evaluation of Treatment Response of Chemoembolization in Hepatocellular Carcinoma with Diffusion-Weighted Imaging on 3.0-T MR Imaging
    Sahin, Hilal
    Harman, Mustafa
    Cinar, Celal
    Bozkaya, Halil
    Parildar, Mustafa
    Elmas, Nevra
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2012, 23 (02) : 241 - 247
  • [10] The Fusion of T2 Weighted MRI and Diffusion-Weighted Imaging in Evaluating the Depth of Myometrial Invasion in Endometrial Cancer