Improvement of the bone-screw interface strength with hydroxyapatite-coated and titanium-coated AO/ASIF cortical screws

被引:36
|
作者
Moroni, A [1 ]
Faldini, C [1 ]
Rocca, M [1 ]
Stea, S [1 ]
Giannini, S [1 ]
机构
[1] Univ Bologna, Rizzoli Inst, Dept Orthopaed Surg, I-40136 Bologna, Italy
关键词
AO/ASIF screws; fixation; hydroxyapatite; titanium; stainless steel;
D O I
10.1097/00005131-200204000-00007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Objective: To evaluate whether coating AO/ASIF screws with osteoconductive materials can improve bone-screw fixation. Design: Ninety-six AO/ASIF 4.5-millimeter cortical screws were divided into four paired groups and implanted in the femurs and tibiae of six sheep: Group A = standard stainless steel screws; Group B = stainless steel screws coated with highly crystalline hydroxyapatite; Group C = stainless steel screws coated with low crystalline hydroxyapatite; Group D = titanium screws coated with titanium. The screws were implanted according to the standard AO technique to an insertion torque of 2,000 Newton-millimeters. Sheep were killed at one, three, and twelve months after surgery. Main Outcome Measures: Extraction torque was measured on six screws from each group selected at random at time of each euthanization. Morphologic analysis of the bone-screw interface was performed on the remaining screws. Results: At each euthanization the extraction torque of Group A was lower than that of the other groups (p < 0.0001). At three and twelve months the extraction torque of Group B was higher than that of Group D (p = 0.002). Morphologic results showed extensive bone-screw gap in Group A. Optimal osteointegration was observed in Groups B and C. Osteointegration of Group D was higher than that of Group A and lower than that of Groups B and C. Conclusions: It was demonstrated that AO/ASIF screws coated with osteoconductive materials achieve optimal fixation strength, even in the early phase. This fixation strength was significantly higher than that of the standard screws.
引用
收藏
页码:257 / 263
页数:7
相关论文
共 50 条
  • [1] BIOMECHANICAL AND HISTOLOGICAL-EVALUATION OF HYDROXYAPATITE-COATED AO/ASIF SCREWS
    DAVID, A
    POMMER, A
    EITENMULLER, J
    MUHR, G
    UNFALLCHIRURG, 1993, 96 (01): : 12 - 17
  • [2] Biological assessment of the bone-screw interface after insertion of uncoated and hydroxyapatite-coated pedicular screws in the osteopenic sheep
    Fini, M
    Giavaresi, G
    Greggi, T
    Martini, L
    Aldini, NN
    Parisini, P
    Giardino, R
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2003, 66A (01) : 176 - 183
  • [3] Biomechanical and histomorphometric study of the bone-screw interface of calcium pyrophosphate coated titanium screws
    Lee, JH
    Ryu, HS
    Lee, DS
    Hong, KS
    Chang, BS
    Lee, CK
    BIOCERAMICS 17, 2005, 284-286 : 219 - 222
  • [4] Biomechanical and histomorphometric study on the bone-screw interface of bioactive ceramic-coated titanium screws
    Lee, JH
    Ryu, HS
    Lee, DS
    Hong, KS
    Chang, BS
    Lee, CK
    BIOMATERIALS, 2005, 26 (16) : 3249 - 3257
  • [5] MECHANICAL AND HISTOLOGICAL-EVALUATION OF HYDROXYAPATITE-COATED AO ASIF SCHANZ SCREWS FOR EXTERNAL FIXATION - AN ANIMAL-MODEL
    DAVID, A
    POMMER, A
    EITENMULLER, J
    MUHR, G
    HAHN, MP
    UNFALLCHIRURG, 1994, 97 (08): : 391 - 398
  • [6] COMPARISON OF BONE-IMPLANT INTERFACE SHEAR-STRENGTH OF SOLID HYDROXYAPATITE AND HYDROXYAPATITE-COATED TITANIUM IMPLANTS
    HAYASHI, K
    INADOME, T
    MASHIMA, T
    SUGIOKA, Y
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH, 1993, 27 (05): : 557 - 563
  • [7] INTERFACE BETWEEN BONE TISSUE AND IMPLANTS OF SOLID HYDROXYAPATITE OR HYDROXYAPATITE-COATED TITANIUM IMPLANTS
    DELANGE, GL
    DONATH, K
    BIOMATERIALS, 1989, 10 (02) : 121 - 125
  • [8] Microstructural analysis of implant-bone interface of hydroxyapatite-coated and uncoated Schanz screws
    Cimerman, M
    Cör, A
    Ceh, M
    Kristan, A
    Pizem, J
    Tonin, M
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2005, 16 (07) : 627 - 634
  • [9] Microstructural analysis of implant-bone interface of hydroxyapatite-coated and uncoated Schanz screws
    M. Cimerman
    A. Cör
    M. Čveh
    A. Kristan
    J. Pižvem
    M. Tonin
    Journal of Materials Science: Materials in Medicine, 2005, 16 : 627 - 634
  • [10] Hydroxyapatite-coated screws provide better fixation in osteoporotic bone
    Moroni, A
    Faldini, C
    Pegreffi, F
    Giannini, S
    OSTEOPOROSIS INTERNATIONAL, 2002, 13 : S7 - S7